ASTM F1350-2008 Standard Specification for Wrought 18Chromium-14Nickel-2 5Molybdenum Stainless Steel Surgical Fixation Wire (UNS S31673)《锻造18铬-14镍-2 5钼不锈钢外科固定用线标准规范(UNS S31673)》.pdf
《ASTM F1350-2008 Standard Specification for Wrought 18Chromium-14Nickel-2 5Molybdenum Stainless Steel Surgical Fixation Wire (UNS S31673)《锻造18铬-14镍-2 5钼不锈钢外科固定用线标准规范(UNS S31673)》.pdf》由会员分享,可在线阅读,更多相关《ASTM F1350-2008 Standard Specification for Wrought 18Chromium-14Nickel-2 5Molybdenum Stainless Steel Surgical Fixation Wire (UNS S31673)《锻造18铬-14镍-2 5钼不锈钢外科固定用线标准规范(UNS S31673)》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 1350 08Standard Specification forWrought 18Chromium-14Nickel-2.5Molybdenum StainlessSteel Surgical Fixation Wire (UNS S31673)1This standard is issued under the fixed designation F 1350; the number immediately following the designation indicates the year oforiginal adoption or, in the
2、case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification covers the chemical, mechanical, andmetallurgical requirements for t
3、he manufacture of wrought 18chromium-14 nickel-2.5 molybdenum stainless steel in theform of surgical fixation wire.1.2 The values stated in SI units are to be regarded as thestandard. The inch-pound values in parentheses are for infor-mation only.2. Referenced Documents2.1 ASTM Standards:2A 555/A 55
4、5M Specification for General Requirements forStainless Steel Wire and Wire RodsE8 Test Methods for Tension Testing of Metallic MaterialsE29 Practice for Using Significant Digits in Test Data toDetermine Conformance with SpecificationsF86 Practice for Surface Preparation and Marking of Me-tallic Surg
5、ical ImplantsF 138 Specification for Wrought 18Chromium-14Nickel-2.5Molybdenum Stainless Steel Bar and Wire for SurgicalImplants (UNS S31673)F 981 Practice for Assessment of Compatibility of Bioma-terials for Surgical Implants with Respect to Effect ofMaterials on Muscle and Bone2.2 USP Standard:3No
6、nabsorbable Surgical Suture, U.S. Pharmacopeia2.3 ISO Standard:4ISO 9001 Quality Management SystemRequirements2.4 American Society for Quality Standard:5ASQ C1 Specification of General Requirements for a Qual-ity Program3. General Requirements for Delivery3.1 In addition to the requirements of this
7、specification, allrequirements of the current editions of Specifications A 555/A 555M and F 138 apply.3.2 In cases where a conflict exists between this specifica-tion and the standards listed in Section 2, this specificationshall take precedence.4. Terminology4.1 Definitions of Terms Specific to Thi
8、s Standard:4.1.1 lot, nthe total number of mill products producedfrom the same melt heat under the same conditions at essen-tially the same time.5. Ordering Information5.1 Inquiries and orders for material under this specificationshall include the following information:5.1.1 Quantity,5.1.2 ASTM desi
9、gnation and date of issue,5.1.3 Material requirements,5.1.4 Mechanical properties,5.1.5 Form,5.1.6 Dimensional requirements, including diameter anddiameter tolerance,5.1.7 Surface condition and handling,5.1.8 Special tests (if applicable), and5.1.9 Other requirements.6. Material Requirements6.1 The
10、starting material used to make fixation wire mustmeet the requirements of Specification F 138.6.2 Surgical fixation wire shall conform to the specifiedchemical requirements of Specification F 138. Conformancewith this standard shall be so identified by suitable packaging,labeling, or both.1This spec
11、ification is under the jurisdiction of ASTM Committee F04 onMedical and Surgical Materials and Devices and is the direct responsibility ofSubcommittee F04.12 on Metallurgical Materials.Current edition approved May 1, 2008. Published June 2008. Originallyapproved in 1991. Last previous edition approv
12、ed in 2002 as F 1350 02.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from U.S. Pharmacopeia (US
13、P), 12601 Twinbrook Pkwy., Rockville,MD 20852-1790, http:/www.usp.org.4Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.5Available from American Society for Quality (ASQ), 600 N. Plankinton Ave.,Milwaukee, WI 53203, http:/w
14、ww.asq.org.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.7. Mechanical Requirements7.1 Surgical fixation wire shall conform to the appropriatemechanical properties s
15、pecified in Table 1.7.2 Perform tension tests in accordance with Test MethodsE8using a 254 mm (10 in.) gage length and a cross-head speedof 254 mm/min (10 in./min). Should any of the test specimensnot meet the specified requirements, test two additional testpieces representative of the same lot, in
16、the same manner, foreach failed test piece. The lot shall be considered in complianceonly if all additional test pieces meet the specified require-ments.7.3 Tensile test results for which any specimen fracturesoutside the gage length shall be considered acceptable if theelongation meets the minimum
17、requirements specified in Table1. Refer to subsections 7.11.4 and 7.11.5 of Test Methods E8.If the elongation is less than the minimum requirement, discardthe test and retest. Retest one specimen for each specimen thatdid not meet the minimum requirement.7.4 The wire shall meet the requirements of t
18、he latestversion of USP for Nonabsorbable Surgical Sutures, whentested in accordance with 7.2.8. Dimensional Requirements8.1 Surgical fixation wire shall be fabricated in accordancewith the dimensions and tolerances specified in Table 1.8.2 Unless otherwise specified, size tolerances are plus andmin
19、us as shown in Table 1. When required by the purchaser,round wire tolerances may be specified all plus and nothingminus, or all minus and nothing plus, or any combination ofplus and minus if the total spread in size tolerance is not lessthan the total spread shown in Table 1.8.3 The maximum out-of-r
20、ound tolerance for round wire isone-half of the size tolerance given in Table 1.9. Surface Condition Requirements9.1 Surgical fixation wire is usually furnished in the bright-annealed condition. Other surface finishes shall be specified asagreed to between supplier and purchaser.9.2 The surface of s
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF13502008STANDARDSPECIFICATIONFORWROUGHT18CHROMIUM14NICKEL25MOLYBDENUMSTAINLESSSTEELSURGICALFIXATIONWIREUNSS31673

链接地址:http://www.mydoc123.com/p-534716.html