ASTM F1758-2005(2012) Standard Test Methods for Detention Hinges Used on Detention-Grade Swinging Doors《安全等级双开式弹簧门用安全铰链的标准试验方法》.pdf
《ASTM F1758-2005(2012) Standard Test Methods for Detention Hinges Used on Detention-Grade Swinging Doors《安全等级双开式弹簧门用安全铰链的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F1758-2005(2012) Standard Test Methods for Detention Hinges Used on Detention-Grade Swinging Doors《安全等级双开式弹簧门用安全铰链的标准试验方法》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F1758 05 (Reapproved 2012)Standard Test Methods forDetention Hinges Used on Detention-Grade SwingingDoors1This standard is issued under the fixed designation F1758; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the y
2、ear of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods cover the apparatus, procedures, andacceptance conditions for evaluating the normal operatin
3、gperformance characteristics and the performance characteris-tics under assault conditions of hinges used in swinging doorassemblies in detention and correctional institutions. Thesetypes of hinges are described in detail in 3.1.6, 3.1.9, and3.1.22. Thus, these test methods only give an indication o
4、f theperformance characteristics of hinges in actual service. Suchvariables as installation and maintenance conditions whichhave a potential impact on performance characteristics are notconsidered.1.2 It is the intent of these test methods to help ensure thatdetention hinges (reference to hinges is
5、inclusive of a continu-ous hinge) perform at or above minimum acceptable levels toconfine inmates, to delay and frustrate escape attempts, and toresist vandalism and assault conditions. It is recognized that inorder to meet the intent of these test methods, door, frame andlock assemblies must be com
6、patible with the level of perfor-mance required by Test Methods F1450 and F1577.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and det
7、ermine the applica-bility of regulatory limitations prior to use.1.4 The values stated in inch-pound units are to be regardedas the standard. The values in parentheses are for informationonly.1.5 Consult NFPA 80 for Fire Doors any change ofcomponents or assembly methods or processes shall be certi-f
8、ied in writing by the testing and certification laboratory. Thelaboratory shall have the sole authority to decide the extent andscope of retesting required.5.4 Test reports shall include complete details and photo-graphs of the test specimen, the testing apparatus and installa-tion instructions incl
9、uding templates.6. Cycle Testing6.1 Sample PreparationConduct the test methods usingthree detention hinges per door. When testing a continuous-type hinge on a full door height sample, one hinge shall beused.6.1.1 Prior to being mounted on the test doors, check fullyassembled hinges for vertical and
10、lateral clearances. Ensure allend play has been removed in each sample prior to thismeasurement. The clearance values shall not exceed thosespecified in Table 1.6.1.2 Install the hinges, fully assembled, to the door permanufacturers standard installation instructions.6.1.2.1 At a minimum for alignme
11、nt, lay a straightedgealong the edge of the door at such position as corresponds tothe back edge of a recommended mortise. In applying thehinges, firmly abut the back edge of the door leaf against thisstraightedge as the screws are applied and tightened. Applyjamb mounting blocks to the hinge jamb l
12、eaves using thescrews supplied. Tighten screws in accordance with the fas-tener manufacturers recommended tightening torque. Positionthe door with its three hinges and jamb mounting blocksagainst the vertical jamb, and apply the hexagon-head capscrews and lock washers finger tight. Align edges of ja
13、mbleaves with the straightedge and tighten cap screws securely.Do not mortise door and jamb leaves of the hinges.6.2 ApparatusDetails of a typical test apparatus are inAppendix X1. Alternate designs of the test apparatus areacceptable only if the proper engineering evaluation is con-ducted.6.2.1 The
14、 test door apparatus shall be designed in such amanner that the lateral loads or moment induced on the hingesunder this test will be equivalent to the minimum valueassociated witha3by7ftdoor (914.4 by 2133.6 mm). Hingespacing shall be in accordance with ANSI/NAAMM/HMMA863. Refer to Appendix X2 for l
15、ateral load calculations. Anoversized door shall be permitted to be tested separately orcertified in accordance with 9.5.6.3 ProcedureAdd the proper amount of additionalweights to the apparatus for the grade level being tested inTable 1.6.3.1 Prior to the start of the cycle test perform the follow-i
16、ng:6.3.1.1 Determine a measurement location for vertical andlateral wear on all hinges. The location shall be the same eachtime a measurement is taken. The angular position of the doorshall also be the same within 2 in. (50.8 mm) for eachmeasurement. Record vertical and lateral measurements for allh
17、inges. Vertical measurement is between the adjacent jamb anddoor knuckles. Lateral measurement is between the inner edgeof jamb leaf and adjacent door knuckle. If the location is at thecenter of the hinge, one measurement per hinge at the centershall suffice. If the location is not at the center of
18、the hinge, twomeasurements, equally distant from the center of hinge aspracticable, shall be taken; the qualifying lateral measurementis the average of the two. Alternate methods of measuringvertical and lateral wear may be employed providing theycomply with X1.3.5.6.3.1.2 Measure and record force t
19、o overcome friction orout-of-balance condition. This shall be done 30 in. (762 mm)from the hinge pivot center after the door has been cycled 20times from the fully closed to the fully opened positions. Themeasurement shall be made perpendicular to the door and shallbe the force to get the door movin
20、g (static) and not the force tosustain motion (dynamic).6.3.1.3 Commence cycling at an average rate of 10 to 20cycles/min for test doors weighing 200 to 300 lb (91 to 136 kg)(Grades 14). For Double Weight Grade 1 type doors, cycle ata rate up to 10 cycles/min. Because of test scheduling demands,the
21、manufacturer or test laboratory shall be permitted to electto design an apparatus which is capable of safely withstandinghigher cycle rates. It is understood that any hinge subjected tohigher rates is being subjected to a more stringent test.6.3.1.4 During cycle testing, it is recommended that a log
22、 bekept of periodic cycle counts and wear measurements on eachtest sample. The frequency of data entries shall be agreed uponbetween the manufacturer and the testing laboratory.6.3.1.5 At the conclusion of the cycle test under the prede-termined grade level and frequency level in Table 1, measureeac
23、h sample in accordance with 6.3.1.1 to determine thedisplacement between leaves and knuckles. Record measure-ments of wear for all hinges.F1758 05 (2012)36.3.1.6 At the completion of the cycle test check the force toovercome friction in accordance with 6.3.1.2.6.4 Test Completion and Condition of Ac
24、ceptanceFor ahinge to be acceptable for the grade level and frequency levelbeing tested, the performance characteristics associated withthe cycle test shall not exceed any of the values in Table 1.6.5 Precision and BiasNo information is presented abouteither the precision or bias of the cycle test w
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF175820052012STANDARDTESTMETHODSFORDETENTIONHINGESUSEDONDETENTIONGRADESWINGINGDOORS 安全 等级 双开 弹簧门

链接地址:http://www.mydoc123.com/p-535571.html