ASTM F2055-2017 Standard Test Method for Size and Squareness of Resilient Floor Tile by Dial Gage Method《采用千分表法测定弹性地砖尺寸和垂直度的标准试验方法》.pdf
《ASTM F2055-2017 Standard Test Method for Size and Squareness of Resilient Floor Tile by Dial Gage Method《采用千分表法测定弹性地砖尺寸和垂直度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F2055-2017 Standard Test Method for Size and Squareness of Resilient Floor Tile by Dial Gage Method《采用千分表法测定弹性地砖尺寸和垂直度的标准试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F2055 17Standard Test Method forSize and Squareness of Resilient Floor Tile by Dial GageMethod1This standard is issued under the fixed designation F2055; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last
2、 revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of bothdimensions (length and width) and squareness of resilient floortile. This
3、 test method is intended for use with square tilesranging from a nominal 9 in. (226 mm) to 40 in. (1016 mm) indimension.1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information o
4、nlyand are not considered standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limit
5、ations prior to use.1.4 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization
6、TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2E177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method3. Significance and Use3.1 Both dimension and
7、 squareness of resilient floor tile areimportant considerations, because installed flooring may ex-hibit an objectionable appearance when either or both charac-teristics deviate from established tolerances. This test methodprovides a means of determining actual dimensions and square-ness by using a
8、single apparatus and procedure.4. Apparatus4.1 The apparatus shall consist of four dial gages and tworeference index strips mounted on a flat bedplate in a configu-ration that, by rotation of the sample, allows the measurementof all four sides of resilient tile samples (see Fig. 1). One edgeof the b
9、edplate is elevated to create a test surface which isoffset or tilted 15 6 1 degrees from horizontal. This offsetapplies minimal pressure to the test specimen against thelonger index strip to ensure repeatable measurement. A refer-ence plate representing target tile size and squareness is used tozer
10、o all dial gages (see Fig. 2).4.2 Dial GagesThe four dial gages are mounted in guideslots that are machined into the bedplate to allow for measure-ment of various tile sizes while remaining within 10% of thecorner of the tile edge (for the two corner gages and onesquareness gage) or within the centr
11、al 10% of the tile edge (forthe center gage only). Dial gages may report measurementsusing either electrical or mechanical means, but they shall begraduated to read 0.001 in. (0.02 mm) and have a stem travelgreater than 0.25 in. (6 mm). The contact foot of the dial-gagestem shall be flat 0.500.75 6
12、0.001 in. (12.719.1 mm 6 0.2mm) in diameter and exert a total force of not more than 3.0 60.1 ozf (0.83 6 0.003 N). Dial gages shall be securelypositioned so that when the reference plate is in place, thecontact foot is extended approximately 50% of its full travel.4.3 Index StripsThe apparatus cont
13、ains 2 fixed indexstrips. A horizontal index strip shall be mounted parallel to andjust inside the lower edge of the bedplate. It shall be 1.5 6 0.1in. (38 6 3 mm) greater in length and a minimum of twice thethickness of the largest tile to be tested. A second index stripshall be mounted 90 6 10 s (
14、1.57080 6 0.00005 rad.) to thehorizontal index strip. The lower end of this index strip shall be0.125 6 0.01 in. (3.1 6 0.25 mm) above the right end of thehorizontal index strip and is used to locate one corner of thesample tile.4.4 Reference PlateThe reference plate shall be made tothe target dimen
15、sions of the manufactured tile. The length and1This test method is under the jurisdiction ofASTM Committee F06 on ResilientFloor Coverings and is the direct responsibility of F06.20Test Methods - ProductsConstruction/Materials.Current edition approved May 1, 2017. Published May 2017. Originallyappro
16、ved in 2000. Last previous edition approved in 2010 as F2055-10. DOI:10.1520/F2055-17.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary
17、 page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles fo
18、r theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.1width dimensions shall be within 6 0.001 in. (0.02 mm) of thespecified dimensions of the resilient tile. The reference plateshall contain at lea
19、st two sides which are perpendicular to 906 10 s (1.57080 6 0.00005 rad.) to one another and are usedto set the squareness gage to zero.5. Specimens5.1 The specimens shall consist of 5 full size tiles.6. Conditioning6.1 Condition the test specimens, reference plate, and appa-ratus a minimum of 24 h
20、at 73.4 6 1.8F (23 6 1C) and50 6 10 % relative humidity. Tests shall be conducted in thissame environment. Samples shall be conditioned on a flatsurface such as a table or floor surface to ensure they willcontact the bedplate uniformly during measurement.7. Procedure7.1 Place the appropriate referen
21、ce plate onto the bedplatesurface and slide it firmly against the two index strips. Set eachof the four dial indicators to zero. Remove the reference plate.All dial indicators will now reflect their fully extended mea-surements. In the case of digital dial indicators, the display willindicate a nega
22、tive number. In the case of mechanical dialindicators, the display will move counter-clockwise from zero.NOTE 1Dirt and foreign particles may collect along the upper face ofthe index strip and affect the zero setpoint. Use a small brush to maintainthe cleanliness of the index strip surfaces before a
23、nd after each use.7.2 Measuring Size and SquarenessIdentify one edge ofthe sample tile as “Edge #1” by attaching a label to the face ofthe tile near that edge. Place the tile into the apparatus andcarefully move it into position such that it will depress all fourdial gages and is in firm contact wit
24、h both index strips. Recordthe measurements on all four gages to the nearest 0.001 in.(0.02 mm).7.3 Remove the tile from the bedplate and rotate it 90 in theclockwise direction. Repeat the process described in 7.2 andrecord the four gage readings. Repeat for each of the tworemaining sides.7.4 After
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF20552017STANDARDTESTMETHODFORSIZEANDSQUARENESSOFRESILIENTFLOORTILEBYDIALGAGEMETHOD 采用 千分表 测定 弹性

链接地址:http://www.mydoc123.com/p-536426.html