ASTM F2286-2005 Standard Design and Performance Specification for Removable Mesh Fencing for Swimming Pools Hot Tubs and Spas《游泳池、热浴桶和水疗用可拆卸网状围栏的标准设计和性能规范》.pdf
《ASTM F2286-2005 Standard Design and Performance Specification for Removable Mesh Fencing for Swimming Pools Hot Tubs and Spas《游泳池、热浴桶和水疗用可拆卸网状围栏的标准设计和性能规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM F2286-2005 Standard Design and Performance Specification for Removable Mesh Fencing for Swimming Pools Hot Tubs and Spas《游泳池、热浴桶和水疗用可拆卸网状围栏的标准设计和性能规范》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 2286 05Standard Design and Performance Specification forRemovable Mesh Fencing for Swimming Pools, Hot Tubs,and Spas1This standard is issued under the fixed designation F 2286; the number immediately following the designation indicates the year oforiginal adoption or, in the case of r
2、evision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification outlines the performance and designrequirements for removable mesh safety bar
3、riers used forbarriers for swimming pools, hot tubs, and spas to reduce theincidence of injuries or death for infants and children up to andincluding five years of age.1.2 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are forinformation only
4、.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and to determine theapplicability of regulatory limitations prior to use.2. Referenced
5、 Documents2.1 ASTM Standards:2D 3787 Test Method for Bursting Strength of TextilesConstant-Rate-of-Traverse (CRT) Ball Burst TestD 5034 Test Method for Breaking Strength and Elongationof Textile Fabrics (Grab Test)F 1908 Guide for Fences for Residential Outdoor Swim-ming Pools, Hot Tubs, and SpasG 1
6、54 Practice for Operating Fluorescent Light Apparatusfor UV Exposure of Nonmetallic Materials2.2 ANSI Standards:3ANSI Z97.1 Glazing Materials Used in Buildings, SafetyPerformance Specifications and Methods of TestANSI Z535.4 Product Safety Signs and Labels2.3 ANSI/NSPI Standard:3ANSI/NSPI-8 Standard
7、 for Model Barrier Code for Resi-dential Swimming Pools3. Terminology3.1 Definitions:3.1.1 See ANSI/NSPI-8 and Guide F 1908 for specificterms.3.2 Definitions of Terms Specific to This Standard:3.2.1 grade, nsurfaces including concrete, brick, tile,wood, metal, or similar rigid surface used as founda
8、tion formesh safety barriers.3.2.2 mesh safety barrier, nbarrier composed of fabricmesh, support posts, hardware, and other assembly compo-nents.4. Design and Performance Requirements4.1 The top of a fence or wall used as a barrier shall be aminimum of 48 in. (1.2 m) above the grade adjacent to thee
9、xterior side of the barrier.4.2 Distance between vertical support poles and attachedmesh, along with other manufactured factors, shall be sodesigned and fabricated to hinder childrens ability to climb.4.3 Decorative details, if provided or added, shall not affordthe ability of children to climb the
10、mesh safety barrier.4.4 When a hinged gate is used in addition to, or as part ofthe mesh safety barrier, the gate shall be self-closing, self-latching, accommodate a locking device and open outwardfrom the pool, spa, or hot tub. The self-latching and lockabledevices for gates shall be located at a m
11、inimum height of 54 in.(1.37 m) above grade and be mounted on the outside of thegate. An additional support or plate may be necessary to raisethe device to 54 in. (1.37 m).NOTE 1Hinged gates in accordance with 4.4 are recommended for usewith removable mesh fencing for swimming pools, hot tubs, and s
12、pas.4.5 There shall be a clear zone of at least 20 in. (50 cm)between the barrier and pool/spa/hot tub.4.6 The fence shall have at least 40 % open space to allowvisibility from outside to inside of the pool area.NOTE 2The “open space” is calculated by using total area andsubtracting the area of opaq
13、ue supports and mesh.4.7 The mesh safety barrier shall be removable whendesired.1This specification is under the jurisdiction of ASTM Committee F15 onConsumer Products and is the direct responsibility of Subcommittee F15.49 on PoolSafety Standards.Current edition approved Jan. 1, 2005. Published Jan
14、uary 2005.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institu
15、te (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.8 The removable mesh safety barrier, when properlyinstalled, shall provide continuous and constant protection ofthe pool/hot tu
16、b/spa. When used on an outdoor or unenclosedpool, the mesh safety barrier may provide complete 360protection or may be attached to another existing property orperimeter fence in such a manner as to prevent unsupervisedaccess to the pool. When used in a screen enclosure, theterminus of the mesh safet
17、y barrier shall be fastened to anupright or vertical member of the enclosure and installed insuch a location that the barrier prevents unsupervised access tothe pool.4.9 Vertical posts of the mesh safety barrier shall extend aminimum of 3 in. (7.5 cm) below grade level and shall bespaced no greater
18、than 40 in. (1.016 m) apart.4.10 The mesh used in the barrier shall have a minimumtensile strength according to Test Method D 5034 of 100 lbf(449 N) and a minimum burst strength in accordance with TestMethod D 3787 of 150 lbf (667 N).4.11 The mesh shall receive a descriptive performancerating of no
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF22862005STANDARDDESIGNANDPERFORMANCESPECIFICATIONFORREMOVABLEMESHFENCINGFORSWIMMINGPOOLSHOTTUBSANDSPAS

链接地址:http://www.mydoc123.com/p-538319.html