ASTM F2510 F2510M-2017 Standard Specification for Resilient Connectors Between Reinforced Concrete Manhole Structures and Corrugated Dual- and Triple-Wall Polyethylene and Polyprop.pdf
《ASTM F2510 F2510M-2017 Standard Specification for Resilient Connectors Between Reinforced Concrete Manhole Structures and Corrugated Dual- and Triple-Wall Polyethylene and Polyprop.pdf》由会员分享,可在线阅读,更多相关《ASTM F2510 F2510M-2017 Standard Specification for Resilient Connectors Between Reinforced Concrete Manhole Structures and Corrugated Dual- and Triple-Wall Polyethylene and Polyprop.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F2510/F2510M 07 (Reapproved 2013)F2510/F2510M 17 An American National StandardStandard Specification forResilient Connectors Between Reinforced Concrete ManholeStructures and Corrugated High Density PolyethyleneDrainage Dual- and Triple-Wall Polyethylene andPolypropylene Pipes1This stan
2、dard is issued under the fixed designation F2510/F2510M; the number immediately following the designation indicates the yearof original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an
3、 editorial change since the last revision or reapproval.1. Scope Scope*1.1 This specification covers the design, material, and minimum performance requirements of resilient connectors used forconnections between reinforced concrete structures conforming to Specifications C478 and C913 to annular cor
4、rugated profile wallhigh density polyethylene (HDPE) drainage and sewer pipe conforming to AASHTO M252 or SpecificationM252, M294, andM330 or Specifications F2306/F2306M, F2648/F2648M, F2736, F2763, F2764/F2764M, and F2947/F2947M.1.1.1 These connectors are designed to provide a positive seal between
5、 the pipe and manholes or other structures subjected tointernal and external hydrostatic pressures less than 10.8 psi 74 KPa.1.1.2 Testing under this standard is limited to hydrostatic pressures. Alternate air and vacuum pressure testing involve uniquetesting protocols and are not addressed under th
6、is standard.1.1.3 Testing under this standard is conducted in a laboratory as a proof of design certification.Actual field performance testingwould be accomplished and accepted under individual project performance standards or pipeline acceptance criteria, which isoutside the scope of this standard.
7、NOTE 1Infiltration or exfiltration quantities for an installed system are dependent upon many factors other than the connections between manholestructures and pipe, and allowable quantities must be covered by other specifications and suitable testing of the installed pipeline and system.NOTE 2This s
8、pecification may be applied to other types of plastic drainage pipe. Consult with manufacturer of pipe for applicability to this standard.1.2 The values stated in either inch-pound units or SI units are to be regarded separately as standard. Within the text the SI unitsare shown in brackets. The val
9、ues stated in each system may not be exact equivalents: therefore, each system shall be usedindependently of the other. Combining values from the two systems may result in non-conformance with the standard.1.3 The following precautionary caveat pertains only to the test methods portion, Section 7. T
10、his standard does not purport toaddress all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establishappropriate safety safety, health, and healthenvironmental practices and determine the applicability of regulatory limitations priort
11、o use. For a specific precaution statement, see 7.2.3.1.4 This international standard was developed in accordance with internationally recognized principles on standardizationestablished in the Decision on Principles for the Development of International Standards, Guides and Recommendations issuedby
12、 the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2A493 Specification for Stainless Steel Wire and Wire Rods for Cold Heading and Cold ForgingA666 Specification for Annealed or Cold-Worked Austenitic Stainless Steel Sheet, Strip, Plat
13、e, and Flat BarC478 Specification for Circular Precast Reinforced Concrete Manhole SectionsC822 Terminology Relating to Concrete Pipe and Related ProductsC913 Specification for Precast Concrete Water and Wastewater StructuresD624 Test Method for Tear Strength of Conventional Vulcanized Rubber and Th
14、ermoplastic Elastomers1 This specification is under the jurisdiction of ASTM Committee F17 on Plastic Piping Systems and is the direct responsibility of Subcommittee F17.20 on Joining.Current edition approved Feb. 1, 2013Dec. 1, 2017. Published February 2013.February 2018. Originally approved in 200
15、6. Last previous edition approved in 20072013as F2510/F2510M07. 07 (2013). DOI: 10.1520/F2510_F2510M-07R13.10.1520/F2510_F2510M-17.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume informat
16、ion, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depic
17、t all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM Internationa
18、l, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1D746 Test Method for Brittleness Temperature of Plastics and Elastomers by ImpactD1566 Terminology Relating to RubberF412 Terminology Relating to Plastic Piping SystemsF477 Specification for Elastomeric Seals (Gas
19、kets) for Joining Plastic PipeF2306/F2306M Specification for 12 to 60 in. 300 to 1500 mm Annular Corrugated Profile-Wall Polyethylene (PE) Pipe andFittings for Gravity-Flow Storm Sewer and Subsurface Drainage ApplicationsF2648/F2648M Specification for 2 to 60 inch 50 to 1500 mm Annular Corrugated Pr
20、ofile Wall Polyethylene (PE) Pipe andFittings for Land Drainage ApplicationsF2736 Specification for 6 to 30 in. (152 To 762 mm) Polypropylene (PP) Corrugated Single Wall Pipe And Double Wall PipeF2763 Specification for 12 to 60 in. 300 to 1500 mm Dual and Triple Profile-Wall Polyethylene (PE) Pipe a
21、nd Fittings forSanitary Sewer ApplicationsF2764/F2764M Specification for 6 to 60 in. 150 to 1500 mm Polypropylene (PP) Corrugated Double and Triple Wall Pipe andFittings for Non-Pressure Sanitary Sewer ApplicationsF2947/F2947M Specification for 150 to 1500 mm 6 to 60 in. Annular Corrugated Profile-W
22、all Polyethylene (PE) Pipe andFittings for Sanitary Sewer Applications2.2 Other Standards:3M 252M252 Standard Specification for Corrugated Polyethylene Drainage Pipe 75 to 250 mm DiameterM294 Standard Specification for Corrugated Polyethylene Pipe, 300- to 1500-mm (12- to 60-in.) DiameterM330 Standa
23、rd Specification for Polypropylene Pipe, 300- to 1500-mm (12- to 60-in.) Diameter3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 Terms relating to plastics and rubber shall be as defined in Terminologies F412 and D1566, respectively.3.1.2 Terms relating to precast concrete man
24、holes and related products shall be as defined in Terminology C822 and as modifiedin 3.2, 3.3, and 3.4.3.2 connectorthe entire assembly including resilient seals and metallic or nonmetallic mechanical devices, if any, usedtherein.3.3 pipethe inlet or outlet pipe connected to the manhole.3.4 pipe stu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF2510F2510M2017STANDARDSPECIFICATIONFORRESILIENTCONNECTORSBETWEENREINFORCEDCONCRETEMANHOLESTRUCTURESANDCORRUGATEDDUALANDTRIPLEWALLPOLYETHYLENEANDPOLYPROPPDF

链接地址:http://www.mydoc123.com/p-538885.html