ASTM F2286-2005(2013) Standard Design and Performance Specification for Removable Mesh Fencing for Swimming Pools Hot Tubs and Spas《游泳池 热浴桶和水疗用可拆卸网状围栏的标准设计和性能规范》.pdf
《ASTM F2286-2005(2013) Standard Design and Performance Specification for Removable Mesh Fencing for Swimming Pools Hot Tubs and Spas《游泳池 热浴桶和水疗用可拆卸网状围栏的标准设计和性能规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM F2286-2005(2013) Standard Design and Performance Specification for Removable Mesh Fencing for Swimming Pools Hot Tubs and Spas《游泳池 热浴桶和水疗用可拆卸网状围栏的标准设计和性能规范》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F2286 05 (Reapproved 2013)Standard Design and Performance Specification forRemovable Mesh Fencing for Swimming Pools, Hot Tubs,and Spas1This standard is issued under the fixed designation F2286; the number immediately following the designation indicates the year oforiginal adoption or,
2、in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification outlines the performance and designrequirements for removable
3、mesh safety barriers used forbarriers for swimming pools, hot tubs, and spas to reduce theincidence of injuries or death for infants and children up to andincluding five years of age.1.2 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are fori
4、nformation only.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and to determine theapplicability of regulatory limitations prior to us
5、e.2. Referenced Documents2.1 ASTM Standards:2D3787 Test Method for Bursting Strength of TextilesConstant-Rate-of-Traverse (CRT) Ball Burst TestD5034 Test Method for Breaking Strength and Elongation ofTextile Fabrics (Grab Test)F1908 Guide for Fences for Residential Outdoor SwimmingPools, Hot Tubs, a
6、nd SpasG154 Practice for Operating Fluorescent Ultraviolet (UV)Lamp Apparatus for Exposure of Nonmetallic Materials2.2 ANSI Standards:3ANSI Z97.1 Glazing Materials Used in Buildings, SafetyPerformance Specifications and Methods of TestANSI Z535.4 Product Safety Signs and Labels2.3 ANSI/NSPI Standard
7、:3ANSI/NSPI-8 Standard for Model Barrier Code for Residen-tial Swimming Pools3. Terminology3.1 Definitions:3.1.1 SeeANSI/NSPI-8 and Guide F1908 for specific terms.3.2 Definitions of Terms Specific to This Standard:3.2.1 grade, nsurfaces including concrete, brick, tile,wood, metal, or similar rigid s
8、urface used as foundation formesh safety barriers.3.2.2 mesh safety barrier, nbarrier composed of fabricmesh, support posts, hardware, and other assembly compo-nents.4. Design and Performance Requirements4.1 The top of a fence or wall used as a barrier shall be aminimum of 48 in. (1.2 m) above the g
9、rade adjacent to theexterior side of the barrier.4.2 Distance between vertical support poles and attachedmesh, along with other manufactured factors, shall be sodesigned and fabricated to hinder childrens ability to climb.4.3 Decorative details, if provided or added, shall not affordthe ability of c
10、hildren to climb the mesh safety barrier.4.4 When a hinged gate is used in addition to, or as part ofthe mesh safety barrier, the gate shall be self-closing, self-latching, accommodate a locking device and open outwardfrom the pool, spa, or hot tub. The self-latching and lockabledevices for gates sh
11、all be located at a minimum height of 54 in.(1.37 m) above grade and be mounted on the outside of thegate. An additional support or plate may be necessary to raisethe device to 54 in. (1.37 m).NOTE 1Hinged gates in accordance with 4.4 are recommended for usewith removable mesh fencing for swimming p
12、ools, hot tubs, and spas.4.5 There shall be a clear zone of at least 20 in. (50 cm)between the barrier and pool/spa/hot tub.4.6 The fence shall have at least 40 % open space to allowvisibility from outside to inside of the pool area.NOTE 2The “open space” is calculated by using total area andsubtrac
13、ting the area of opaque supports and mesh.1This specification is under the jurisdiction of ASTM Committee F15 onConsumer Products and is the direct responsibility of Subcommittee F15.49 on PoolSafety Standards.Current edition approved Feb. 15, 2013. Published April 2013. Originallyapproved in 2005.
14、Last previous edition approved in 2005 as F2286 05. DOI:10.1520/F2286-05R13.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onth
15、e ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14.7 The mesh safety barrier shall be removable whendesired.4.8 T
16、he removable mesh safety barrier, when properlyinstalled, shall provide continuous and constant protection ofthe pool/hot tub/spa. When used on an outdoor or unenclosedpool, the mesh safety barrier may provide complete 360protection or may be attached to another existing property orperimeter fence i
17、n such a manner as to prevent unsupervisedaccess to the pool. When used in a screen enclosure, theterminus of the mesh safety barrier shall be fastened to anupright or vertical member of the enclosure and installed insuch a location that the barrier prevents unsupervised access tothe pool.4.9 Vertic
18、al posts of the mesh safety barrier shall extend aminimum of 3 in. (7.5 cm) below grade level and shall bespaced no greater than 40 in. (1.016 m) apart.4.10 The mesh used in the barrier shall have a minimumtensile strength according to Test Method D5034 of 100 lbf(449 N) and a minimum burst strength
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF228620052013STANDARDDESIGNANDPERFORMANCESPECIFICATIONFORREMOVABLEMESHFENCINGFORSWIMMINGPOOLSHOTTUBSANDSPAS

链接地址:http://www.mydoc123.com/p-538320.html