《ASTM F1796-1997(2002) Standard Specification for High Voltage Detectors&8212 Part 1 Capacitive Type to be Used for Voltages Exceeding 600 Volts AC《高压探测器用标准规范 第1部分 超过600伏交流电压用电容式探测器.pdf》由会员分享,可在线阅读,更多相关《ASTM F1796-1997(2002) Standard Specification for High Voltage Detectors&8212 Part 1 Capacitive Type to be Used for Voltages Exceeding 600 Volts AC《高压探测器用标准规范 第1部分 超过600伏交流电压用电容式探测器.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 1796 97 (Reapproved 2002)Standard Specification forHigh Voltage DetectorsPart 1 Capacitive Type to be Usedfor Voltages Exceeding 600 Volts AC1This standard is issued under the fixed designation F 1796; the number immediately following the designation indicates the year oforiginal adop
2、tion or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers portable, live-line tool-supported, direct-co
3、ntact type capacitive voltage detectors tobe used on electrical systems both indoors and outdoors for acvoltages from 600 V to 800 kV with frequency of 60 Hz. Thefunction of the voltage detector is limited to the detection of thepresence or absence of nominal operating voltage.1.1.1 This specificati
4、on is not applicable to other types ofvoltage detectors.1.2 The use and maintenance of these high voltage detectorsand any necessary insulated tool handles are beyond the scopeof this specification.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its u
5、se. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.NOTE 1Except where specified, all voltage defined in this specifica-tion refer to phase-to-phase voltage in a three-p
6、hase system. Voltagedetectors covered by this specification may be used in other thanthree-phase systems, but the applicable phase-to-phase or phase-to-ground(earth) voltages shall be used to determine the operating voltage.2. Referenced Documents2.1 ASTM Standards:F 819 Definitions of Terms Relatin
7、g to Electrical ProtectiveEquipment for Workers22.2 Other Standard:3Fed/OSHA (1910, 137, 269, Subpart S)2.3 ANSI Standard:4ANSI C84.1 Voltage Ratings for Electric Power Systemsand Equipment2.4 IEEE Standards:5IEEE 516 Guide for Maintenance Methods on EnergizedPower LinesIEEE 4 High Voltage Testing T
8、echniquesf2.5 IEC Standard:6IEC 1243-1 First Addition 1993-113. Terminology3.1 Definitions:3.1.1 capacitive voltage detectora device that relies oncurrent passing through stray capacitance to ground.3.1.2 clear indicationa specific condition that detects andindicates the voltage state at the contact
9、 electrode.3.1.3 clear perceptionthe ability by the user to determinethat the voltage detector is in its operating position.3.1.4 contact electrodethe bare conductive part of theconductive element that establishes the electrical connection tothe component to be tested.3.1.5 indicatorpart of the volt
10、age detector that indicatesthe presence or absence of the operating voltage at the contactelectrode.3.1.6 indoor typea detector designed for use in dryconditions, normally indoors.3.1.7 interference fieldelectrical field affecting the indica-tion.3.1.8 interference voltagevoltages other than the sig
11、nalvoltage capable of making the device operate.3.1.9 limit markingdistinctive location or mark to indicateto the user the physical limit to which the detector may beinserted between live components or may touch them.3.1.10 nominal operating voltagea nominal value consis-tent with the latest revisio
12、n of ANSI C84.1.3.1.11 non-contact proximity detectora device that relieson current passing through stray capacitance to ground withoutmaking direct contact with the component to be tested.3.1.12 outdoor typea detector designed for use eitherindoors or outdoors.3.1.13 response timetime delay between
13、 sudden change1This specification is under the jurisdiction of ASTM Committee F18 onElectrical Protective Equipment for Workers and is the direct responsibility ofSubcommittee F18.35 on Tools and Equipment.Current edition approved April 10, 1997. Published December 1997.2Annual Book of ASTM Standard
14、s, Vol 10.03.3Available from the Superintendent of Documents, U.S. Government PrintingOffice, P.O. Box 37082, Washington, DC 20013-7082.4Available from American National Standards Institute, 11 West 42nd St., 13thFloor, New York, NY 10036.5Available from the Institute of Electrical and Electronics E
15、ngineers, Inc., 345East 47th St., New York, NY 10017.6Available from the International Electrotechnical Commission, (IEC) SalesDepartment, Case Postale 131, 3 rue de Varemb, CH-1211, Geneva 20,Switzerland/Suisse. Also available in the United States from the Sales Department,American National Standar
16、ds Institute, 11 West 42nd St., 13th Floor, New York, NY10036.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.of the voltage state on the contact electrode and the associatedclear indication.3.1.14 testing elementbuilt in or external
17、 device, bymeans of which the functioning of the voltage detector can bechecked.3.1.15 threshold voltageminimum voltage between theline component and earth (ground) required to give a clearaudible or visual indication, or both, corresponding to specificconditions as defined in corresponding test (se
18、e clear indica-tion and clear perception).3.1.16 voltage detectora device for indicating the pres-ence or absence of nominal design or operating voltage.3.1.17 voltage, nominal designa nominal value consistentwith the latest revision of ANSI C84.1, assigned to the circuitor system for the purpose of
19、 conveniently designating itsvoltage class.3.1.18 voltage rangevalue of voltage generally agreedupon by manufacturer and customer, to which certain operatingspecifications are referred.3.2 Tests:3.2.1 acceptance testa test made at the option of thepurchaser.3.2.2 design testa type test made on a spe
20、cimen treated asrepresentative of an industrial product. These tests will notgenerally be repeated in quantity production unless a change inthe design is implemented.3.2.3 performance testa test performed to indicate normaloperation of the instrument.3.2.4 routine testa type test made regularly on p
21、roductionmaterial.4. Significance and Use4.1 This specification establishes requirements for the de-sign and testing of high voltage detectors, used in the electricalpower industry, to determine the presence or absence ofnominal operating voltage.5. Type of Detector5.1 Capacitive5.1.1 Direct Contact
22、Operates without the need for aground lead, but requires physical contact with the componentto be tested.6. Ordering Information6.1 Orders for high voltage detectors under this specifica-tion should include the following information:6.1.1 Type,6.1.2 Voltage range,6.1.3 Tested to meet ASTM F 1796, an
23、d6.1.4 Catalog numbers.7. Marking7.1 Labeling:7.1.1 Instructions for indoor and outdoor testing use andmaintenance of the voltage detectors shall be included witheach unit. Whenever practicable, instructions for use andtesting shall be printed on a permanent-type label and attachedto the unit.7.1.2
24、Voltage range, manufacturer and a general statementregarding any use precautions or limitations shall be perma-nently marked on each unit.8. Specifications8.1 The manufacturer shall clearly specify the limits ofperformance of each voltage detector within the instructions asfollows:8.1.1 Operating vo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF179619972002STANDARDSPECIFICATIONFORHIGHVOLTAGEDETECTORS8212PART1CAPACITIVETYPETOBEUSEDFORVOLTAGESEXCEEDING600VOLTSAC

链接地址:http://www.mydoc123.com/p-535681.html