《ASTM E887-2015 red 8474 Standard Test Method for Silica in Refuse-Derived Fuel (RDF) and RDF Ash《垃圾衍生燃料 (RDF) 和其灰烬中二氧化硅的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E887-2015 red 8474 Standard Test Method for Silica in Refuse-Derived Fuel (RDF) and RDF Ash《垃圾衍生燃料 (RDF) 和其灰烬中二氧化硅的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E887 88 (Reapproved 2009)E887 15Standard Test Method forSilica in Refuse-Derived Fuel (RDF) and RDF Ash1This standard is issued under the fixed designation E887; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year
2、 of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of silica in RDF, refuse-derived fuel (RDF), RDF ash, fly ash, bottom as
3、h, or slag.1.2 The test method is an acid dehydration gravimetric procedure and is independent of interferences.1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.1.4 This standard does not purport to address all of the safe
4、ty concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use. For hazard statement, see Section 6.2. Referenced Documents2.1 ASTM Standards
5、:2D1193 Specification for Reagent WaterE791 Test Method for Calculating Refuse-Derived Fuel Analysis Data from As-Determined to Different BasesE829 Practice for Preparing Refuse-Derived Fuel (RDF) Laboratory Samples for Analysis (Withdrawn 2002)33. Summary of Test Method3.1 Silicon compounds in RDF
6、ash, fly ash, bottom ash, or slag are dissolved by alkali fusion and dehydrated with hydrochloricacid (HCl). Dehydration is completed by ignition, and the silica is volatilized as silicon tetrafluoride.4. Apparatus4.1 Analytical Balance, capable of weighing to 0.0001 g.4.2 Muffle FurnaceThe furnace
7、shall have an operating temperature of up to 1200C.4.3 Hot Plate Plate, Microwave Digester, or Steam Bath.4.4 Platinum Crucibles, 35 to 85-mL capacity.4.5 Graphite Crucibles, 35 to 85-mL capacity.4.6 Fused Quartz Dishes, 35 to 85-mL capacity.5. Reagents and Materials5.1 Purity of ReagentsReagent gra
8、de chemicals shall be used in this test. Unless otherwise indicated, it is intended that allreagents shall conform to the specifications of the Committee on Analytical Reagents of the American Chemical Society wheresuch specifications are available.4 Other grades may be used, provided it is first as
9、certained that the reagent is of sufficiently highpurity to permit its use without lessening the accuracy of the determination.1 This test method is under the jurisdiction of ASTM Committee D34 on Waste Management and is the direct responsibility of Subcommittee D34.03 on Treatment,Recovery and Reus
10、e.Current edition approved July 1, 2009Sept. 1, 2015. Published August 2009October 2015. Originally approved in 1982. Last previous edition approved in 20042009 asE 887 88E887 88 (2009). (2004). DOI: 10.1520/E0887-88R09.10.1520/E0887-15.2 For referencedASTM standards, visit theASTM website, www.astm
11、.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3 The last approved version of this historical standard is referenced on www.astm.org.4 Reagent Chemicals, American Chemical
12、 Society Specifications, American Chemical Society, Washington, DC. For Suggestions on the testing of reagents not listed bythe American Chemical Society, see Analar Standards for Laboratory Chemicals, BDH Ltd., Poole, Dorset, U.K., and the United States Pharmacopeia and NationalFormulary, U.S. Phar
13、macopeial Convention, Inc. (USPC), Rockville, MD.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurat
14、ely, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
15、15.2 Purity of WaterUnless otherwise indicated, reference to water shall be understood to mean at least Type III reagent waterconforming to Specification D1193.5.3 Sodium Carbonate (Na2CO3), anhydrous powder.5.4 Hydrochloric Acid (HCl), concentrated, sp gr 1.19.5.5 Hydrochloric Acid (1 + 3),Mix 1 vo
16、lume of concentrated HCl with 3 volumes of water.5.6 Hydrochloric Acid (1 + 1)Mix 1 volume of concentrated HCl with 1 volume of water.5.7 Hydrochloric Acid (1 + 99)Mix 1 volume of concentrated HCl with 99 volumes of water.5.8 Sulfuric Acid (1 + 1)Mix 1 volume of concentrated sulfuric acid (H2SO4, sp
17、 gr 1.84) with 1 volume of water.5.9 Hydrofluric Acid (HF), concentrated 48 to 51 %.6. Hazards6.1 Due to the origins of RDF in municipal waste, common sense dictates that precautions should be observed when conductingtests on the samples. Recommended hygienicsafety practices include use of suitable
18、gloves when handling RDF; wearing dustmasks (NIOSH-approved type), especially while milling RDF samples; conducting tests under negative pressure hoods whenpossible; and washing hands upon completion of activity and before eating or smoking.7. Sampling7.1 Refuse-Derived Fuel (RDF):NOTE 1ASTM Subcomm
19、ittee E38.01 is currently in the process of developing procedures for sampling RDF.7.1.1 RDF products are frequently nonhomogeneous. For this reason, significant care should be exercised to obtain arepresentative laboratory sample from the RDF lot to be characterized.7.1.2 The sampling method for th
20、ese procedures should be based on agreement between involved parties.7.1.3 The laboratory sample must be air-dried and particle size reduced to pass a 0.5-mm screen for analysis. This proceduremust be performed carefully to preserve the samples representative characteristics (other than particle siz
21、e) while preparing theanalysis sample to be used in this procedure (see Practice E829).7.2 Refuse-Derived Fuel Ash, Fly Ash, Bottom Ash, or SlagThe method of sampling for this procedure should be based onagreement between involved parties.8. Sample Preparation8.1 Refuse-Derived Fuel:8.1.1 Weigh accu
22、rately 30 to 50 g of RDF analysis sample as prepared in 6.1 into a conditioned and preweighed fused quartzdish.8.1.2 Spread out the analysis sample of RDF in a layer not over 38.1 mm (112 in.) in depth.8.1.3 Place the dish in the muffle at a low temperature (not greater than 100C) and gradually heat
23、 to redness at such a rate asto avoid mechanical loss from too rapid expulsion of volatile matter.8.1.4 Complete the conversion to ash at a temperature of 800 to 900C (1470 to 1650F).8.1.5 Cool in a desiccator and stir the ash to ensure homogeneity of particle sizes. Be careful not to lose any ash f
24、rom the dishduring this stirring.8.1.6 Spread the ash in a thin layer in the dish, and ignite in a stream of oxygen for 112 h at 800 to 850C (1470 to 1560F)to ensure complete and uniform oxidation of the ash.8.1.7 Cool the ash to room temperature in a desiccator.8.1.8 Weigh the dish and the ash.8.1.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME8872015RED8474STANDARDTESTMETHODFORSILICAINREFUSEDERIVEDFUELRDFANDRDFASH 垃圾 衍生 燃料 RDF 灰烬 二氧化硅 标准

链接地址:http://www.mydoc123.com/p-533731.html