ASTM F1160-2005(2011)e1 Standard Test Method for Shear and Bending Fatigue Testing of Calcium Phosphate and Metallic Medical and Composite Calcium Phosphate Metallic Coatings《磷酸钙金属.pdf
《ASTM F1160-2005(2011)e1 Standard Test Method for Shear and Bending Fatigue Testing of Calcium Phosphate and Metallic Medical and Composite Calcium Phosphate Metallic Coatings《磷酸钙金属.pdf》由会员分享,可在线阅读,更多相关《ASTM F1160-2005(2011)e1 Standard Test Method for Shear and Bending Fatigue Testing of Calcium Phosphate and Metallic Medical and Composite Calcium Phosphate Metallic Coatings《磷酸钙金属.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F1160 05 (Reapproved 2011)1Standard Test Method forShear and Bending Fatigue Testing of Calcium Phosphateand Metallic Medical and Composite Calcium Phosphate/Metallic Coatings1This standard is issued under the fixed designation F1160; the number immediately following the designation ind
2、icates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEUnits information was editorially corrected in J
3、anuary 2012.1. Scope1.1 This test method covers the procedure for determiningthe shear and bending fatigue performance of calcium phos-phate coatings and of porous and nonporous metallic coatingsand for determining the bending fatigue performance ofmetallic coatings oversprayed with calcium phosphat
4、e. Thistest method has been established based on plasma-sprayedtitanium and plasma-sprayed hydroxylapatite coatings. Theefficacy of this test method for other coatings has not beenestablished. In the shear fatigue mode, this test methodevaluates the adhesive and cohesive properties of the coatingon
5、a metallic substrate. In the bending fatigue mode, this testmethod evaluates both the adhesion of the coating as well asthe effects that the coating may have on the substrate material.These methods are limited to testing in air at ambient tempera-ture. These test methods are not intended for applica
6、tion infatigue tests of components or devices; however, the testmethod which most closely replicates the actual loadingconfiguration is preferred.1.2 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact eq
7、uivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may result in non-conformancewith the standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user
8、 of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E6 Terminology Relating to Methods of Mechanical TestingE206 Definitions of Terms Relating to Fatigue Testing and
9、the Statistical Analysis of Fatigue Data; Replaced byE 11503E466 Practice for Conducting Force Controlled ConstantAmplitude Axial Fatigue Tests of Metallic MaterialsE467 Practice for Verification of Constant Amplitude Dy-namic Forces in an Axial Fatigue Testing SystemE468 Practice for Presentation o
10、f Constant Amplitude Fa-tigue Test Results for Metallic MaterialsE1012 Practice for Verification of Test Frame and SpecimenAlignment Under Tensile and Compressive Axial ForceApplication3. Definitions3.1 The definitions of terms relating to shear and fatiguetesting appearing in Terminology E6 shall b
11、e considered asapplying to the terms used in this test method.4. Summary of Test Method4.1 Shear Fatigue Testing:4.1.1 The intent of the shear fatigue test is to determine theadhesive or cohesive strength, or both, of the coating.4.1.2 This test method is designed to allow the coating tofail at eith
12、er the coating/substrate interface, within the coating,or at the glue/coating interface between the coating and theadhesive bonding agent used to transmit the load to the coating.4.2 Bending Fatigue Testing:1This test method is under the jurisdiction of ASTM Committee F04 on Medicaland Surgical Mate
13、rials and Devices and is the direct responsibility of SubcommitteeF04.15 on Material Test Methods.Current edition approved Oct. 1, 2011. Published January 2012. Originallyapproved in 1991. Last previous edition approved in 2005 as F1160 05. DOI:10.1520/F1160-05R11E01.2For referenced ASTM standards,
14、visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn. The last approved version of this historical standard is referencedon www.astm.or
15、g.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.2.1 The primary intent of the bending fatigue test is toquantify the effect that the coating has on the substrate it isapplied to. Secondarily, it may be used to provide a subjectiv
16、eevaluation of coating adhesion, (that is, spalling resistance,cracking resistance, and so forth).4.2.2 This test method is designed to first provide a substratefatigue strength to serve as a baseline to assess the effects of thecoating on the resulting fatigue strength of the system.5. Significance
17、 and Use5.1 The shear and bending fatigue tests are used to deter-mine the effect of variations in material, geometry, surfacecondition, stress, and so forth, on the fatigue resistance ofcoated metallic materials subjected to direct stress for up to 107cycles. These tests may be used as a relative g
18、uide to theselection of coated materials for service under condition ofrepeated stress.5.2 In order that such basic fatigue data be comparable,reproducible, and can be correlated among laboratories, it isessential that uniform fatigue practices be established.5.3 The results of the fatigue test may
19、be used for basicmaterial property design. Actual components should not betested using these test methods.6. Equipment Characteristics6.1 Equipment characteristics shall be in accordance withPractice E466, Section 7. See also Practices E467 and E1012and Definitions E206.6.2 Shear Fatigue Test Grips:
20、6.2.1 GeneralVarious types of grips may be used totransmit the load to the specimens by the testing machine. Toensure axial shear stress, it is important that the specimen axiscoincide with the centerline of the heads of the testing machineand that the coating test plane be parallel to the axial loa
21、d. Anydeparture from this requirement (that is, any eccentric loading)will introduce bending stresses that are not included in theusual stress calculation (force/cross-sectional area).6.2.2 A drawing of a typical gripping device for the testassembly is shown in Fig. 1.6.2.3 Fig. 2 shows a drawing of
22、 the adaptor to mate theshear fixture to the tensile machine6.2.4 Figs. 3 and 4 show a schematics of the test setup.6.3 Bending Fatigue Test GripsThere are a variety oftesting machines that may be employed for this test (that is,rotating beam fatigue machines and axial fatigue machines).The gripping
23、 method for each type of equipment shall bedetermined by either the manufacturer of that equipment(rotating beam machines) or the user.7. Adhesive Bonding Materials7.1 Adhesive Bonding AgentA polymeric adhesive bond-ing agent in film form, or filled viscous adhesive cement, shallbe identified and sh
24、all meet the following requirements.7.1.1 The bonding agent shall be capable of bonding thecoating on the test specimen components with an adhesiveshear strength that is at least 34.5 MPa 5000 psi or as great asthe minimum required adhesion or cohesion strength of thecoating, whichever is greater.7.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF116020052011E1STANDARDTESTMETHODFORSHEARANDBENDINGFATIGUETESTINGOFCALCIUMPHOSPHATEANDMETALLICMEDICALANDCOMPOSITECALCIUMPHOSPHATEMETALLICCOATINGS

链接地址:http://www.mydoc123.com/p-534323.html