ASTM F2135-2001(2007) Standard Specification for Molded Drain Waste and Vent (DWV) Short-Pattern Plastic Fittings《模制排水、污物和通风的短型塑料配件标准规范》.pdf
《ASTM F2135-2001(2007) Standard Specification for Molded Drain Waste and Vent (DWV) Short-Pattern Plastic Fittings《模制排水、污物和通风的短型塑料配件标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM F2135-2001(2007) Standard Specification for Molded Drain Waste and Vent (DWV) Short-Pattern Plastic Fittings《模制排水、污物和通风的短型塑料配件标准规范》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 2135 01 (Reapproved 2007)An American National StandardStandard Specification forMolded Drain, Waste, and Vent (DWV) Short-Pattern PlasticFittings1This standard is issued under the fixed designation F 2135; the number immediately following the designation indicates the year oforiginal
2、adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers standard fitting geometries formolded sho
3、rt-pattern plastic fittings intended for use in drain,waste, and vent applications.1.2 Fittings meeting the requirements of this specificationare designed for use with outside-diameter controlled pipe. Thebody inside diameter can vary significantly as the wall thick-ness and outside diameter varies,
4、 and therefore, is not suitablefor use as a fitting socket.1.3 Fittings meeting the requirements of this specificationshall be tested in accordance with the applicable requirementsof Specifications D 2661 or D 2665.1.4 The values stated in inch-pound units are to be regardedas standard. The values g
5、iven in parentheses are mathematicalconversions to SI units which are provided for informationonly and are not considered standard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establi
6、sh appro-priate safety and health practices and determine the applica-bility of regulatory requirements prior to use.2. Referenced Documents2.1 ASTM Standards:2D 2122 Test Method for Determining Dimensions of Ther-moplastic Pipe and FittingsD 2661 Specification for Acrylonitrile-Butadiene-Styrene(AB
7、S) Schedule 40 Plastic Drain, Waste, and Vent Pipeand FittingsD 2665 Specification for Poly(Vinyl Chloride) (PVC) Plas-tic Drain, Waste, and Vent Pipe and FittingsD 2749 Symbols for Dimensions of Plastic Pipe FittingsF 1498 Specification for Taper Pipe Threads 60 for Ther-moplastic Pipe and Fittings
8、3. Requirements3.1 Short-pattern fittings shall conform to the geometries asspecified in this specification.3.2 All other dimensions shall be determined in accordancewith Test Method D 2122.3.3 The exact outside shape of a short-pattern fitting isdetermined by the socket dimensions, wall thickness r
9、equire-ments, waterway, and any other critical dimensions that may bespecified.3.4 Configurations designed as short as possible are accept-able providing that the minimum wall thickness requirementsfor the particular nominal size being made is followed.3.5 All short-pattern fittings used for drainag
10、e and having a90 directional change (except vent fittings) shall have a pitchof14 in./ft or 1128.3.6 All short-pattern fittings having tapered threads shallconform and be gaged in accordance with SpecificationF 1498.3.7 45 Y-Branches:3.7.1 Short-pattern 45 Y-branches shall not be pitched.3.7.1.1 Whe
11、n the branch of a short-pattern 45 Y is of asmaller diameter than the main body of the fitting, the internaldiameters of the fitting shall remain constant until theyintercept one another.3.8 One-Quarter Bends:3.8.1 Short-pattern one-quarter bends shall have a centerlineradius of curvature of not les
12、s than the nominal pipe size, withthe exception of traps. The centerline radius of curvature shallbe measured in accordance with Section 4.3.9 Sanitary Tees:3.9.1 Short-pattern sanitary tees and reducing tees shallhave a centerline radius of curvature on the side branch of notless than its nominal s
13、ize, when measured in accordance withSection 4. The alignment of the side branch shall be so locatedthat the smallest inside radius of the side branch of the sanitarytee shall meet tangentially with, or within 5 % of, the mainbore (see Fig. 1), when measured in accordance with 4.4.5.1This specificat
14、ion is under the jurisdiction of ASTM Committee F17 on PlasticPiping Systems and is the direct responsibility of Subcommittee F17.63 on DWV.Current edition approved Aug. 1, 2007. Published August 2007. Originallyapproved in 2001. Last previous edition approved in 2001 as F 213501.2For referenced AST
15、M standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshoho
16、cken, PA 19428-2959, United States.NOTE 1Refer to Appendix X1 for geometric configurations of someof the fittings being produced. Consult the individual manufacturer forlaying lengths.4. Test Method for Determining Compliance of Short-Pattern14 Bends and Sanitary Tees4.1 Scope:4.1.1 This test method
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF213520012007STANDARDSPECIFICATIONFORMOLDEDDRAINWASTEANDVENTDWVSHORTPATTERNPLASTICFITTINGS 排水 污物

链接地址:http://www.mydoc123.com/p-537831.html