ASTM F970-2007 Standard Test Method for Static Load Limit《静荷载极限的标准试验方法》.pdf
《ASTM F970-2007 Standard Test Method for Static Load Limit《静荷载极限的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F970-2007 Standard Test Method for Static Load Limit《静荷载极限的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 970 07Standard Test Method forStatic Load Limit1This standard is issued under the fixed designation F 970; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates
2、the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method is intended for use in determining therecovery properties of resilient floor covering after long-termindentation test, 24 h under the load specified
3、in the detailspecification. The reported value, residual indentation, is thedepth of the depression remaining 24 h after removal of thespecified load.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this
4、standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E 171 Specification for Atmospheres for Conditioning andTesting Flexible Barrier MaterialsE 691 Practice for Conducting an
5、 Interlaboratory Study toDetermine the Precision of a Test MethodF 386 Test Method for Thickness of Resilient FlooringMaterials Having Flat SurfacesF 387 Test Method for Measuring Thickness of ResilientFloor Covering With Foam LayerF 1914 Test Methods for Short-Term Indentation and Re-sidual Indenta
6、tion of Resilient Floor Covering3. Significance and Use3.1 This test method is a meaningful test for determining theindentation recovery properties of resilient floor covering.33.2 As testing is conducted on uninstalled flooring, resultsare not necessarily an indicator of the floor coverings install
7、edperformance.34. Apparatus4.1 The following apparatus shall be used:4.2 Conditioning Room, providing the standard laboratoryatmosphere of 50 6 5 % relative humidity at a temperature of73.4 6 3.6F (23 6 2.0C).4.3 Indentation Machine, as described in Section 12 andpictured in Fig. 2 of Test Method F
8、1914.4.4 Indentor Plates, each constructed of a piece of 2-in.(50.8 mm) square stainless steel, 0.240 6 0.005 in. (6.1 6 0.1mm) thick, with one side turned to 1.125 in. (28.6 mm) indiameter (one square inch area) to depth of 0.150 in. (3.8 mm)(see Fig. 1).4.5 Dial Micrometer, as described in Test Me
9、thod F 386when measuring resilient floor coverings containing a foamlayer as part of the construction or as described in Test MethodF 387 when measuring all other resilient floor coverings.4.6 Template of Poly(methyl Methacrylate) (PMMA), or ofother transparent material, 2 by 2 in. (50.8 by 50.8 mm)
10、 withround scratch line centered on the template that is 1.125 in.(28.58 mm) in diameter, defining the test area, and with a12 in.(12.7 mm) diameter hole at the center of the template to drawa circle on the specimen where thickness will be measured.4.7 Die, 2 by 2 in. (50.8 by 50.8 mm) and press, pa
11、percutter,or equivalent to cut specimens to 2 by 2 in. size (50.8 by 50.8mm).4.8 OptionalOpen box without spring clips for 2 by 2 in.(50.8 by 50.8 mm) photographic slides, or equivalent, toseparate specimens during conditioning and recovery periods.5. Sampling, Test Specimens and Test Units5.1 The s
12、pecimens shall be 2 by 2 in. (50.8 by 50.8 mm).The test unit shall consist of three specimens.5.2 The central one square inch test area of each specimenshould be free of mortar lines or other embossing lines, ifpossible. If not possible, the largest flat, raised area should becentered on the specime
13、n.1This test method is under the jurisdiction ofASTM Committee F06 on ResilientFloor Coverings and is the direct responsibility of Subcommittee F06.30 on TestMethods - Performance.Current edition approved Oct. 1, 2007. Published October 2007. Originallyapproved in 1987. Last previous edition approve
14、d in 2006 as F 97006.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3For additional information, see Resilie
15、nt Floor Covering Institute (RFCI)document, Static Limit Testing of Resilient Flooring Products, available from RFCI,401 E. Jefferson, Suite 102, Rockville, MD 20850, 1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.3 If the sample
16、is nubble embossed, the specimen shouldbe cut so that a nub is at the center of the specimen where thespecimen will be measured.5.4 A circle slightly larger than the 0.250 in. (6.35 mm)diameter foot of the thickness gauge (4.5) is drawn on the wearlayer at the center of the specimen, using the PMMA
17、template(4.6), to ensure that thickness measurements are made at thesame spot.6. Conditioning6.1 Condition the test unit at least 16 h at 73.4 6 3.6F(23.0 6 2.0C) and 50 6 5 % relative humidity and test in thesame environment (see Specification E 171).7. Procedures7.1 Measure the initial thickness o
18、f each specimen, wearlayer up, at the center of the specimen using the dial microme-ter. Record the value to the nearest 0.001 in. (0.025 mm) as T1.7.2 Place the 2 by 2 in. (50.8 by 50.8 mm) indentor plate ontop of the 2 by 2 in. (50.8 by 50.8 mm) specimen with the 1.125in. (28.58 mm) diameter surfa
19、ce flat against the wear layer ofthe specimen.7.3 Stack the remaining specimens and indentor plates asshown in Fig. 2. Place as many specimen/indentor plate setsunder the indentation machine plunger as will fit.7.4 Square the stack of specimen/indentor plate sets andthen center the stack under the p
20、lunger of the indentationmachine.7.5 Check all clearances to be sure that the plunger andmajor load shaft with weight platform and weights will be freeto move down without restriction as the height of the stack ofspecimens diminishes during test. If necessary, place a metalspacer above or below the
21、plunger, and adjust the position ofthe collar on the plunger that supports a dial indicator (not usedfor static load test) to ensure adequate clearances during test.7.6 Apply the load according to the detail specification (75,125, 175, or 250 lb) by lowering gently, without impact.7.7 Remove the loa
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF9702007STANDARDTESTMETHODFORSTATICLOADLIMIT 荷载 极限 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-537642.html