《ASTM F384-2006e1 Standard Specifications and Test Methods for Metallic Angled Orthopedic Fracture Fixation Devices《金属斜角整形外科骨折固定设备的标准规范和试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F384-2006e1 Standard Specifications and Test Methods for Metallic Angled Orthopedic Fracture Fixation Devices《金属斜角整形外科骨折固定设备的标准规范和试验方法》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 384 061Standard Specifications and Test Methods forMetallic Angled Orthopedic Fracture Fixation Devices1This standard is issued under the fixed designation F 384; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the y
2、ear of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEUnits information was editorially corrected in August 2009.1. Scope1.1 These specifications and test methods provide a
3、 com-prehensive reference for angled devices used in the surgicalinternal fixation of the skeletal system. This standard estab-lishes consistent methods to classify and define the geometricand performance characteristics of angled devices. This stan-dard also presents a catalog of standard specifica
4、tions thatspecify material, labeling, and handling requirements, andstandard test methods for measuring performance relatedmechanical characteristics determined to be important to the invivo performance of angled devices.1.2 It is not the intention of this standard to define levels ofperformance of
5、case-specific clinical performance for angleddevices, as insufficient knowledge is available to predict theconsequences of their use in individual patients for specificactivities of daily living. Futhermore, this standard does notdescribe or specify specific designs for angled devices used inthe sur
6、gical internal fixation of the skeletal system.1.3 This standard may not be appropriate for all types ofangled devices. The user is cautioned to consider the appro-priateness of this standard in view of a particular angled deviceand its potential application.NOTE 1This standard is not intended to ad
7、dress intramedullary hipscrew nails or other angled devices without a sideplate.1.4 This standard includes the following test methods usedin determining the following angled device mechanical perfor-mance characteristics:1.4.1 Standard test method for single cycle compressionbend testing of metallic
8、 angled orthopedic fracture fixationdevices (see Annex A1).1.4.2 Standard test method for determining the bendingfatigue properties of metallic angled orthopedic fracture fixa-tion devices (see Annex A2).1.5 The values stated in SI units are to be regarded asstandard. No other units of measurement a
9、re included in thisstandard.NOTE 2There is currently no ISO standard that is either similar toequivalent to this standard.2. Referenced Documents2.1 ASTM Standards:2E4 Practices for Force Verification of Testing MachinesE8 Test Methods for Tension Testing of Metallic MaterialsE 122 Practice for Calc
10、ulating Sample Size to Estimate,With Specified Precision, the Average for a Characteristicof a Lot or ProcessF67 Specification for Unalloyed Titanium, for SurgicalImplant Applications (UNS R50250, UNS R50400, UNSR50550, UNS R50700)F75 Specification for Cobalt-28 Chromium-6 MolybdenumAlloy Castings a
11、nd Casting Alloy for Surgical Implants(UNS R30075)F90 Specification for Wrought Cobalt-20Chromium-15Tungsten-10Nickel Alloy for Surgical Implant Applica-tions (UNS R30605)F 136 Specification for Wrought Titanium-6Aluminum-4Vanadium ELI (Extra Low Interstitial) Alloy for SurgicalImplant Applications
12、(UNS R56401)F 138 Specification for Wrought 18Chromium-14Nickel-2.5Molybdenum Stainless Steel Bar and Wire for SurgicalImplants (UNS S31673)F 139 Specification for Wrought 18Chromium-14Nickel-2.5Molybdenum Stainless Steel Sheet and Strip for Surgi-cal Implants (UNS S31673)F 382 Specification and Tes
13、t Method for Metallic BonePlatesF 543 Specification and Test Methods for Metallic MedicalBone ScrewsF 565 Practice for Care and Handling of Orthopedic Im-plants and InstrumentsF 620 Specification for Alpha Plus Beta Titanium AlloyForgings for Surgical ImplantsF 621 Specification for Stainless Steel
14、Forgings for SurgicalImplants1These specifications and test methods are under the jurisdiction of ASTMCommittee F04 on Medical and Surgical Materials and Devices and are the directresponsibility of Subcommittee F04.21 on Osteosynthesis.Current edition approved Jan. 15, 2006. Published February 2006.
15、 Originallyapproved in 1973. Last previous edition approved in 2000 as F 384 00.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page
16、onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.F 983 Practice for Permanent Marking of Orthopaedic Im-plant ComponentsF 1295 Specification for Wrought Titanium-6Aluminum-7Niobium Alloy for Surgical Implant Applica
17、tions (UNSR56700)F 1314 Specification for Wrought Nitrogen Strengthened 22Chromium 13 Nickel 5 Manganese 2.5 MolybdenumStainless Steel Alloy Bar and Wire for Surgical Implants(UNS S20910)F 1472 Specification for Wrought Titanium-6Aluminum-4Vanadium Alloy for Surgical Implant Applications (UNSR56400)
18、F 1713 Specification for Wrought Titanium-13Niobium-13Zirconium Alloy for Surgical Implant Applications(UNS R58130)2.2 ISO Standards:3ISO 5835 Implants for SurgeryMetal Bone Screws withHexagonal Drive ConnectionSpherical Under Surfaceof Head, Asymmetrical ThreadISO 5836 Implants for SurgeryMetal Bon
19、e PlatesHolesCorresponding to Screws with Asymmetrical Thread andSpherical Under SurfaceISO 9268 Implants for SurgeryMetal Bone Screws withConical Under-Surface of HeadDimensionsISO 9269 Implants for SurgeryMetal Bone PlatesHolesand Slots Corresponding to Screws with Conical Under-SurfaceISO 14602 N
20、on-active Surgical ImplantsImplants forOsteosynthesisParticular Requirements3. Terminology3.1 Definitions: Geometric3.1.1 angle, ndefined at either the barrel/sideplate orblade/sideplate junction (see Fig. 1 and Fig. 2).3.1.2 angled device, na class of orthopedic devices for thefixation of fractures
21、 in the methaphyseal areas of long bonesthat has a component aligned at an angle to the bones longaxis.3.1.3 barrel, nthe portion of an angled device whichcaptures the lag screw (see Fig. 1).3.1.4 barrel length, LBR, n the distance from the free endof the barrel to the interior vertex of the barrel/
22、sideplatejunction (see Fig. 1).3.1.5 blade, nthe portion of an angled device whichtransmits the off axis loading of the anatomical loadingcondition to the sideplate portion of the angled device (see Fig.2).3.1.6 blade length, LBD, nthe distance from the free endof the blade to the interior vertex of
23、 the blade/sideplate junction(see Fig. 2).3.1.7 lag screw, nthat component of a compression hipscrew angled device which is threaded into the metaphyses andtransmits the off axis load to the sideplate through the barrel(see Fig. 1).3.1.8 lag screw length, nthe straight line distance mea-sured betwee
24、n the proximal and distal ends of the lag screw(see Fig. 1).3.1.9 sideplate, nthat portion of the angle device gener-ally aligned with the bones long axis which attaches to thebone via bone screws (see Fig. 1 and Fig. 2).3.1.10 sideplate length, L, nthe distance from the free endof the sideplate to
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF3842006E1STANDARDSPECIFICATIONSANDTESTMETHODSFORMETALLICANGLEDORTHOPEDICFRACTUREFIXATIONDEVICES

链接地址:http://www.mydoc123.com/p-536539.html