ASTM F1410-1998(2006) Standard Test Method for Measuring Maximum Functional Wet Volume of Utility Vacuum Cleaners《测量通用真空吸尘器最大功能湿容积的测试方法》.pdf
《ASTM F1410-1998(2006) Standard Test Method for Measuring Maximum Functional Wet Volume of Utility Vacuum Cleaners《测量通用真空吸尘器最大功能湿容积的测试方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F1410-1998(2006) Standard Test Method for Measuring Maximum Functional Wet Volume of Utility Vacuum Cleaners《测量通用真空吸尘器最大功能湿容积的测试方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 1410 98 (Reapproved 2006)An American National StandardStandard Test Method forMeasuring Maximum Functional Wet Volume of UtilityVacuum Cleaners1This standard is issued under the fixed designation F 1410; the number immediately following the designation indicates the year oforiginal ad
2、option or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method is applicable to any vacuum cleanerthat is classifie
3、d as a utility vac.1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are for informa-tion only.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this
4、standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Significance and Use2.1 This test method covers a procedure to determine themaximum functional wet volume that the utility vac is capableof collecting.3. Apparatu
5、s3.1 Voltmeter, to measure input to the cleaner, providingmeasurements accurate to within 61%.3.2 Voltage Regulator SystemThe regulator shall be ca-pable of maintaining the rated voltage (61 %) and frequency(61 Hz) with sinusoidal wave form.3.3 Temperature and Relative Humidity Indicators, to pro-vi
6、de temperature measurements accurate to within 61F (612C) and humidity measurements accurate to within 62%relative humidity.3.4 Weighing ScaleThe scale shall be accurate to 1 % offull scale and have a weighing capacity of at least 250 lb (113.4kg).4. Materials4.1 Water.5. Sampling5.1 Test a sample o
7、f each basic model until a 90 %confidence level (about the mean) is established within 65%of the mean value. Test a minimum of three samples. Select allsamples at random in accordance with good statistical practice.NOTE 1SeeAppendix X1 for method of determining 90 % confidencelevel.6. Conditioning6.
8、1 Test RoomThe test room should be maintained at70 6 5F (21 6 3C) and 45 to 55 % relative humidity.7. Procedure7.1 Equip the vac with a new filter.7.2 Weigh the empty vac including the power supply cord.(Do not include the hose or any accessories.)7.3 Unit must be on a level surface and the shut-off
9、 devicemust be in place if the unit is designed to be used with one.7.4 Level of the water to be picked up shall be lower thanthe floor level of vac such that no siphoning occurs.7.5 Tests are to be conducted at the nameplate voltage(61 %) and frequency (61 Hz), when measured at theappliance plug. F
10、or cleaners with dual nameplate voltageratings, conduct tests at the highest voltage.7.6 Using the largest hose supplied with the unit, vacuumwater into the vac-tank. Maintain a water pick up rate of 2gal/min throughout the filling cycle.7.7 Collect water with the vac until either one of thefollowin
11、g occurs:7.7.1 The unit stops collecting water, or7.7.2 Water overflows from the vac.7.8 Stop unit and disconnect hose from the vac. Any waterremaining in the hose shall not be included in the maximumfunctional volume.7.9 Weigh the filled vac, including the power supply cord.7.10 Calculate the maxim
12、um functional volume by dividingthe weight of the water collected by the weight per gallon ofwater as follows:1This test method is under the jurisdiction ofASTM Committee F11 on VacuumCleaners and is the direct responsibility of Subcommittee F11.23 on Filtration.Current edition approved July 1, 2006
13、. Published July 2006. Originally approvedin 1992. Last previous edition approved in 2003 as F 1410 98 (2003).1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.volume, gal 5weight lb! vac filled 2 weight lb! vac empty8.328 lb/gal7.11 R
14、ecord the maximum functional wet volume in gallons(litres) to the nearest tenth.7.12 Repeat steps 7.1 through 7.12 two more times. Theaverage of the three tests represents the maximum wet func-tional volume that the utility vac is capable of collecting.8. Precision and Bias28.1 PrecisionThese statem
15、ents are based on an interlabo-ratory test involving six laboratories and four units. The rangeof maximum functional volume of the units was from 3.8 to13.5 gal.8.1.1 Repeatability (Single-Operator-Laboratory, Multi-day):8.1.1.1 Repeatability for wet volume values of 5 gal andunder, within a laborat
16、ory divided by the average (coefficientof variation) was found to be 4.5 % or less. Two values from asample of three should be considered suspect (at the 95 %confidence level) if they differ by more than 12.8 %.NOTE 2The percent difference = (larger smaller)/(larger) 3 100.8.1.1.2 Repeatability for
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF141019982006STANDARDTESTMETHODFORMEASURINGMAXIMUMFUNCTIONALWETVOLUMEOFUTILITYVACUUMCLEANERS 测量 通用

链接地址:http://www.mydoc123.com/p-534824.html