ASTM E966-2010e1 9375 Standard Guide for Field Measurements of Airborne Sound Insulation of Building Facades and Facade Elements《建筑物表面和表面构件的空气隔音的现场测量标准指南》.pdf
《ASTM E966-2010e1 9375 Standard Guide for Field Measurements of Airborne Sound Insulation of Building Facades and Facade Elements《建筑物表面和表面构件的空气隔音的现场测量标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM E966-2010e1 9375 Standard Guide for Field Measurements of Airborne Sound Insulation of Building Facades and Facade Elements《建筑物表面和表面构件的空气隔音的现场测量标准指南》.pdf(15页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E966 101Standard Guide forField Measurements of Airborne Sound Attenuation ofBuilding Facades and Facade Elements1This standard is issued under the fixed designation E966; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision
2、, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEEditorial changes were made throughout in April 2010.INTRODUCTIONThis guide provides methods to measure the sou
3、nd isolation of a room from outdoor sound, and toevaluate the sound transmission or apparent sound transmission through a particular facade of theroom or an element of that faade such as a window or door. Measurements from outdoors to indoorsdiffer from measurements between two rooms. The outdoor so
4、und field is not diffuse and thetransmission of that sound through the structure is a function of the outdoor sound angle of incidence.The outdoor-indoor transmission loss values obtained with this guide are not expected to be the sameas that obtained in laboratory or other tests between two rooms u
5、sing diffuse incident sound. At thistime, there are insufficient data available to specify a single, standard measurement procedure suitablefor all field situations. For this reason, this guide provides alternative test procedures for themeasurements of facade field level reduction and transmission
6、loss.This guide is part of a set of standards for evaluating the sound isolation of rooms and the soundinsulating properties of building elements. Others in this set cover the airborne sound transmission lossof an isolated partition element in a controlled laboratory environment (Test Method E90), t
7、helaboratory measurement of impact sound transmission through floors (Test Method E492), themeasurement of airborne sound transmission in buildings (Test Method E336), the measurement ofimpact sound transmission in buildings (Test Method E1007), and the measurement of soundtransmission through a com
8、mon plenum between two rooms (Test Method E1414).1. Scope1.1 This guide may be used to determine the outdoor-indoornoise reduction (OINR), which is the difference in soundpressure level between the free-field level outdoors in theabsence of the structure and the resulting sound pressure levelin a ro
9、om. Either a loudspeaker or existing traffic noise oraircraft noise can be used as the source. The outdoor soundfield geometry must be described and calculations must ac-count for the way the outdoor level is measured. These resultsare used with Classification E1332 to calculate the singlenumber rat
10、ing outdoor-indoor noise isolation class, OINIC.Both OINR and OINIC can vary with outdoor sound incidenceangle.1.2 Under controlled circumstances where a single faade isexposed to the outdoor sound, or a faade element such as adoor or window has much lower transmission loss than the restof the faade
11、, an outdoor-indoor transmission loss, OITL(u), orapparent outdoor-indoor transmission loss, AOITL(u), may bemeasured using a loudspeaker source. These results are afunction of the angle of incidence of the sound field. Bymeasuring with sound incident at many angles, an approxima-tion to the diffuse
12、 field transmission loss as measured betweentwo rooms can be obtained. The results may be used to predictinterior sound levels in installations similar to that tested whenexposed to an outdoor sound field similar to that used duringthe measurement. The single number ratings of apparentoutdoor-indoor
13、 transmission class,AOITC(u), usingAOITL(u)and field outdoor-indoor transmission class, FOITC(u), usingOITL(u) may be calculated using Classification E1332. Theseratings also may be calculated with the data obtained fromreceiving room sound pressure measurements performed atseveral incidence angles
14、as discussed in 8.6.1.3 To cope with the variety of outdoor incident sound fieldgeometries that are encountered in the field, six testing tech-niques are presented. These techniques and their generalapplicability are summarized in Table 1 and Figs. 1-6. The1This guide is under the jurisdiction of AS
15、TM Committee E33 on Building andEnvironmentalAcoustics and is the direct responsibility of Subcommittee E33.03 onSound Transmission.Current edition approved Sept. 1, 2010. Published December 2010. Originallyapproved in 1984. Last previous edition approved in 2004 as E966 04. DOI:10.1520/E0966-10.1Co
16、pyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.room, faade, or faade element declared to be under test isreferred to as the specimen.1.4 The values stated in SI units are to be regarded asstandard. No other units of measurement are inc
17、luded in thisstandard.1.5 This standard does not purport to address the safetyconcerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety andhealth practices and determine the applicability of regulatorylimitations prior to use.1.6
18、The text of this standard references notes and footnoteswhich provide explanatory material. These notes and footnotes(excluding those in tables and figures) shall not be consideredas requirements of the standard.2. Referenced Documents2.1 ASTM Standards:2C634 Terminology Relating to Building and Env
19、ironmentalAcousticsE90 Test Method for Laboratory Measurement of AirborneSound Transmission Loss of Building Partitions and Ele-mentsE336 Test Method for Measurement of Airborne SoundAttenuation between Rooms in BuildingsE492 Test Method for Laboratory Measurement of ImpactSound Transmission Through
20、 Floor-Ceiling AssembliesUsing the Tapping MachineE1007 Test Method for Field Measurement of TappingMachine Impact Sound Transmission Through Floor-Ceiling Assemblies and Associated Support StructuresE1332 Classification for Rating Outdoor-Indoor Sound At-tenuationE1414 Test Method for Airborne Soun
21、d Attenuation Be-tween Rooms Sharing a Common Ceiling PlenumE2235 Test Method for Determination of Decay Rates forUse in Sound Insulation Test Methods2.2 ANSI Standards:3S1.11 Specification for Octave-Band and Fractional-OctaveAnalog and Digital Filter SetsS1.40 Specifications and Verification Proce
22、dures for SoundCalibratorsS1.43 Specifications for Integrating -Averaging SoundLevel Meters2.3 IEC Standards:3IEC 61672 Electroacoustics - Sound Level MetersIEC 60942 Electroacoustics - Sound Calibrators3. Terminology3.1 Definitionsfor acoustical terms used in this guide, seeTerminology C634.3.2 Def
23、initions of Terms Specific to This Standard:3.2.1 apparent outdoor-indoor transmission class, apparentAOITL(u), nof a building faade or faade element at aspecified angle u or range of angles, a single-number ratingcalculated in accordance with Classification E1332 usingmeasured values of apparent ou
24、tdoor-indoor transmission loss.3.2.2 apparent outdoor-indoor transmission loss, AOITL(u),(dB), , nof a building facade or facade element in a specifiedfrequency band, for a source at a specified angle u or range ofangles as measured from the normal to the center of thespecimen surface, the value of
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME9662010E19375STANDARDGUIDEFORFIELDMEASUREMENTSOFAIRBORNESOUNDINSULATIONOFBUILDINGFACADESANDFACADEELEMENTS

链接地址:http://www.mydoc123.com/p-533860.html