ASTM F2326-2004 Standard Test Method for Collection and Analysis of Visible Emissions from Candles as They Burn《蜡烛燃烧时可视排放物的采集和分析的标准试验方法》.pdf
《ASTM F2326-2004 Standard Test Method for Collection and Analysis of Visible Emissions from Candles as They Burn《蜡烛燃烧时可视排放物的采集和分析的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F2326-2004 Standard Test Method for Collection and Analysis of Visible Emissions from Candles as They Burn《蜡烛燃烧时可视排放物的采集和分析的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 2326 04Standard Test Method forCollection and Analysis of Visible Emissions from Candlesas They Burn1This standard is issued under the fixed designation F 2326; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the yea
2、r of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.INTRODUCTIONDuring the development of this test method with a specially manufactured “standardized” candle,variability of ca
3、ndle burn behavior was observed that introduced a wide statistical variation in theoverall test results from a single design. Variability in testing different types of candle products wouldintroduce even greater variability, that is, a pillar candle comprised of 60C (140F) melting point waxwould not
4、, and would not be expected to, show the same burn behavior as a jar candle comprised of54.4C (130F) melting point wax. It is believed that a significant database of candle burnperformance, based on each type of candle and formulation format, would be required before onecould determine whether a sta
5、tistical basis could be developed for pass/fail criteria for visible smokeemissions from candles. This method is intended to provide candle manufacturers a standardprocedure to use during the development of candle designs and formulations to compare relativesmoking/burn behavior. This method neither
6、 implies nor sets a standard level for visible smokeemissions for any candle type or formulation.1. Scope1.1 This test method covers the collection and analysis ofvisible emissions from indoor use candles as they burn.1.2 The test is to be used to compare relative smoke/burnbehavior during developme
7、nt of candle designs and formula-tions.1.3 This test method may not be suitable for multiple wickcandles; tapers and candles intended to be burned whilefloating on water commonly known as “floaters.”1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its
8、use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2F 1972 Guide for Terminology Relating to Candles andAssociated Accessory
9、ItemsPS 59 Provisional Specification for Fire Safety for Candles3. Terminology3.1 See Guide F 1972 for definitions of terms not specifiedin 3.2.3.2 Definitions:3.2.1 burn cyclelength of time the candle is burned duringone test day. For this test, a burn cycle is 4 h (see ProvisionalSpecification PS
10、59).3.2.2 burn periodtotal time the candle is burned over theduration of the test. For this test, the burn period will be 16 h.3.2.3 fuel pool establishment periodtime, 15 min orlonger, before each burn cycle that a candle must be burned toestablish a normal fuel pool and stable flame.3.2.4 molten f
11、uel poolportion of the wax or fuel pool of acandle that is in the liquid form when the candle is burning.3.2.5 optical densitometerinstrument used for determin-ing the optical density in the transmittance or reflectance mode.3.2.6 top of the candlethe upper most part of the candle orcontainer.3.2.7
12、visible emissionsemissions that can be seen oncecollected on a substrate.1This test method is under the jurisdiction of ASTM Committee F15 onConsumer Products and is the direct responsibility of Subcommittee F15.45 onCandle Products.Current edition approved Feb. 1, 2004. Published February 2004.2For
13、 referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700
14、, West Conshohocken, PA 19428-2959, United States.4. Summary of Test Method4.1 The visible emissions from a candle are collected on atransparent media over the specified burn period. The emis-sions can then be assigned a relative value as a function ofopacity using a densitometer for a given testing
15、 sequence.5. Significance and Use5.1 The intent of this test method is to aid the candlemanufacturer to optimize candle formulations in the reductionof visible smoke emissions.5.2 This test method is intended to provide candle manu-facturers a standard procedure to use during development ofcandle de
16、signs and formulations to compare relative smoke/burn behavior. For the development of this method, a protocolwas established for trimming the wick on specially preparedtest candles to 6 to 7 mm (14 in.) prior to each burn cycle. It isrecommended that the manufacturer determine a standardizedprotoco
17、l, that is, either not trimming the wick or trimming thewick to an appropriate length in order for direct comparison ofresults.5.3 A relative ranking of candle formulations can be estab-lished with the use of a histogram of the data and controlcharts.5.4 This test method is not intended to set forth
18、 pass/failcriteria for visible smoke emissions from candles, as such, thismethod sets no standard level for visible smoke emissions.6. Interferences6.1 The thickness of the collection material, that is, the glassmicroscope slide, will create a positive interference and shouldbe corrected for in the
19、set up of the densitometer prior to theanalysis of test samples.6.2 Any material that darkens the microscope slide otherthan the visible emissions of a candle shall create a positiveinterference.7. Apparatus and Materials7.1 Glass Microscope Slides, nominally 76 by 25 mm (3 by1 in.) with a writing s
20、urface for sample identification) to beplaced above the candle to collect visible emissions.7.2 Ring Stands and Clamps.7.3 Black and White Optical Densitometer.7.4 Transparent Step Gray Scales, for the verification ofcalibration of the densitometer.7.5 Number 1.5 Cover Slips.7.6 Transparent Single-s
21、ided Tape.7.7 Lint Free Cloth, or wipe material.7.8 Room or Area, with minimum drafts for burningcandles.7.9 Noncombustible Surface, on which to test candles.7.10 Ruler, or similar measuring device capable of measur-ing to the nearest millimetre.7.11 Thermometers or Temperature Monitoring Device, ac
22、-curate to 61C.7.12 Scissors, or other device suitable for trimming wicksbetween burn cycles.8. Preparation of Apparatus8.1 Prior to sampling, wipe microscope slides with a suit-able lint free wipe to remove dust or fingerprints, or both.8.2 Attach the microscope slide in a flat horizontal positioni
23、n a ring stand clamp. The microscope slide should be parallelwith the ground and as close to level as possible.8.3 Place the candle(s) to be tested in a chamber or roomwith minimal drafts on a level-burning surface. The tempera-ture of the room or chamber shall be maintained to 25 6 5C(77 6 9F) thro
24、ughout the test period.8.4 Move the microscope slide with ring stand into positionsuch that the center of the microscope slide is above the centerof the wick in the candle.8.5 Position the microscope slide in the ring stand such thatit is 102 6 6mm(46 0.25 in.) above the solid top surface ofthe cand
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便