ASTM F2006-2010 Standard Safety Specification for Window Fall Prevention Devices for Non-Emergency Escape (Egress) and Rescue (Ingress) Windows《非紧急出口和营救(进入)窗口用窗防跌落装置的标准安全规范》.pdf
《ASTM F2006-2010 Standard Safety Specification for Window Fall Prevention Devices for Non-Emergency Escape (Egress) and Rescue (Ingress) Windows《非紧急出口和营救(进入)窗口用窗防跌落装置的标准安全规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM F2006-2010 Standard Safety Specification for Window Fall Prevention Devices for Non-Emergency Escape (Egress) and Rescue (Ingress) Windows《非紧急出口和营救(进入)窗口用窗防跌落装置的标准安全规范》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F2006 10Standard Safety Specification forWindow Fall Prevention Devices for Non-Emergency Escape(Egress) and Rescue (Ingress) Windows1,2This standard is issued under the fixed designation F2006; the number immediately following the designation indicates the year oforiginal adoption or,
2、in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONThe consumer safety specification addresses window fall prevention devices that p
3、rotect againstpotential falls by children age five and under through open windows not designated for emergencyescape or rescue in installations more than 75 ft (23 m) above ground level in multiple family dwellingbuildings since windows at these heights are beyond the reach of rescue ladders current
4、ly in use.Window fall prevention devices currently available include window opening control devices, windowfall prevention screens, and some types of window guards. These devices use different strategies toprevent children from falling through open windows. Window opening control devices restrict th
5、e sizeof the open area of the window so that it is too small for a young child to fall through. They do thisby allowing the window opening to be set at a predetermined position. Window fall prevention screensand fall prevention window guards provide a barrier to prevent a child from falling through
6、an openwindow. This specification does not apply to devices applied to windows installed in one and twofamily dwellings.A special study3by the U.S. Consumer Product Safety Commission indicates that young childrenare at high risk of death and serious injury from window falls. Children age five and yo
7、unger accountfor a higher percentage of window fall fatalities and injuries.4Window fall prevention devices usually differ in purpose and application from security/burglar bars.The general purpose of a window fall prevention device is to prevent a child age five or younger fromfalling through an ope
8、n window. The general purpose of a security bar is to prevent unlawful entrythrough a window. Generally window fall prevention devices and security bars are two separatedevices. However, a security bar could be used as a fall prevention device if it meets the requirementsof this specification.The CP
9、SC has advised caregivers to open windows less than 4 in. when children are present as onemeans to prevent child falls through open windows. Window opening control devices provide a meansthat the window, when opened in an initial operation, will satisfy the CPSC recommendation to openless than 4 in.
10、5The 4-in. dimension is drawn from related building codes and standards for openingsin guardrail assemblies,6and is universally accepted as the appropriate dimension to prevent a childfrom passing through balcony or guard railing systems.An additional operation is required to open thewindow further.
11、 The additional operation must be performed without the use of keys, tools or specialknowledge. Security from forced entry is not within the scope of this standard and is not the intendedfunction of any of the devices referred to herein.1. Scope1.1 This safety specification establishes requirements
12、fordevices intended to address the risk of injury and death1This safety specification is under the jurisdiction of ASTM Committee F15 andis the direct responsibility of Subcommittee F15.38 on Window Fall Prevention.Current edition approved March 15, 2010. Published April 2010. Originallyapproved in
13、2000. Last previous edition approved in 2008 as F2006 08. DOI:10.1520/F2006-10.2This standard replaces former Provisonal Safety Specification PS 112.3U.S. Consumer Product Safety Commission, special window falls studyconducted in 1991.4U.S. Consumer Product Safety Commission, special window falls st
14、udyconducted in 1991 and “Window Safety: Data and Patterns Related to Entrapmentsand Accidental Falls from Windows,” prepared by Anderson Corporation.Supporting data have been filed atASTM International Headquarters and may beobtained by requesting Research Report RR:F15-1002.5Consumer Product Safet
15、y Commission, “Preventing Window Falls,” Document#5124.6See NFPA 101, 2006 Edition Section 7.2.2.4.5.3. Also see Section R312.2Guard opening limitations in the 2006 International Residential Code (IRC).1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-295
16、9, United States.associated with accidental falls through open windows bychildren five years old and younger.NOTE 1This specification is not intended to meet the unique require-ments of Americans With Disabilities Act (ADA).1.2 This safety specification applies only to window fallprevention devices,
17、 including window opening control devices,window fall prevention screens, and fall prevention windowguards that are to be used on windows that are not intended forescape (egress) and rescue (ingress).NOTE 2Specification F2090 addresses window fall prevention de-vices (releasable) for windows intende
18、d for emergency escape and rescueand any other window not covered by this specification.1.3 This safety specification applies only to devices in-tended to be applied to windows installed at heights of morethan 75 ft7(23 m) above ground level in multiple familydwelling buildings. This safety specific
19、ation is not intended toapply to windows below 75 ft (23 m) because all windowsbelow 75 ft (23 m) that are operable could be used as a possiblesecondary means of escape.81.4 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversio
20、ns to SI units that are provided for information onlyand are not considered standard.1.5 This standard does not purport to address all safetyconcerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety andhealth practices and to dete
21、rmine the applicability of regula-tory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:9F1487 Consumer Safety Performance Specification forPlayground Equipment for Public UseF2090 Specification for Window Fall Prevention DevicesWith Emergency Escape (Egress) Release Mechanisms2.2
22、Code of Federal Regulations:1016 CFR 1201 Safety Standard for Architectural GlazingMaterials16 CFR 1500.53 Test Methods for Simulating Use andAbuse of Toys and Other Articles Intended for Use byChildren Over 36 But Not Over 96 Months of Age, (f)(3)Testing Procedure16 CFR 1508.6 (b) Requirements for
23、Full-Size Baby Cribs2.3 ANSI Standard:11ANSI Z97.1-1984 Safety Glazing Materials Used in Build-ings Safety Performance Specifications and Methods ofTest (Tempered Glass Impact Test)ANSI Z535.4 American National Standard for ProductSafety Signs and LabelsANSI Z535.6 Product Safety Instructions in Pro
24、duct Manu-als, Instructions and Other Collateral MaterialsANSI/BHMA A156.9 American National Standard forCabinet HardwareANSI/SMA 1201-2002 Specification for Insect Screens forWindows, Sliding Doors and Swinging Doors2.4 AAMA Standards:12AAMA/SDMA/CSA 101/IS.2/A440-08 North AmericanFenestration Stan
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF20062010STANDARDSAFETYSPECIFICATIONFORWINDOWFALLPREVENTIONDEVICESFORNONEMERGENCYESCAPEEGRESSANDRESCUEINGRESSWINDOWS

链接地址:http://www.mydoc123.com/p-536271.html