ASTM F2462-2005 Standard Practice for Operation and Maintenance of Sewers with Optical Fiber Systems《带光纤系统的下水道的运行和维护的标准实施规程》.pdf
《ASTM F2462-2005 Standard Practice for Operation and Maintenance of Sewers with Optical Fiber Systems《带光纤系统的下水道的运行和维护的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM F2462-2005 Standard Practice for Operation and Maintenance of Sewers with Optical Fiber Systems《带光纤系统的下水道的运行和维护的标准实施规程》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 2462 05Standard Practice forOperation and Maintenance of Sewers with Optical FiberSystems1This standard is issued under the fixed designation F 2462; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last r
2、evision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice applies to the operation and maintenanceof sewers with a subsequent installation of optical fiber cableper Pr
3、actice F 2303.1.2 This practice applies to gravity flow storm sewers,sanitary sewers, and combined sewers.1.3 This practice does not apply to force mains, siphons orother pressurized sewers.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It i
4、s theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2F 2303 Practice for Selection of Gravity Sewers Suitable forInstallation of Optica
5、l Fiber Cable and Conduits2.2 ANSI Standard:3ANSI Z117.1-2003 Safety Requirements for ConfinedSpaces2.3 IEC Standards:4IEC 60825-1 Ed. 1.2, en 2001 Safety of Laser ProductsPart 1: Equipment Classification, Requirements and Us-ers GuideIEC 60050-731 Electrotechnical Vocabulary: Optical FiberCommunica
6、tions2.4 Federal Standard:5OSHA Regulation 29 CFR Part 1910.146 Permit-RequiredConfined Spaces3. Terminology3.1 Definitions:3.1.1 conduit, ntubing used to house optical fiber cablethat is connected to, but separate from, a sewer pipeline.3.1.2 O4.1.2 Emergency response procedures, including sewagesp
7、ill control, emergency sewer pipeline repair, and communi-cation procedures;1This practice is under the jurisdiction of ASTM Committee F36 on Technologyand Underground Utilities and is the direct responsibility of Subcommittee F36.10on Installation and Operation of Fiber Optic Cables in Existing Sew
8、ers.Current edition approved Feb. 1, 2005. Published February 2005.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM we
9、bsite.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036.4Available from the International Electrotechnical Commission, 3 rue deVaremb, P.O. Box 131, CH-1211, Geneva 20, Switzerland.5Available from U.S. Government Printing Office Superintendent
10、 of Documents,732 N. Capitol St., NW, Mail Stop: SDE, Washington, DC 20401.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.1.3 Routine sewer O sewer pipeline repairs; periodic sewerinspection; sewer pipeline cleaning;4.1.4 Routine
11、optical fiber system O4.1.5 Cable and conduit marking; and4.1.6 Worker qualification.5. Significance and Use5.1 This is intended to outline O and6.3.2.2 Where assistance by the optical fiber cable ownermay be necessary.6.4 Routine Operating Procedures:6.4.1 Notification:6.4.1.1 The sewer operator an
12、d fiber cable system ownershould notify the other entity as far in advance as possible forplanned, routine operations.6.4.1.2 Improper cable repair or maintenance proceduresmay damage the sewer or optical fiber system, creating anunsafe situation. Because of this risk, the fiber cable systemowner mu
13、st notify the sewer pipeline operator as to the natureof the intended repair or maintenance and verify whether seweroperator supervision or oversight is required during the repairor maintenance.6.4.2 Extended Duration Access (4 hours+) to Sewer Vaultsby Optical Fiber System OwnerWhen accessing a sew
14、ervault or sewer manhole, the optical fiber cable owner mustprovide the sewer pipeline operator with at least 48 hours priornotice. If re-cabling, replacing the conduit or other extendeddurations repairs are contemplated, the optical fiber systemowner must provide with that notice, written repair pr
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF24622005STANDARDPRACTICEFOROPERATIONANDMAINTENANCEOFSEWERSWITHOPTICALFIBERSYSTEMS 光纤 系统 下水道 运行 维护

链接地址:http://www.mydoc123.com/p-538769.html