ASTM F1681-2014 Standard Test Method for Determining Current Carrying Capacity of a Membrane Switch Circuit《测定薄膜开关线路载流能力的标准试验方法》.pdf
《ASTM F1681-2014 Standard Test Method for Determining Current Carrying Capacity of a Membrane Switch Circuit《测定薄膜开关线路载流能力的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F1681-2014 Standard Test Method for Determining Current Carrying Capacity of a Membrane Switch Circuit《测定薄膜开关线路载流能力的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F1681 07aF1681 14Standard Test Method forDetermining Current Carrying Capacity of a Conductor asPart of a Membrane Switch Circuit1This standard is issued under the fixed designation F1681; the number immediately following the designation indicates the year oforiginal adoption or, in the
2、 case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the current carrying capacity of a conduct
3、or as part of a membrane switch.1.2 This test method may be used to test a circuit to destruction, that is, to determine its maximum current carrying capacity,or it may be used to test the ability of a circuit to withstand a desired current level.1.3 This test method applies only to static condition
4、s, and does not apply to contact closure cycling of a membrane switch undercurrent load (test method forthcoming).1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate s
5、afety and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2F1578 Test Method for Contact Closure Cycling of a Membrane SwitchF1680 Test Method for Determining Circuit Resistance of a Membrane Switch3. Terminology3.1 Def
6、initions:3.1.1 conductor resistancethe measured electrical resistance through a circuit loop between two test points.3.1.2 DiscussionWhen a switch is included in that loop, it shall be closed” in accordance with Test Method F1680.3.1.3 current carrying capacity (CCC)the maximum level of electrical c
7、urrent that a circuit can conduct without sustainingdamage.3.1.4 membrane switcha momentary switching device in which at least one contact is on, or made of, a flexible substrate.3.1.5 power capacityelectrical power is defined as current voltage = V I (watts).3.1.6 test pointstwo preselected conduct
8、ive points in a circuit loop, possibly including a switch.4. Significance and Use4.1 Current carrying capacity is used by designers and manufacturers of electronic interface circuitry to ensure that themembrane switch can reliably handle the loads occurring in normal use and under extreme circumstan
9、ces. A thoroughunderstanding of CCC allows manufacturers to take it into account when developing design rules for membrane switches.4.2 Failures due to exceeding the CCC of a circuit may take the form of a significant change in conductor resistance, insulationbreakdown (shorts), or conductor breakdo
10、wn (opens).4.3 Since a number of design parameters, such as trace width, ink film thickness, etc. and heat transfer (mounting substrates,active cooling such as fans) affect the final test results, any conclusions should only be applied to specific designs, rather than toa general combination of mate
11、rials.1 This test method is under the jurisdiction of ASTM Committee F01 on Electronics and is the direct responsibility of Subcommittee F01.18 on Membrane Switches.Current edition approved Dec. 1, 2007Jan. 1, 2014. Published December 2007January 2014. Originally approved in 1996. Last previous edit
12、ion approved in 2007 asF168107.07a. DOI: 10.1520/F1681-07A.10.1520/F1681-14.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on th
13、e ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users co
14、nsult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14.4 Current carrying capacity tes
15、ts may be destructive and units that have been tested should be considered unreliable for futureuse.4.5 Current carrying capacity may be significantly different for static loads and dynamic (that is, cycling) loads. Failure modesare also generally different.4.6 The use of a thermocouple to monitor t
16、he temperature of the UUT may be helpful to monitor the progress of the test.4.7 Initial expected starting current should be calculated in advance to prevent damage to test equipment.5. Interferences5.1 The following parameters may affect the results of this test:5.1.1 Temperature,5.1.2 Relative hum
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF16812014STANDARDTESTMETHODFORDETERMININGCURRENTCARRYINGCAPACITYOFAMEMBRANESWITCHCIRCUIT 测定 薄膜开关

链接地址:http://www.mydoc123.com/p-535395.html