《ASTM F2286-2016 Standard Design and Performance Specification for Removable Mesh Fencing for Swimming Pools Hot Tubs and Spas《游泳池 热浴桶和水疗用可拆卸网状围栏的标准设计和性能规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM F2286-2016 Standard Design and Performance Specification for Removable Mesh Fencing for Swimming Pools Hot Tubs and Spas《游泳池 热浴桶和水疗用可拆卸网状围栏的标准设计和性能规范》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F2286 05 (Reapproved 2013)F2286 16Standard Design and Performance Specification forRemovable Mesh Fencing for Swimming Pools, Hot Tubs,and Spas1This standard is issued under the fixed designation F2286; the number immediately following the designation indicates the year oforiginal adopt
2、ion or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification outlines the performance and design requirements for r
3、emovable mesh safety barriers used for barriersfor swimming pools, hot tubs, and spas to reduce the incidence of injuries or death for infants and children up to and includingfive years of age.1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parenthes
4、es are for informationonly.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatorylimitations
5、prior to use.2. Referenced Documents2.1 ASTM Standards:2D3787 Test Method for Bursting Strength of TextilesConstant-Rate-of-Traverse (CRT) Ball Burst TestD5034 Test Method for Breaking Strength and Elongation of Textile Fabrics (Grab Test)F1908 Guide for Fences for Residential Outdoor Swimming Pools
6、, Hot Tubs, and SpasG154 Practice for Operating Fluorescent Ultraviolet (UV) Lamp Apparatus for Exposure of Nonmetallic Materials2.2 ANSI Standards:3ANSI Z97.1 Glazing Materials Used in Buildings, Safety Performance Specifications and Methods of TestANSI Z535.4 Product Safety Signs and Labels2.3 ANS
7、I/NSPI Standard:3ANSI/NSPI-8 Standard for Model Barrier Code for Residential Swimming Pools3. Terminology3.1 Definitions:3.1.1 See ANSI/NSPI-8 and Guide F1908 for specific terms.3.2 Definitions of Terms Specific to This Standard:3.2.1 grade, nsurfaces including concrete, brick, tile, wood, metal, or
8、 similar rigid surface used as foundation for mesh safetybarriers.3.2.2 mesh safety barrier, nbarrier composed of fabric mesh, support posts, hardware, and other assembly components.4. Design and Performance Requirements4.1 The top of a fence or wall used as a barrier shall be a minimum of 48 in. (1
9、.2 m) above the grade adjacent to the exteriorside of the barrier.1 This specification is under the jurisdiction of ASTM Committee F15 on Consumer Products and is the direct responsibility of Subcommittee F15.49 on Pool SafetyStandards.Current edition approved Feb. 15, 2013Jan. 1, 2016. Published Ap
10、ril 2013February 2016. Originally approved in 2005. Last previous edition approved in 20052013 asF2286 05.F2286 05 (2013). DOI: 10.1520/F2286-05R13.10.1520/F2286-16.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Boo
11、k of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3 Available from American National Standards Institute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036.This document is not an ASTM standard and is intended only to provide the user of an AS
12、TM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published
13、 by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14.2 Distance between vertical support poles and attached mesh, along with other manufactured factors, shall be so designed andfabricate
14、d to hinder childrens ability to climb.4.3 Decorative details, if provided or added, shall not afford the ability of children to climb the mesh safety barrier.4.4 When a hinged gate is used in addition to, or as part of the mesh safety barrier, the gate shall be self-closing, self-latching,accommoda
15、te a locking device and open outward from the pool, spa, or hot tub. The self-latching and lockable devices for gatesshall be located at a minimum height of 54 in. (1.37 m) above grade and be mounted on the outside of the gate. An additionalsupport or plate may be necessary to raise the device to 54
16、 in. (1.37 m).NOTE 1Hinged gates in accordance with 4.4 are recommended for use with removable mesh fencing for swimming pools, hot tubs, and spas.4.5 There shall be a clear zone of at least 20 in. (50 cm) between the barrier and pool/spa/hot tub.4.6 The fence shall have at least 40 % open space to
17、allow visibility from outside to inside of the pool area.NOTE 2The “open space” is calculated by using total area and subtracting the area of opaque supports and mesh.4.7 The mesh safety barrier shall be removable when desired.4.8 The removable mesh safety barrier, when properly installed, shall pro
18、vide continuous and constant protection of the pool/hottub/spa. When used on an outdoor or unenclosed pool, the mesh safety barrier may provide complete 360 protection or may beattached to another existing property or perimeter fence in such a manner as to prevent unsupervised access to the pool. Wh
19、en usedin a screen enclosure, the terminus of the mesh safety barrier shall be fastened to an upright or vertical member of the enclosureand installed in such a location that the barrier prevents unsupervised access to the pool.4.9 Vertical posts of the mesh safety barrier shall extend a minimum of
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF22862016STANDARDDESIGNANDPERFORMANCESPECIFICATIONFORREMOVABLEMESHFENCINGFORSWIMMINGPOOLSHOTTUBSANDSPAS

链接地址:http://www.mydoc123.com/p-538321.html