ASTM F1796-2009(2014) Standard Specification for High Voltage DetectorsPart 1 Capacitive Type to be Used for Voltages Exceeding 600 Volts AC《高压检测器的标准规格 第1部分 超过600 V交流电压用电容式》.pdf
《ASTM F1796-2009(2014) Standard Specification for High Voltage DetectorsPart 1 Capacitive Type to be Used for Voltages Exceeding 600 Volts AC《高压检测器的标准规格 第1部分 超过600 V交流电压用电容式》.pdf》由会员分享,可在线阅读,更多相关《ASTM F1796-2009(2014) Standard Specification for High Voltage DetectorsPart 1 Capacitive Type to be Used for Voltages Exceeding 600 Volts AC《高压检测器的标准规格 第1部分 超过600 V交流电压用电容式》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F1796 09 (Reapproved 2014)Standard Specification forHigh Voltage DetectorsPart 1 Capacitive Type to be Usedfor Voltages Exceeding 600 Volts AC1This standard is issued under the fixed designation F1796; the number immediately following the designation indicates the year oforiginal adopti
2、on or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers portable, live-line tool-supported, direct-conta
3、ct type capacitive voltage detectors tobe used on electrical systems both indoors and outdoors for acvoltages from 600 V to 800 kV with frequency of 60 Hz. Thefunction of the voltage detector is limited to the detection of thepresence or absence of nominal operating voltage.1.1.1 Two types of voltag
4、e detectors are provided and aredesignated as Type I, audible/visual and Type II, numeric, withor without audible.1.1.2 Two styles of voltage detectors, differing in wetconditions characteristics, are provided and are designated asStyle A, indoor use and Style B indoor/outdoor use.1.2 The use and ma
5、intenance of these high voltage detectorsand any necessary insulated tool handles are beyond the scopeof this specification.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appr
6、o-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.NOTE 1Except where specified, all voltage defined in this specifica-tion refer to phase-to-phase voltage in a three-phase system. Voltagedetectors covered by this specification may be used in
7、 other thanthree-phase systems, but the applicable phase-to-phase or phase-to-ground(earth) voltages shall be used to determine the operating voltage.2. Referenced Documents2.1 ASTM Standards:2F819 Terminology Relating to Electrical Protective Equip-ment for Workers2.2 ANSI Standard:3ANSI C84.1 Volt
8、age Ratings for Electric Power Systemsand Equipment3. Terminology3.1 Definitions:3.1.1 capacitive voltage detectora device that relies oncurrent passing through stray capacitance to ground.3.1.2 clear indicationa specific condition that detects andindicates the voltage state at the contact electrode
9、.3.1.3 clear perceptionthe ability by the user to determinethat the voltage detector is in its operating position.3.1.4 contact electrodethe bare conductive part of theconductive element that establishes the electrical connection tothe component to be tested.3.1.5 indicatorpart of the voltage detect
10、or that indicatesthe presence or absence of the nominal operating voltage or themeasured voltage at the contact electrode.3.1.6 indoor stylea detector designed for use in dryconditions, normally indoors.3.1.7 interference fieldelectrical field affecting the indica-tion.3.1.8 interference voltagevolt
11、ages other than the signalvoltage capable of making the device operate.3.1.9 limit markingdistinctive location or mark to indicateto the user the physical limit to which the detector may beinserted between live components or may touch them.3.1.10 nominal operating voltagea nominal value consis-tent
12、with the latest revision of ANSI C84.1.3.1.11 outdoor stylea detector designed for use eitherindoors or outdoors.3.1.12 response timetime delay between sudden change ofthe voltage state on the contact electrode and the associatedclear indication.3.1.13 testing elementbuilt in or external device, bym
13、eans of which the functioning of the voltage detector can bechecked.1This specification is under the jurisdiction of ASTM Committee F18 onElectrical Protective Equipment for Workers and is the direct responsibility ofSubcommittee F18.35 on Tools or numeric indication,corresponding to specific condit
14、ions as defined in correspond-ing test (see clear indication and clear perception).3.1.15 voltage detectora device for indicating the pres-ence or absence of nominal design or operating voltage or themeasured voltage.3.1.16 voltage, nominal designa nominal value consistentwith the latest revision of
15、 ANSI C84.1, assigned to the circuitor system for the purpose of conveniently designating itsvoltage class.3.1.17 voltage rangevalue of voltage generally agreedupon by manufacturer and customer, to which certain operatingspecifications are referred.3.2 Tests:3.2.1 acceptance test a test made at the
16、option of thepurchaser.3.2.2 design test a type test made on a specimen treated asrepresentative of an industrial product. These tests will notgenerally be repeated in quantity production unless a change inthe design is implemented.3.2.3 performance test a test performed to indicate normaloperation
17、of the instrument.3.2.4 routine test a type test made regularly on productionmaterial.4. Significance and Use4.1 This specification establishes requirements for the de-sign and testing of high voltage detectors, used in the electricalpower industry, to determine the presence or absence ofnominal ope
18、rating voltage or the measured voltage.5. Type of Detector5.1 Capacitive5.1.1 Direct ContactOperates without the need for aground lead, but requires physical contact with the componentto be tested; with an audible/visual indicator.5.1.2 Type II Direct Contact Operates without the needfor a ground le
19、ad, but requires physical contact with thecomponent to be tested; with a numeric value indicator, with orwithout audible.6. Ordering Information6.1 Orders for high voltage detectors under this specifica-tion shall include this ASTM designation and the followinginformation:6.1.1 Type,6.1.2 Style,6.1.
20、3 Voltage range,6.1.4 Catalog number/s.7. Marking7.1 Labeling:7.1.1 Instructions for indoor and outdoor testing use andmaintenance of the voltage detectors shall be included witheach unit. Whenever practicable, instructions for use andtesting shall be printed on a permanent-type label and attachedto
21、 the unit.7.1.2 Voltage range, manufacturer and a general statementregarding any use precautions or limitations shall be perma-nently marked on each unit.8. Specifications8.1 The manufacturer shall clearly specify the limits ofperformance of each voltage detector within the instructions asfollows:8.
22、1.1 Operating voltage range or ranges,8.1.2 Operating temperature range,8.1.3 Operating humidity range,8.1.4 Storage temperature range,8.1.5 Storage humidity range, and8.1.6 Any limitations in use.9. Workmanship, Finish, and Appearance9.1 Workmanship and finish shall be of such quality as toensure s
23、afe operation of the unit. Appearance shall be theprerogative of the manufacturer.10. Testing10.1 GeneralTests shall be performed on a detector thathas been completely assembled. Tests shall be carried outunder the following ambient test conditions:10.1.1 Ambient temperature 59 to 95F (15 to 35C).10
24、.1.2 Relative humidity 45 to 75 %.10.2 MethodsUnless otherwise specified, tests shall becarried out using a 60 Hz ac power source. Tests shall beperformed in dry conditions.10.2.1 The maximum test voltage level shall be reachedwithin 10 to 20 s.10.2.2 An acceptable tolerance of 63 % is allowed for a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF179620092014STANDARDSPECIFICATIONFORHIGHVOLTAGEDETECTORSPART1CAPACITIVETYPETOBEUSEDFORVOLTAGESEXCEEDING600VOLTSAC

链接地址:http://www.mydoc123.com/p-535683.html