《ASTM F1558-1994(2015) Standard Guide for Characteristics for Adjunct Cervical Spine Immobilization Devices (ACSID)《辅助颈椎固定装置 (ACSID) 的标准特征指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM F1558-1994(2015) Standard Guide for Characteristics for Adjunct Cervical Spine Immobilization Devices (ACSID)《辅助颈椎固定装置 (ACSID) 的标准特征指南》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F1558 94 (Reapproved 2015)Standard Guide forCharacteristics for Adjunct Cervical Spine ImmobilizationDevices (ACSID)1This standard is issued under the fixed designation F1558; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revi
2、sion, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONThe objective of this guide is to begin to address the recognized need to support and immobilize the
3、components of the spine or spinal cord. Although this guide does not quantitatively addressperformance standards for this device, it does address the characteristics of the device(s) used toprovide support and immobilization of the components of the central nervous system for the patientsuspected of
4、 receiving trauma to that body system.1. Scope1.1 This guide establishes minimum standards for devicesdesignated here as adjunct cervical spine immobilization de-vice (ACSID); a lateral stabilizer for the head is an example ofthis type of device. The ACSID is designed to be used to assistin the immo
5、bilization of the cervical spine, by emergencymedical services personnel.1.2 This guide does not identify specific degrees of limita-tion of motion achieved by placement of an ACSID on apatient. Definitive requirements for immobilization of thespine, and, in particular, the degree of limitation asso
6、ciatedwith the use of an ACSID, have not been established in themedical literature.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and
7、determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2F1177 Terminology Relating to Emergency Medical Ser-vices2.2 OSHA Standard:20 CFR 1910.1030 Occupational Exposure to BloodbornePathogens; Final Rule32.3 Centers for Disease Control Standard
8、:Guidelines for Prevention of Transmission of HIV and HBVto Healthcare and Public Safety Workers43. Terminology3.1 Definitions:3.1.1 retention systeman adjunct to or an integral part ofthe primary platform that allows the patient to be securelyattached to that platform used in whatever configuration
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF155819942015STANDARDGUIDEFORCHARACTERISTICSFORADJUNCTCERVICALSPINEIMMOBILIZATIONDEVICESACSID 辅助

链接地址:http://www.mydoc123.com/p-535148.html