ASTM E966-2018 red 6875 Standard Guide for Field Measurements of Airborne Sound Attenuation of Building Facades and Facade Elements《建筑外墙和立面元件的空气传播声音衰减的现场测量标准指南》.pdf
《ASTM E966-2018 red 6875 Standard Guide for Field Measurements of Airborne Sound Attenuation of Building Facades and Facade Elements《建筑外墙和立面元件的空气传播声音衰减的现场测量标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM E966-2018 red 6875 Standard Guide for Field Measurements of Airborne Sound Attenuation of Building Facades and Facade Elements《建筑外墙和立面元件的空气传播声音衰减的现场测量标准指南》.pdf(17页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E966 101E966 18Standard Guide forField Measurements of Airborne Sound Attenuation ofBuilding Facades and Facade Elements1This standard is issued under the fixed designation E966; the number immediately following the designation indicates the year oforiginal adoption or, in the case of r
2、evision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1 NOTEEditorial changes were made throughout in April 2011.INTRODUCTIONThis guide provides methods to measure
3、 the sound isolation of a room from outdoor sound, and toevaluate the sound transmission or apparent sound transmission through a particular facade of theroom or an element of that faade such as a window or door. Measurements from outdoors to indoorsdiffer from measurements between two rooms. The ou
4、tdoor sound field is not diffuse and thetransmission of that sound through the structure is a function of the outdoor sound angle of incidence.The outdoor-indoor transmission loss values obtained with this guide are not expected to be the sameas that obtained in laboratory or other tests between two
5、 rooms using diffuse incident sound. At thistime, there are insufficient data available to specify a single, standard measurement procedure suitablefor all field situations. For this reason, this guide provides alternative test procedures for themeasurements of facade field level reduction and trans
6、mission loss.This guide is part of a set of standards for evaluating the sound isolation of rooms and the soundinsulating properties of building elements. Others in this set cover the airborne sound transmission lossof an isolated partition element in a controlled laboratory environment (Test Method
7、 E90), thelaboratory measurement of impact sound transmission through floors (Test Method E492), themeasurement of airborne sound transmission in buildings (Test Method E336), the measurement ofimpact sound transmission in buildings (Test Method E1007), and the measurement of soundtransmission throu
8、gh a common plenum between two rooms (Test Method E1414).1. Scope1.1 This guide may be used to determine the outdoor-indoor noise reduction (OINR), which is the difference in sound pressurelevel between the free-field level outdoors in the absence of the structure and the resulting sound pressure le
9、vel in a room. Eithera loudspeaker or existing traffic noise or aircraft noise can be used as the source. The outdoor sound field geometry must bedescribed and calculations must account for the way the outdoor level is measured. These results are used with ClassificationE1332 to calculate the single
10、 number rating outdoor-indoor noise isolation class, OINIC. Both OINR and OINIC can vary withoutdoor sound incidence angle.1.2 Under controlled circumstances where a single faade is exposed to the outdoor sound, or a faade element such as a dooror window has much lower transmission loss than the res
11、t of the faade, an outdoor-indoor transmission loss, OITL(), or apparentoutdoor-indoor transmission loss,AOITL(), may be measured using a loudspeaker source.These results are a function of the angleof incidence of the sound field. By measuring with sound incident at many angles, an approximation to
12、the diffuse fieldtransmission loss as measured between two rooms can be obtained. The results may be used to predict interior sound levels ininstallations similar to that tested when exposed to an outdoor sound field similar to that used during the measurement. The singlenumber ratings of apparent o
13、utdoor-indoor transmission class, AOITC(), using AOITL() and field outdoor-indoor transmissionclass, FOITC(), using OITL() may be calculated using Classification E1332. These ratings also may be calculated with the dataobtained from receiving room sound pressure measurements performed at several inc
14、idence angles as discussed in 8.6.1 This guide is under the jurisdiction ofASTM Committee E33 on Building and EnvironmentalAcoustics and is the direct responsibility of Subcommittee E33.03 on SoundTransmission.Current edition approved Sept. 1, 2010Jan. 15, 2018. Published December 2010January 2018.
15、Originally approved in 1984. Last previous edition approved in 20042010as E966 04.E966 101. DOI: 10.1520/E0966-10E01.10.1520/E0966-18.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous versio
16、n. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International
17、, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States11.3 To cope with the variety of outdoor incident sound field geometries that are encountered in the field, six testing techniquesare presented. These techniques and their general applicability are summarized in Tab
18、le 1 and Figs. 1-6. The room, faade, orfaade element declared to be under test is referred to as the specimen.1.4 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes(excluding those in tables and figures) shall not be considered as r
19、equirements of the standard.1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of
20、this standard to establish appropriate safety safety, health, and healthenvironmental practices and determine theapplicability of regulatory limitations prior to use.1.6 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes(excluding t
21、hose in tables and figures) shall not be considered as requirements of the standard.1.7 This international standard was developed in accordance with internationally recognized principles on standardizationestablished in the Decision on Principles for the Development of International Standards, Guide
22、s and Recommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2C634 Terminology Relating to Building and Environmental AcousticsE90 Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Buildi
23、ng Partitions and ElementsE336 Test Method for Measurement of Airborne Sound Attenuation between Rooms in BuildingsE492 Test Method for Laboratory Measurement of Impact Sound Transmission Through Floor-Ceiling Assemblies Using theTapping MachineE1007 Test Method for Field Measurement of Tapping Mach
24、ine Impact Sound Transmission Through Floor-CeilingAssembliesand Associated Support StructuresE1332 Classification for Rating Outdoor-Indoor Sound AttenuationE1414 Test Method for Airborne Sound Attenuation Between Rooms Sharing a Common Ceiling PlenumE2235 Test Method for Determination of Decay Rat
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME9662018RED6875STANDARDGUIDEFORFIELDMEASUREMENTSOFAIRBORNESOUNDATTENUATIONOFBUILDINGFACADESANDFACADEELEMENTS

链接地址:http://www.mydoc123.com/p-533861.html