ASTM F1506-2017b Standard Performance Specification for Flame Resistant and Electric Arc Rated Protective Clothing Worn by Workers Exposed to Flames and Electric Arcs《暴露于火焰和电弧的工人穿的.pdf
《ASTM F1506-2017b Standard Performance Specification for Flame Resistant and Electric Arc Rated Protective Clothing Worn by Workers Exposed to Flames and Electric Arcs《暴露于火焰和电弧的工人穿的.pdf》由会员分享,可在线阅读,更多相关《ASTM F1506-2017b Standard Performance Specification for Flame Resistant and Electric Arc Rated Protective Clothing Worn by Workers Exposed to Flames and Electric Arcs《暴露于火焰和电弧的工人穿的.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F1506 17bStandard Performance Specification forFlame Resistant and Electric Arc Rated Protective ClothingWorn by Workers Exposed to Flames and Electric Arcs1This standard is issued under the fixed designation F1506; the number immediately following the designation indicates the year ofo
2、riginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This performance specification identifies minimum per-forman
3、ce requirements to determine the (a) arc rating offabrics, (b) flame resistance of fabrics and subassemblies, (c)mechanical durability of the fabrics and subassemblies, (d) theminimum garment construction and performance requirements,and (e) the garment labeling requirements for the completedprotect
4、ive clothing worn by workers exposed to flames andelectric arcs.1.1.1 The minimum requirements for garment labeling areintended to provide end users with adequate information toselect garments with the appropriate arc rating.1.1.2 End users are required to perform an assessment todetermine the level
5、 of hazard and the required arc rating of theprotective clothing for their individual hazards.1.1.2.1 The end user risk assessments are outside the scopeof this standard.1.2 This performance specification does not address coatedor laminated protective clothing commonly used for rainwearapplications
6、in an arc hazard environment. Performance re-quirements related to this category of protective clothing aredetailed in Specification F1891.1.3 This performance specification does not address handprotection. Performance and test requirements related to handprotection are detailed in OSHA1910.138, Spe
7、cification D120,and Test Method F2675/F2675M.1.4 The care and maintenance requirements for launderingelectric arc flash protective clothing are outside the scope ofthis standard. Refer to Guides F1449 or F2757 related toindustrial or home laundering.1.5 This standard should be used to evaluate and d
8、escribethe properties of materials, products, or assemblies in responseto heat and flame under controlled laboratory conditions. Itshould not be used to describe or appraise the fire hazard orfire risk of materials, products, or assemblies under actual fireconditions.1.5.1 The results of this evalua
9、tion may be used as elementsof a fire-risk assessment that takes into account all of thefactors that are pertinent to an assessment of the fire hazard ofa particular end use.1.6 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1
10、.7 The following precautionary caveat pertains only to thetest methods portion, Section 7, of this performance specifica-tion: This standard does not purport to address all of the safetyconcerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appro
11、priate safety,health, and environmental practices and determine the appli-cability of regulatory limitations prior to use.1.8 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevel
12、opment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D120 Specification for Rubber Insulating GlovesD123 Terminology Relating to TextilesD1424 Test Method for Tearin
13、g Strength of Fabrics byFalling-Pendulum (Elmendorf-Type) ApparatusD2262 Test Method for Tearing Strength of Woven Fabricsby the Tongue (Single Rip) Method (Constant-Rate-of-Traverse Tensile Testing Machine) (Withdrawn 1995)3D2724 Test Methods for Bonded, Fused, and LaminatedApparel Fabrics1This per
14、formance specification is under the jurisdiction of ASTM CommitteeF18 on Electrical Protective Equipment for Workers and is the direct responsibilityof Subcommittee F18.65 on Wearing Apparel.Current edition approved Nov. 15, 2017. Published January 2018. Originallyapproved in 1994. Last previous edi
15、tion approved in 2017 as F150617a. DOI:10.1520/F1506-17B.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The
16、 last approved version of this historical standard is referenced onwww.astm.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on stand
17、ardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.1D3786 Test Method for Bursting Strength of TextileFabricsDiaphragm Bursting Strength Test
18、er MethodD5034 Test Method for Breaking Strength and Elongation ofTextile Fabrics (Grab Test)D6413 Test Method for Flame Resistance of Textiles (Ver-tical Test)D7138 Test Method to Determine Melting Temperature ofSynthetic FibersF1449 Guide for Industrial Laundering of Flame, Thermal,and Arc Resista
19、nt ClothingF1891 Specification for Arc and Flame Resistant RainwearF1959/F1959M Test Method for Determining theArc Ratingof Materials for ClothingF2675/F2675M Test Method for DeterminingArc Ratings ofHand Protective Products Developed and Used for Elec-trical Arc Flash ProtectionF2757 Guide for Home
20、 Laundering Care and Maintenanceof Flame, Thermal and Arc Resistant Clothing2.2 AATCC Test Methods:4Method 61 Colorfastness to Washing, Domestic andLaundering, Commercial: AcceleratedMethod 132 Colorfastness to Dry-CleaningMethod 135 Dimensional Changes Automatic Home Laun-dering of Woven and Knitte
21、d FabricsMethod 158 Dimensional Changes on Drycleaning in Per-chloroethylene: Machine Method2.3 Federal Standards:29 CFR 1910.138 Hand Protection53. Terminology3.1 DefinitionsFor definitions of textile terms used in thisperformance specification, refer to Terminology D123.3.2 Definitions of Terms Sp
22、ecific to This Standard:3.2.1 afterflame, npersistent flaming of a material after theignition source has been removed.3.2.1.1 DiscussionIn arc testing, a visible flaming on ornear a test specimen which persists after the arc exposure hasended. The afterflame ceases when flaming is no longer visible.
23、3.2.2 afterflame time, nthe length of time for which amaterial continues to flame after the ignition source has beenremoved.3.2.2.1 DiscussionIn arc testing, the length of time forwhich a specimen continues to exhibit visible flaming asdetermined by a time display video recording of the specimenduri
24、ng arc testing.3.2.3 arc rating, nvalue attributed to materials that de-scribes their performance to exposure to an electrical arcdischarge.3.2.3.1 DiscussionThe arc rating is expressed in cal/cm2and is derived from the determined value of ATPV or EBT(should a material system exhibit a breakopen res
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF15062017BSTANDARDPERFORMANCESPECIFICATIONFORFLAMERESISTANTANDELECTRICARCRATEDPROTECTIVECLOTHINGWORNBYWORKERSEXPOSEDTOFLAMESANDELECTRICARCS

链接地址:http://www.mydoc123.com/p-535034.html