《ASTM F1983-2014 Standard Practice for Assessment of Selected Tissue Effects of Absorbable Biomaterials for Implant Applications《评估植入物用可吸收性生物材料的选择组织显影的标准实践规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM F1983-2014 Standard Practice for Assessment of Selected Tissue Effects of Absorbable Biomaterials for Implant Applications《评估植入物用可吸收性生物材料的选择组织显影的标准实践规程》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F1983 14Standard Practice forAssessment of Selected Tissue Effects of AbsorbableBiomaterials for Implant Applications1This standard is issued under the fixed designation F1983; the number immediately following the designation indicates the year oforiginal adoption or, in the case of rev
2、ision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice provides experimental protocols for bio-logical assays of tissue reactions to absorba
3、ble biomaterials forimplant applications. This practice applies only to absorbablematerials with projected clinical applications in which thematerials will reside in bone or soft tissue longer than 30 daysand less than three years. Other standards with designatedimplantation times are available to a
4、ddress shorter time peri-ods. Careful consideration should be given to the appropriate-ness of this practice for slowly degrading materials that willremain for longer than three years. It is anticipated that thetissue response to degrading biomaterials will be different fromthe response to nonabsorb
5、able materials. In many cases, achronic inflammatory response may be observed during thedegradation phase, but the local histology should return tonormal after absorption; therefore, the minimal tissue responseusually equated with “biocompatibility” may require longimplantations.1.2 The time period
6、for implant absorption will vary de-pending on chemical composition implant size, implantlocation, and test subject species; therefore, the implantationtimes for examination of tissue response will be linked to therate of absorption. No single implantation time is indicated inthis practice.1.3 These
7、 protocols assess the effects of the material on theanimal tissue in which it is implanted. The experimentalprotocols do not fully assess systemic toxicity, carcinogenicity,teratogenicity, or mutagenicity of the material. Other standardsare available to address these issues.1.4 To maximize use of th
8、e animals in the study protocol, alltoxicological findings should be recorded. There are someaspects of systemic toxicity, including effects of degradationproducts on the target organs, that can be addressed with thispractice, and these effects should be documented fully.1.5 This standard does not p
9、urport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2
10、F561 Practice for Retrieval and Analysis of MedicalDevices, and Associated Tissues and FluidsF750 Practice for Evaluating Material Extracts by SystemicInjection in the MouseF763 Practice for Short-Term Screening of Implant Materi-alsF981 Practice for Assessment of Compatibility of Biomate-rials for
11、Surgical Implants with Respect to Effect ofMaterials on Muscle and BoneF1408 Practice for Subcutaneous Screening Test for ImplantMaterialsF1903 Practice for Testing For Biological Responses toParticles In VitroF1904 Practice for Testing the Biological Responses toParticles in vivoF1905 Practice For
12、Selecting Tests for Determining thePropensity of Materials to Cause Immunotoxicity (With-drawn 2011)3F1906 Practice for Evaluation of Immune Responses InBiocompatibility Testing Using ELISATests, LymphocyteProliferation, and Cell Migration (Withdrawn 2011)33. Summary of Practice3.1 Under strict asep
13、tic conditions, specimens of the sterilefinal implant form candidate material are implanted into themost relevant anatomical tissue site in small laboratoryanimals, preferably mice, rats, hamsters, or rabbits.1This practice is under the jurisdiction of ASTM CommitteeF04 on Medical andSurgical Materi
14、als and Devices and is the direct responsibility of SubcommitteeF04.16 on Biocompatibility Test Methods.Current edition approved Nov. 1, 2014. Published January 2015. Originallyapproved in 1999. Last previous edition approved in 2008 as F1983 99 (2008).DOI: 10.1520/F1983-14.2For referenced ASTM stan
15、dards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.Co
16、pyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.2 The use of larger animals, such as the dog, goat, orsheep may be justified based upon special considerations of theparticular study. Choice of species also should consider theavailabil
17、ity of historical data on biological responses of theseanimals to similar devices to aid in analysis and comparison ofthe data obtained.3.3 All animal studies shall be done in a facility approvedby a nationally recognized organization and in accordance withall appropriate regulations.4. Significance
18、 and Use4.1 This practice is a guideline for a screening test for theevaluation of the local tissue response to materials that may beselected for implantation into the human body and which areexpected to undergo absorption within three years.4.2 This practice is similar to that for studies on candid
19、atematerials that are not absorbable, such as those specified inPractices F763, F981, and F1408; however, analysis of the hostresponse must take into account the effect of degradation anddegradation products on the inflammatory response at the localtissue site and on subsequent healing of the implan
20、tation site.4.3 The material to be tested should be in the final finishedform as for intended use, including sterilization. Material/bodyratios should be relevant to that of intended device use.Material surface area or mass to body mass ratios of 1X, 10X,and 50X if applicable, are recommended.4.4 Ma
21、terials that are designed for use in devices with insitu polymerization shall be introduced in a manner such that insitu polymerization occurs. Testing of individual precursorcomponents is not recommended.5. Test Animals and Sites5.1 Choice of test animal shall take into consideration thenormal life
22、 span of the animal and the length of the implanta-tion study. Small laboratory animals are preferred. The strain,sex, age, and origin of the animals used should be noted. Iflarger animals are used, justification for their use should beprovided. The source of the animals, species/strain, weight, age
23、(where known or approximate if not known), general health,and boarding conditions should be recorded. Animal use andcare regulations shall be followed.5.2 The number of implant sites shall depend on the size ofthe implant and the animal. The distance between implantsshall be sufficient so that separ
24、ate tissue blocks are preparedeasily for each implant and that the biological reactions do notoverlap or interfere with each other. Implants may be placedbilaterally in soft tissue, including muscle. Bilateral implanta-tion into bone should be considered carefully and justificationgiven. In general,
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF19832014STANDARDPRACTICEFORASSESSMENTOFSELECTEDTISSUEEFFECTSOFABSORBABLEBIOMATERIALSFORIMPLANTAPPLICATIONS

链接地址:http://www.mydoc123.com/p-536221.html