ASTM F2227-2013 Standard Test Method for Non-Destructive Detection of Leaks in Non-sealed and Empty Packaging Trays by CO2 Tracer Gas Method《采用二氧化碳示踪气体法对未密封及空的包装托盘的泄漏性进行无损检测的标准试验方法.pdf
《ASTM F2227-2013 Standard Test Method for Non-Destructive Detection of Leaks in Non-sealed and Empty Packaging Trays by CO2 Tracer Gas Method《采用二氧化碳示踪气体法对未密封及空的包装托盘的泄漏性进行无损检测的标准试验方法.pdf》由会员分享,可在线阅读,更多相关《ASTM F2227-2013 Standard Test Method for Non-Destructive Detection of Leaks in Non-sealed and Empty Packaging Trays by CO2 Tracer Gas Method《采用二氧化碳示踪气体法对未密封及空的包装托盘的泄漏性进行无损检测的标准试验方法.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F2227 02 (Reapproved 2007)F2227 13Standard Test Method forNon-Destructive Detection of Leaks in Non-sealed andEmpty Medical Packaging Trays by CO2 Tracer Gas Method1This standard is issued under the fixed designation F2227; the number immediately following the designation indicates the
2、year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This non-destructive test method detects pinhole lea
3、ks in trays, as small as 50 m (0.002 in.) in diameter, or equivalentlysized cracks, subject to trace gas concentration in the tray, tray design and manufacturing tolerances.1.2 The values stated in SI units are to be regarded as standard units. Values in parentheses are for information only.1.3 This
4、 standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.
5、1 ASTM Standards:2D996 Terminology of Packaging and Distribution EnvironmentsF1327 Terminology Relating to Barrier Materials for Medical Packaging (Withdrawn 2007)33. Terminology3.1 General Term DefinitionsFor definitions used in this test method, see Terminologies D996 and F1327, Sections 3.3.2 Def
6、initions of Terms Specific to This Standard:3.2.1 trace gasa compound selected solely for use to identify leakage flow.4. Summary of Test Method4.1 This test method utilizes CO2 sensing techniques in the detection of a CO2 trace gas to quantify leaks in medical packagingtrays. The test method provid
7、es a qualitative (accept/reject) inspection method to evaluate trays for pinholes and cracks. Furtherinformation on the “Leak Test Theory” may be found in Annex A1.5. Significance and Use5.1 Harmful biological or particulate contaminants may enter the package through imperfections such as pinholes o
8、r cracks intrays.5.2 After initial instrument set-up and calibration, the operations of individual tests and test results do not need operatorinterpretation.5.3 Leak test results that exceed the permissible threshold setting are indicated by audible or visual signal responses, or both,or by other me
9、ans.5.4 This non-destructive test method may be performed in either laboratory or production environments and may be undertakenon either a 100 % or a statistical sampling basis. This test method, in single instrument use and current implementation, may notbe fast enough to work on a production packa
10、ging line, but is well suited for statistical testing as well as package developmentaldesign work.1 This test method is under the jurisdiction of ASTM Committee F02 on Flexible Barrier Packaging and is the direct responsibility of Subcommittee F02.40 on PackageIntegrity.Current edition approved Apri
11、l 1, 2007Aug. 1, 2013. Published May 2007September 2013. Originally approved in 2002. Last previous edition approved in 20022007 asF2227 02.F2227 02 (2007). DOI: 10.1520/F2227-02R07.10.1520/F2227-13.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service
12、at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3 The last approved version of this historical standard is referenced on www.astm.org.This document is not an ASTM standard and is intended only to provide the us
13、er of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard a
14、s published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States16. Apparatus6.1 Non-destructive Trace Gas Leak Detection ApparatusThe apparatus test fixture consists of three major element
15、s and isshown in Fig. 1.6.2 Sealing MembraneThe purpose of the membrane is to seal off the tracer gas transmission out of the top of the open tray.6.3 Control TraysCalibrated pinholes, or leaks, constructed in control trays for instrument calibration as well as for testprocedure verification.6.4 Tes
16、t FixtureApparatus, which must be designed to ensure detection of a calibrated leak.7. Preparation of Apparatus7.1 The test apparatus is to be started, warmed-up, and made ready according to the manufacturers specifications. Theinstrument must be operated in an environment as described in the instru
17、ments user manual.8. Reagents and Materials8.1 CO2 Trace Gas Cylinder and RegulatorAcylinder of “Commercial” or “Bone Dry” grade carbon dioxide with a minimumof 206.84-kPa (30-psi) pressure is required for calibration and testing.8.2 Sealing MembraneThe sealing membrane must exhibit the correct plia
18、bility and tackiness in order to form a gas-tightbond without leaving a residue on the tray-sealing surface after removal from the test fixture.9. Hazards9.1 As the test fixture is closed, it may present pinch-point hazards.9.2 CO2, although inert and non-toxic, can cause danger of suffocation if it
19、 is allowed to displace oxygen. Thus it isrecommended that the spent carbon dioxide be naturally vented away from the test area and that adequate ventilation be provided.10. Calibration and Standardization10.1 Before any measurements are made, the apparatus must be calibrated. The calibration proced
20、ure is used for overall systemcheckout, as well as to establish an initial reference profile for simulated pinhole leaks, and to determine test limits for eachdifferent tray geometry to be tested using a specific test fixture. The calibration procedure is performed to establish the sensitivitysettin
21、g of the instrumentation. It is expected that the calibration procedures be carried out frequently; typically, at least one or moretimes a day, preferably at the beginning of every shift.10.2 Refer to the instrument manufacturers operating instructions regarding preparation of Calibration Standards,
22、 Conditioningof Calibration Trays and Instrument Calibration used in establishing baseline settings.FIG. 1 Schematic of Test Fixture and Test TrayF2227 13211. Procedure11.1 Verify that sufficient CO2 trace gas is available for the tests. Monitor the trace gas supply and functionality of the gasdeliv
23、ery system.11.2 Select and implement the properly sized test fixture for the trays to be tested. Verify that the instrument and associated testfixture have been calibrated for the trays to be tested. The test fixture is too large when the instrument is unable to detect acalibrated control pinhole le
24、ak.11.3 Adjust the instrument baseline settings determined in calibration.11.4 Place the tray to be tested into the test fixture making certain that the tray is centered in the fixture and that good sealingcontact is made between the tray flange and the fixture incorporated sealing.NOTE 1The sealing
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF22272013STANDARDTESTMETHODFORNONDESTRUCTIVEDETECTIONOFLEAKSINNONSEALEDANDEMPTYPACKAGINGTRAYSBYCO2TRACERGASMETHOD

链接地址:http://www.mydoc123.com/p-538115.html