《ASTM F2025-2006(2018) Standard Practice for Gravimetric Measurement of Polymeric Components for Wear Assessment《磨损评估用聚合体部件重力测量的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM F2025-2006(2018) Standard Practice for Gravimetric Measurement of Polymeric Components for Wear Assessment《磨损评估用聚合体部件重力测量的标准实施规程》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F2025 06 (Reapproved 2018)Standard Practice forGravimetric Measurement of Polymeric Components forWear Assessment1This standard is issued under the fixed designation F2025; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revisio
2、n, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice describes a laboratory method using aweight-loss (that is, mass-loss; see X1.4) technique
3、 for evalu-ating the wear properties of polymeric materials or deviceswhich are being considered for use as bearing surfaces ofhuman joint replacement prostheses. The test specimens areevaluated in a device intended to simulate the tribologicalconditions encountered in the human joint; for example,
4、use ofa fluid such as bovine serum, or equivalent pseudosynovialfluid shown to simulate similar wear mechanisms and debrisgeneration found in vivo.1.2 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision o
5、n Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D792 Test Methods for Density and Specific Gravity (Rela-tive Density) of Plastics by D
6、isplacementD1505 Test Method for Density of Plastics by the Density-Gradient TechniqueF732 Test Method for Wear Testing of Polymeric MaterialsUsed in Total Joint ProsthesesF1714 Guide for Gravimetric WearAssessment of ProstheticHip Designs in Simulator Devices2.2 Other Standards:3ISO 142422 Implants
7、 for SurgeryWear ofTotal Hip-JointProsthesesPart 2: Methods of MeasurementISO 142432 Implants for SurgeryWear of Total Knee-Joint ProsthesesPart 2: Methods of Measurement3. Significance and Use3.1 This practice uses a weight-loss method of wear deter-mination for the polymeric components or material
8、s used inhuman joint prostheses, using serum or demonstrated equiva-lent fluid for lubrication, and running under a load profilerepresentative of the appropriate human joint application(1,2).4The basis for this weight-loss method for wear mea-surement was originally developed (3) for pin-on-disk wea
9、rstudies (Practice F732) and has been extended to total hipreplacements (4, 5, ISO 142422, and Guide F1714), and tofemoro-tibial knee prostheses (6 and ISO 142432), and tofemoro-patellar knee prostheses (6,7).3.2 While wear results in a change in the physical dimen-sions of the specimen, it is disti
10、nct from dimensional changesdue to creep or plastic deformation, in that wear results in theremoval of material in the form of polymeric debris particles,causing a loss in weight of the specimen.3.3 This practice for measuring wear of the polymericcomponent is suitable for various simulator devices.
11、 Thesetechniques can be used with metal, ceramic, carbon, polymeric,and composite counter faces bearing against a polymericmaterial (for example, polyethylene, polyacetal, and so forth).Thus, this weight-loss method has universal application forwear studies of human joint replacements which featurep
12、olymeric bearings. This weight-loss method has not beenvalidated for non-polymeric material bearing systems, such asmetal-metal, carbon-carbon, or ceramic-ceramic. Progressivewear of such rigid bearing combinations has generally beenmonitored using linear, variable-displacement transducers, orby oth
13、er profilometric techniques.4. Components and Materials4.1 Hip Prosthesis ComponentsThe hip joint prosthesiscomprises a ball-and-socket configuration in which materialssuch as polymers, composites, metal alloys, ceramics, andcarbon have been used in various combinations and designs.1This practice is
14、 under the jurisdiction ofASTM Committee F04 on Medical andSurgical Materials and Devices and is the direct responsibility of SubcommitteeF04.22 on Arthroplasty.Current edition approved April 1, 2018. Published May 2018. Originallyapproved in 2000. Last previous edition approved in 2012 as F2025 06
15、(2012).DOI: 10.1520/F2025-06R18.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American Nati
16、onal Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036.4The boldface numbers in parentheses refer to the list of references at the end ofthis standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis internat
17、ional standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Commit
18、tee.14.1.1 Component ConfigurationsThe diameter of theprosthetic ball may vary from 22 to 54 mm or larger. Thedesign may include ball-socket, trunnion, bipolar, or otherconfigurations. If applicable, the normal metal backing for thepolymeric component shall be used provided disassembly andreassembly
19、 of these components for the measurement does nothave an unrepresentative effect on the weight measurements orwear behavior. Otherwise, a modified backing may be used,again provided this has no unrepresentative effect on theweight measurements or wear behavior (see X1.5).4.2 Knee Prosthesis Componen
20、tsThe knee joint comprisesfemoral, tibial, and patellar configurations in which materialssuch as metal alloys, ceramics, polymers, and carbon materialshave been used in various combinations in different designs.4.2.1 Component ConfigurationsThe polymeric compo-nents may be backed by either metal, ce
21、ramic, or compositereinforcements. If applicable, the normal metal backing shallbe used provided disassembly and reassembly of these com-ponents for the measurement does not have an unrepresentativeeffect on the weight measurements or wear behavior.Otherwise, a modified backing may be used, again pr
22、ovidedthis has no unrepresentative effect on the weight measurementsor wear behavior (see X1.5).4.3 Other prosthesis components and test coupons may beused to represent other human joint replacement applications.5. Specimen Preparation5.1 Polymers and CompositesMaterial Condition:5.1.1 A fabrication
23、 history shall be obtained for each poly-meric or composite component, including information such asgrade, batch number and processing variables, method offorming (extruding, molding, and so forth), temperature, pres-sure and forming time used, and any post-forming treatments,including the steriliza
24、tion method and parameters.5.1.2 Pretest characterization may include measurement ofbulk material properties such as molecular-weight range anddistribution, percent crystallinity, or other. Density is a particu-larly important property because of the conversion of weightmeasurements to volumetric we
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF202520062018STANDARDPRACTICEFORGRAVIMETRICMEASUREMENTOFPOLYMERICCOMPONENTSFORWEARASSESSMENT 磨损 评估

链接地址:http://www.mydoc123.com/p-536329.html