《ASTM F924-1990(2009) Standard Test Method for Resistance to Puncture of Cushioned Resilient Floor Coverings《减震弹性地板覆盖物的耐刺穿的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F924-1990(2009) Standard Test Method for Resistance to Puncture of Cushioned Resilient Floor Coverings《减震弹性地板覆盖物的耐刺穿的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 924 90 (Reapproved 2009)Standard Test Method forResistance to Puncture of Cushioned Resilient FloorCoverings1This standard is issued under the fixed designation F 924; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision,
2、the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the laboratory procedure fordetermining the resistance of cushioned resilient floo
3、r cover-ings to punctures from dropped pointed objects such as dinnerforks.1.2 This test method employs a 35-g cylindrical dart with aflat, small-diameter tip that is dropped onto a specimen offlooring. The dart represents the weight of a typical fork andthe tip produces a similar puncture to those
4、which result fromdropped forks.1.3 Flooring with thick wear layers may not puncture undereven the most severe drop. Although data can be obtained byincreasing the drop height or the weight of the dart, values ofthis magnitude have no practical application.1.4 The values stated in inch-pound units ar
5、e to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility
6、 of whoever uses this standard to consult andestablish appropriate safety and health practices and deter-mine the applicability and regulatory limitations prior to use.For specific precaution statement see 8.2.2. Referenced Documents2.1 ASTM Standards:2E 171 Specification for Atmospheres for Conditi
7、oning andTesting Flexible Barrier MaterialsF 141 Terminology Relating to Resilient Floor CoveringsF 410 Test Method for Wear Layer Thickness of ResilientFloor Coverings by Optical Measurement3. Terminology3.1 Definitions:3.1.1 For definitions of other terms used in this test method,refer to Terminol
8、ogy F 141.3.2 Definitions of Terms Specific to This Standard:3.2.1 puncturea break in the wear layer of the specimen.An indentation at the point of impact shall be considered apuncture only if the wear layer is broken completely through atsome point.3.2.2 wickingthe presence of ink below the wear la
9、yer ofthe specimen in areas adjacent to a puncture. This can be seennext to the actual cut, and appears either as spots on the patternlayer or as a general discoloration.4. Significance and Use4.1 Much of the cushioned resilient flooring in use today isin household kitchens. Kitchen flooring is freq
10、uently subjectedto the hazard of dropped tableware and cutting knives, that canpuncture the wear layer of cushioned resilient flooring. Foodand soil that become embedded in these punctures often cannot be removed by ordinary maintenance, resulting in unsightlymarks. Moisture, grease, or oils that pe
11、netrate to the cushionlayer can be wicked into the foam and cause permanentdiscoloration. Ultimately, the service life of the material isshortened.5. Apparatus5.1 Dart Drop Assembly (Fig. 1), consisting of a12 in.plywood platform tilted 20 from horizontal, and a verticalslotted tube at least 40 in.
12、(1016 mm) long with an insidediameter of 1.05 6 0.05 in. (26.7 6 2 mm). The mouth of thetube shall be approximately 2 in. (50.8 mm) above the centerof the platform. The tube shall be marked in 1 in. or lessgraduations showing the height above the surface of a mountedspecimen positioned on the platfo
13、rm. At the top of the tubeshall be a flat cap with a14 in. diameter opening in the center.This hole should have smooth, rounded sides.5.2 Dart (Fig. 2), consisting of a 0.970 6 0.003 (246 60.76 mm) outside diameter hollow cylindrical aluminum bodywith a 0.078 6 0.0005 in. (2.0 6 0.013 mm) diameter t
14、ip atone end and a steel wire loop at the other end, weighing a totalof 35 6 0.10 g. A length of size “A” silk thread at least 60 in.long shall be attached to the wire loop.5.3 Microscope or magnifier, 3X or greater.5.4 Alcohol-based ink.1This test method is under the jurisdiction ofASTM Committee F
15、06 on ResilientFloor Coverings and is the direct responsibility of Subcommittee F06.30 on TestMethods - Performance.Current edition approved May 1, 2009. Published July 2009. Originally approvedin 1985. Last previous edition approved in 2004 as F 924 90 (2004).2For referenced ASTM standards, visit t
16、he ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF92419902009STANDARDTESTMETHODFORRESISTANCETOPUNCTUREOFCUSHIONEDRESILIENTFLOORCOVERINGS 减震 弹性 地板

链接地址:http://www.mydoc123.com/p-537567.html