ASTM F2537-2006(2017) Standard Practice for Calibration of Linear Displacement Sensor Systems Used to Measure Micromotion《测量微动用线性位移传感器系统校准的标准实施规程》.pdf
《ASTM F2537-2006(2017) Standard Practice for Calibration of Linear Displacement Sensor Systems Used to Measure Micromotion《测量微动用线性位移传感器系统校准的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM F2537-2006(2017) Standard Practice for Calibration of Linear Displacement Sensor Systems Used to Measure Micromotion《测量微动用线性位移传感器系统校准的标准实施规程》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F2537 06 (Reapproved 2017)Standard Practice forCalibration of Linear Displacement Sensor Systems Used toMeasure Micromotion1This standard is issued under the fixed designation F2537; the number immediately following the designation indicates the year oforiginal adoption or, in the case
2、of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the procedures for calibration oflinear displacement sensors and their c
3、orresponding powersupply, signal conditioner, and data acquisition systems (lineardisplacement sensor systems) for use in measuring micromo-tion. It covers any sensor used to measure displacement thatgives an electrical voltage output that is linearly proportional todisplacement. This includes, but
4、is not limited to, linearvariable differential transformers (LVDTs) and differentialvariable reluctance transducers (DVRTs).1.2 This calibration procedure is used to determine therelationship between output of the linear displacement sensorsystem and displacement. This relationship is used to conver
5、treadings from the linear displacement sensor system intoengineering units.1.3 This calibration procedure is also used to determine theerror of the linear displacement sensor system over the range ofits use.1.4 The values stated in SI units are to be regarded asstandard. No other units of measuremen
6、t are included in thisstandard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety, health, and environmental practices and deter-mine the applicability of regu
7、latory limitations prior to use.1.6 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade O
8、rganization TechnicalBarriers to Trade (TBT) Committee.2. Terminology2.1 Definitions:2.1.1 calibrated range, ndistance over which the lineardisplacement sensor system is calibrated.2.1.2 calibration certificate, ncertification that the sensormeets indicated specifications for its particular grade or
9、 modeland whose accuracy is traceable to the National Institute ofStandards and Technology or another international standard.2.1.3 core, ncentral rod that moves in and out of thesensor.NOTE 1It is preferable that the sensors prevent the core from exitingthe sensor housing.2.1.4 data acquisition syst
10、em, nsystem generally consist-ing of a terminal block, data acquisition card, and computerthat acquires electrical signals and allows them to be capturedby a computer.2.1.5 differential variable reluctance transducer (DVRT),na linear displacement sensor made of a sensor housing anda core. The sensor
11、 housing contains a primary coil and asecondary coil. Core position is detected by measuring thecoils differential reluctance.2.1.6 linear displacement sensor, nan electrical sensorthat converts linear displacement to electrical output.2.1.7 linear displacement sensor system, na system con-sisting o
12、f a linear displacement sensor, power supply, signalconditioner, and data acquisition system.2.1.8 linear variable differential transformer (LVDT), nalinear displacement sensor made of a sensor housing and acore. The sensor housing contains a primary coil and twosecondary coils. When an ac excitatio
13、n signal is applied to theprimary coil, voltages are induced in the secondary coils. Themagnetic core provides the magnetic flux path linking theprimary and secondary coils. Since the two voltages are ofopposite polarity, the secondary coils are connected in seriesopposing in the center, or null pos
14、ition. When the core isdisplaced from the null position, an electromagnetic imbalanceoccurs. This imbalance generates a differential ac outputvoltage across the secondary coils, which is linearly propor-tional to the direction and magnitude of the displacement.When the core is moved from the null po
15、sition, the inducedvoltage in the secondary coil, toward which the core is moved,increases while the induced voltage in the opposite secondarycoil decreases.1This practice is under the jurisdiction ofASTM Committee F04 on Medical andSurgical Materials and Devices and is the direct responsibility of
16、SubcommitteeF04.15 on Material Test Methods.Current edition approved Dec. 15, 2017. Published January 2018. Originallyapproved in 2006. Last previous edition approved in 2011 as F2537 06(2011).DOI: 10.1520/F2537-06R17.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocke
17、n, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organizat
18、ion Technical Barriers to Trade (TBT) Committee.12.1.9 null position, nthe core position within the sensorhousing where the sensor voltage output is zero (some sensorsdo not have a null position).2.1.10 offset correction, nremoval of any offset in asensors output so that at zero displacement, zero v
19、oltage isrecorded.2.1.11 percent error, nthe difference between a measure-ment of a reference standard and the actual length of thereference standard divided by the actual length of the referencestandard and the result converted to a percent.2.1.12 power supply, na regulated voltage source withoutpu
20、t equal to that required by the sensor for proper operation.2.1.13 sensor housing, ncentral hole in a linear displace-ment sensor that senses movement of the core within it.2.1.14 signal conditioner, nelectronic equipment that actsto convert the raw electrical output from the linear displace-ment se
21、nsor into a more useful signal by amplification andfiltering.3. Summary of Practice3.1 A linear displacement sensor is mounted in a calibrationfixture such that it can be subjected to a precise, knowndisplacement.3.2 Displacement is applied in steps over the full range ofthe linear displacement sens
22、or and electrical readings (forexample, voltages) are collected using the linear displacementsensor system.3.3 Each voltage reading is taken as the average of 100readings over 0.1 s, decreasing the error of the reading. Theerror in the readings is recorded as the standard deviation in thereadings. T
23、his error should be constant and independent ofdisplacement. It should be noted that the error in the readingsis a summation of errors in each of the linear displacementsensor system components.3.4 The calibration factor (S) is calculated as the slope ofthe voltage versus displacement curve using li
24、near regression.3.5 Linearity of the sensor is assessed.3.6 The percent error is determined for each calibrationpoint collected. This percent error is evaluated together withthe tolerance of the micrometer head calibration.4. Significance and Use4.1 Linear displacement sensor systems play an importa
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF253720062017STANDARDPRACTICEFORCALIBRATIONOFLINEARDISPLACEMENTSENSORSYSTEMSUSEDTOMEASUREMICROMOTION

链接地址:http://www.mydoc123.com/p-538941.html