ASTM F1506-2010a Standard Performance Specification for Flame Resistant and Arc Rated Textile Materials for Wearing Apparel for Use by Electrical Workers Exposed to Momentary Elect.pdf
《ASTM F1506-2010a Standard Performance Specification for Flame Resistant and Arc Rated Textile Materials for Wearing Apparel for Use by Electrical Workers Exposed to Momentary Elect.pdf》由会员分享,可在线阅读,更多相关《ASTM F1506-2010a Standard Performance Specification for Flame Resistant and Arc Rated Textile Materials for Wearing Apparel for Use by Electrical Workers Exposed to Momentary Elect.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F1506 10aStandard Performance Specification forFlame Resistant and Arc Rated Textile Materials for WearingApparel for Use by Electrical Workers Exposed toMomentary Electric Arc and Related Thermal Hazards1This standard is issued under the fixed designation F1506; the number immediately
2、following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This perform
3、ance specification covers the flame resis-tance of textile materials to be used for wearing apparel for useby electrical workers exposed to momentary electric arc andrelated thermal hazards.NOTE 1This performance specification does not cover coated fabricscommonly used in rainwear.NOTE 2At present,
4、a bench scale arc test for laboratory use is notavailable. It is the intent of the committee to continue the search for anacceptable laboratory test based on either an electric arc exposure or anacceptable alternative, which will form the basis of a modification of thisperformance specification.1.2
5、Materials used for basic protection levels are covered.1.3 Protective properties relate to thermal exposure frommomentary arc and associated exposure to open flame andradiant heat. (See Appendix X1.)1.4 This performance specification covers wearing appareldesign characteristics that relate specifica
6、lly to protection fromexposure to momentary electric arc and that relate to the utilityof the wearing apparel.NOTE 3A number of other thermal test methods are under consider-ation and development and, when evaluated and proved effective byCommittee F18, will be incorporated in either this performanc
7、e specifi-cation or an appropriate alternative test method or specification.1.5 This standard should be used to evaluate and describethe properties of materials, products, or assemblies in responseto heat and flame under controlled laboratory conditions. Itshould not be used to describe or appraise
8、the fire hazard orfire risk of materials, products, or assemblies under actual fireconditions.1.5.1 The results of this evaluation may be used as elementsof a fire-risk assessment that takes into account all of thefactors that are pertinent to an assessment of the fire hazard ofa particular end use.
9、1.6 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.7 The following precautionary caveat pertains only to thetest methods portion, Section 7, of this performance specifica-tion: This standard does not purport to address all o
10、f the safetyconcerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety andhealth practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D123 Terminology Relating t
11、o TextilesD434 Test Method for Resistance to Slippage of Yarns inWoven Fabrics Using a Standard Seam3D1424 Test Method for Tearing Strength of Fabrics byFalling-Pendulum (Elmendorf-Type) ApparatusD2262 Test Method for Tearing Strength of Woven Fabricsby the Tongue (Single Rip) Method (Constant-Rate-
12、of-Traverse Tensile Testing Machine)3D2724 Test Methods for Bonded, Fused, and LaminatedApparel FabricsD3786 Test Method for Bursting Strength of TextileFabricsDiaphragm Bursting Strength Tester MethodD5034 Test Method for Breaking Strength and Elongationof Textile Fabrics (Grab Test)D6413 Test Meth
13、od for Flame Resistance of Textiles (Ver-tical Test)F1449 Guide for Industrial Laundering of Flame, Thermal,and Arc Resistant ClothingF1959/F1959M Test Method for Determining the Arc Rat-ing of Materials for Clothing1This performance specification is under the jurisdiction of ASTM CommitteeF18 on El
14、ectrical Protective Equipment for Workers and is the direct responsibilityof Subcommittee F18.65 on Wearing Apparel.Current edition approved Oct. 1, 2010. Published October 2010. Originallyapproved in 1994. Last previous edition approved in 2010 as F150610. DOI:10.1520/F1506-10A.2For referenced ASTM
15、 standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn. The last approved version of this historical standard is referencedon
16、 www.astm.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.2.2 AATCC Test Methods:4Method 61 Colorfastness to Washing, Domestic and Laun-dering, Commercial: AcceleratedMethod 132 Colorfastness to Dry-CleaningMethod 135 Dimensional
17、 Changes Automatic Home Laun-dering of Woven and Knitted FabricsMethod 158 Dimensional Changes on Drycleaning in Per-chloroethylene: Machine Method2.3 Federal Standard:5Test Method 191A, 15343. Terminology3.1 DefinitionsFor definitions of textile terms used in thisperformance specification, refer to
18、 Terminology D123.3.2 Definitions of Terms Specific to This Standard:3.2.1 afterflame, npersistent flaming of a material afterthe ignition source has been removed.3.2.1.1 DiscussionIn arc testing, a visible flaming on ornear a test specimen which persists after the arc exposure hasended. The afterfl
19、ame ceases when flaming is no longer visible.3.2.2 afterflame time, nthe length of time for which amaterial continues to flame after the ignition source has beenremoved.3.2.2.1 DiscussionIn arc testing, the length of time forwhich a specimen continues to exhibit a visible flaming asdetermined by a t
20、ime display video recording of the specimenduring arc testing.3.2.3 arc rating, nvalue attributed to materials that de-scribes their performance to exposure to an electrical arcdischarge.3.2.3.1 DiscussionThe arc rating is expressed in cal/cm2and is derived from the determined value of ATPV or EBT-(
21、should a material system exhibit a breakopen response belowthe ATPV value).3.2.4 arc thermal performance value (ATPV), nin arctesting, the incident energy on a material or a multilayer systemof materials that results in a 50 % probability that sufficientheat transfer through the tested specimen is p
22、redicted to causethe onset of a second-degree skin burn injury based on theStoll6curve, cal/cm2.3.2.5 basic protection levelthe level of protection pro-vided by flame-resistant materials that do not continue to burnafter exposure to and removal of a source of ignition (see 7.6).3.2.6 basic protectio
23、n level wearing apparelclothing in-tended for continuous wear for work activities in designatedlocations in which exposure to momentary electric arc andrelated radiant heat and open-flame sources is possible.3.2.7 breakopen threshold energy (EBT), nthe incidentenergy on a material or material system
24、 that results in a 50 %probability of breakopen.3.2.7.1 DiscussionThis is the value in J/cm2(cal/cm2)determined by use of logistic regression analysis representingthe energy at which breakopen of the layer occurred.3.2.8 design test, nfor arc and flame resistant textilematerials, one made on a sampl
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF15062010ASTANDARDPERFORMANCESPECIFICATIONFORFLAMERESISTANTANDARCRATEDTEXTILEMATERIALSFORWEARINGAPPARELFORUSEBYELECTRICALWORKERSEXPOSEDTOMOMENTARYELECTPDF

链接地址:http://www.mydoc123.com/p-535030.html