ASTM F2419-2005 Standard Practice for Installation of Thick Poured Gypsum Concrete Underlayments and Preparation of the Surface to Receive Resilient Flooring《浓浆石膏混凝土衬底的安装以及承受弹性楼面的表.pdf
《ASTM F2419-2005 Standard Practice for Installation of Thick Poured Gypsum Concrete Underlayments and Preparation of the Surface to Receive Resilient Flooring《浓浆石膏混凝土衬底的安装以及承受弹性楼面的表.pdf》由会员分享,可在线阅读,更多相关《ASTM F2419-2005 Standard Practice for Installation of Thick Poured Gypsum Concrete Underlayments and Preparation of the Surface to Receive Resilient Flooring《浓浆石膏混凝土衬底的安装以及承受弹性楼面的表.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 2419 05Standard Practice forInstallation of Thick Poured Gypsum ConcreteUnderlayments and Preparation of the Surface to ReceiveResilient Flooring1This standard is issued under the fixed designation F 2419; the number immediately following the designation indicates the year oforiginal
2、adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the installation and preparation ofthe thick p
3、oured gypsum concrete underlayments over woodstructural panel subfloors in commercial structures or overconcrete floors in commercial structures and the preparation ofthe thick poured gypsum concrete underlayment surface priorto the installation of resilient flooring in commercial buildings.1.2 This
4、 practice covers the factors that are required to becontrolled while installing thick poured gypsum concreteunderlayment as a base for resilient flooring.1.3 This practice does not cover the structural adequacy ofthe wood structural panel subfloor or concrete subfloor. Thestructural integrity of ass
5、emblies is governed by local buildingcodes.1.4 This practice does not supersede in any manner the thickpoured gypsum concrete underlayment manufacturers, adhe-sive manufacturers or resilient flooring manufacturers writteninstructions. Consult the individual manufacturer for specificrecommendations.1
6、.5 Thick poured gypsum concrete underlayments are notsuitable for use on concrete slabs on ground due to potentialmoisture problems arising from moisture intrusion, unless anadequate vapor retarder or vapor barrier is present directlybeneath the concrete subfloor.1.6 The values stated in inch-pound
7、units are to be regardedas standard. The values stated in parentheses are approximatemathematical conversions to SI units, which are provided forinformation only.1.7 This practice may involve hazardous materials, opera-tions, and equipment. This standard does not purport toaddress all of the safety
8、concerns, if any, associated with itsuse. It is the responsibility of the user of this standard toestablish appropriate safety and health practices and deter-mine the applicability of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C 472 Test Methods for Physical Testi
9、ng of Gypsum Plas-ters and Gypsum ConcreteD 4263 Test Method for Indicating Moisture in Concrete bythe Plastic Sheet MethodF 141 Terminology Relating to Resilient Floor CoveringsF 1482 Practice for Installation and Preparation of PanelType Underlayments to Receive Resilient Flooring3. Terminology3.1
10、 DefinitionsDefinitions used in this practice shall be inaccordance with Terminology F 141.3.2 Definitions of Terms Specific to This Standard:3.2.1 fully adhered flooring, nresilient flooring which hasadhesive under the entire product, bonding it to the underlay-ment surface. F 14823.2.2 non-fully a
11、dhered flooring, nresilient flooring thatmay be loose laid, in which no adhesive is utilized, or partiallybonded to the surface of the underlayment, typically at seamsand the surrounding perimeter of the product. F 14823.2.3 subfloor, nthat wood or concrete structural layerintended to provide suppor
12、t for design loads which may receiveresilient floor coverings directly if the surface is appropriate orindirectly via an underlayment if its surface is not suitable or ifunderlayment is required by appropriate code authorities.3.2.4 gypsum concrete underlayment, nthat layer of ma-terial, with binder
13、 content composed primarily of gypsumcement and Portland cement that is mixed with sand and water,then pumped and poured in a liquid state to be installed on orover a subfloor to provide a monolithic surface suitable toreceive resilient floor coverings.3.2.5 thick poured gypsum concrete underlayment
14、,nproducts which are installed in a liquid state over a1This practice is under the jurisdiction of ASTM Committee F06 on ResilientFloor Coverings and is the direct responsibility of Subcommittee F06.40 onPractices.Current edition approved Feb. 1, 2005. Published February 2005.2For referenced ASTM st
15、andards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken
16、, PA 19428-2959, United States.structurally sound concrete or precast subfloor at a minimum of12 in. (13 mm) or a structurally sound wood subfloor at aminimum of34 in. (19 mm) which when dry form an integralpart of the floor ceiling assembly for fire resistance and soundratings, satisfy building cod
17、es for thick poured gypsum con-crete underlayments, and provide a suitable floor surface forthe installation of resilient floor coverings.3.2.6 sound mat, na membrane installed between a struc-turally sound subfloor and a thick poured gypsum concreteunderlayment to increase sound reduction in the fl
18、oor ceilingassembly.4. Significance and Use4.1 This practice provides minimum recommendations forthe installation of thick poured gypsum concrete floor under-layments suitable to receive resilient floor coverings. Thispractice establishes the proper preparation, installation andquality control for t
19、hick poured gypsum concrete floor under-layments.4.2 Actual requirements for thick poured gypsum concreteunderlayments are generally included as part of project plans orspecifications and may vary from the recommendations setforth in this practice. Project plans or specifications, or both,shall supe
20、rsede the recommendations set forth in this practice.5. Product Requirements5.1 For the purposes of this practice, thick poured gypsumconcrete underlayment shall be compounds consisting prima-rily of a mixture of gypsum cement, Portland cement and sand.5.2 When tested in accordance with Test Methods
21、 C 472,thick poured gypsum concrete underlayment shall have aminimum compressive strength of 2000 psi (13.8 MPa) for useover wood subfloor and 3000 psi (20.7 MPa) for use overconcrete subfloors.5.3 When tested in accordance with Test Methods C 472,the density shall be a minimum of 105 pcf (1680 kg/m
22、).6. Storage and Handling of Thick Poured GypsumConcrete Underlayments6.1 Thick poured gypsum concrete underlayments includedin this practice are typically delivered to the jobsites as drypowder in bags on pallets. Product shall be delivered inoriginal, unopened, undamaged bags with identification l
23、abelsintact. Bags and the enclosed material should not be damagedand should be protected from the elements after delivery to thejobsite. To avoid damage, bring raw materials to the jobsite justprior to the time it will be needed.37. General Guidelines7.1 Recommended thickness of thick poured gypsum
24、con-crete over structurally sound wood is34 in. (19 mm) minimum.Recommended minimum thickness over structurally soundconcrete or precast concrete is12 in. (13 mm). Minimumthickness over a floor ceiling assembly which contains a soundmat shall be 1 in. (25 mm). Subfloor must support design loadswith
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF24192005STANDARDPRACTICEFORINSTALLATIONOFTHICKPOUREDGYPSUMCONCRETEUNDERLAYMENTSANDPREPARATIONOFTHESURFACETORECEIVERESILIENTFLOORING

链接地址:http://www.mydoc123.com/p-538659.html