ASTM E874-2011 red 9375 Standard Practice for Adhesive Bonding of Aluminum Facings to Nonmetallic Honeycomb Core for Shelter Panels《保护板用非金属蜂窝状芯体铝盖面的粘合剂粘结标准规程》.pdf
《ASTM E874-2011 red 9375 Standard Practice for Adhesive Bonding of Aluminum Facings to Nonmetallic Honeycomb Core for Shelter Panels《保护板用非金属蜂窝状芯体铝盖面的粘合剂粘结标准规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E874-2011 red 9375 Standard Practice for Adhesive Bonding of Aluminum Facings to Nonmetallic Honeycomb Core for Shelter Panels《保护板用非金属蜂窝状芯体铝盖面的粘合剂粘结标准规程》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation:E87410a Designation: E874 11Standard Practice forAdhesive Bonding of Aluminum Facings to NonmetallicHoneycomb Core for Shelter Panels1This standard is issued under the fixed designation E874; the number immediately following the designation indicates the year oforiginal adoption or, in t
2、he case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This
3、 practice describes the materials, processes, and quality controls to be used in the manufacture of adhesive-bonded,aluminum-faced, nonmetallic-honeycomb-core sandwich panels for tactical shelters.1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parenthes
4、es are mathematicalconversions to SI units that are provided for information only and are not considered standard.1.3 This standard does not purport to address the safety concerns, if any, associated with its use. It is the responsibility of theuser of this standard to establish appropriate safety a
5、nd health practices and determine the applicability of regulatory limitationsprior to use.2. Referenced Documents2.1 ASTM Standards:2B209 Specification for Aluminum and Aluminum-Alloy Sheet and PlateC297/C297M Test Method for Flatwise Tensile Strength of Sandwich ConstructionsD1781 Test Method for C
6、limbing Drum Peel for AdhesivesE864 Practice for Surface Preparation of Aluminum Alloys to Be Adhesively Bonded in Honeycomb Shelter PanelsE865 Specification for Structural Film Adhesives for Honeycomb Sandwich PanelsE866 Specification for Corrosion-Inhibiting Adhesive Primer for Aluminum Alloys to
7、Be Adhesively Bonded in HoneycombShelter PanelsE990 Specification for Core-Splice Adhesive for Honeycomb Sandwich Structural PanelsE1091 Specification for Nonmetallic Honeycomb Core for Use in Shelter PanelsE1826 Specification for Low Volatile Organic Compound (VOC) Corrosion-Inhibiting Adhesive Pri
8、mer for Aluminum Alloysto Be Adhesively Bonded Specification for Low Volatile Organic Compound (VOC) Corrosion-Inhibiting Adhesive Primer forAluminum Alloys to Be Adhesively BondedE2004 Test Method for Facing Cleavage of Sandwich Panels2.2 Military Standards:3MIL-STD-105 Sampling Procedures and Tabl
9、es for Inspection by Attributes2.3 Federal Standards:3Fed. Std. No. 209 Clean Room and Work Station Requirements, Controlled Environment3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 excessive corrosion, nsurface corrosion that is not removed by cleaning as described in Pract
10、ice E864.3.1.2 gouge, na surface defect in which material has been removed and that causes a decrease in strength in a highly stressedarea.3.1.3 nominal pressure, nthe intended operating pressure.3.1.4 nominal temperature, nthe intended operating temperature.1This practice is under the jurisdiction
11、of ASTM Committee E06 on Performance of Buildings and is the direct responsibility of Subcommittee E06.53 on Materials andProcesses for Durable Rigidwall Relocatable Structures.Current edition approved Nov.Sept. 1, 2010.2011. Published December 2010.October 2011. Originally approved in 1982. Last pr
12、evious edition approved in 2010 asE874 10a. DOI: 10.1520/E0874-10A.10.1520/E0874-11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary
13、page on the ASTM website.3Available from Standardization Documents Order Desk, DODSSP, Bldg. 4, Section D, 700 Robbins Ave., Philadelphia, PA 19111-5098, http:/dodssp.daps.dla.mil.1This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of wha
14、t changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the
15、 official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.1.5 tapping test, na nondestructive evaluation procedure for detecting panel delamination in which the outer skin of thepanels is tapped with a hammer or coin.3.1.5.
16、1 DiscussionChanges in acoustic emissions resulting from tapping can be associated with delamination andnondelaminated sections of panel.4. Significance and Use4.1 The formation of reproducible, durable-adhesive bonds in structural units requires great care in the selection of materials,the preparat
17、ion of the surfaces of the parts to be bonded, and the performance of the steps in the bonding process. Experience hasshown that adhesive bonding carried out in accordance with this practice produces relatively reproducible bonds.5. Facilities5.1 Panel-Assembly-Layup AreaThe panel-assembly-lay-up ar
18、ea is an enclosed, environmentally controlled area that iscontinuously controlled for temperature, relative humidity, and concentration of airborne particles. The environmentally controlledarea shall be maintained at a temperature of 75 6 10F (24 6 6C) and not more than 50 % relative humidity. The t
19、emperatureand relative humidity shall be recorded continuously.All incoming and recirculated air shall be filtered to control airborne particles.The air handling equipment shall provide at least five air changes per hour in the environmentally controlled area. The filters shallensure that the partic
20、le count within the environmentally controlled area will not exceed 200 000 particles/ft3(7 3 106particles/m3) of size 1 m and larger. The air pressure differential between the environmentally controlled area and adjacent areasshall be monitored continuously and recorded at least twice weekly. The a
21、ir pressure in the environmentally controlled area shallbe maintained above that of adjacent areas by a minimum of 0.015 in. H2O (3.7 Pa). The particle count shall be monitored inaccordance with Fed. Std. No. 209. The recorders shall be calibrated every six months. The environmentally controlled are
22、a shallbe conspicuously identified at all entrances as limited access. Unnecessary traffic within the environmentally controlled area shallnot be permitted. Eating and smoking within the environmentally controlled area shall not be permitted and the environmentallycontrolled area shall be so posted.
23、 All materials, tools, and equipment used in the environmentally controlled area shall be clean,low shed, and free of lint, oil, and grease. The application of oil, grease, mold release agents, or other possible contaminants withinthe environmentally controlled area shall be prohibited. The interior
24、, exposed surfaces of the environmentally controlled area shallbe nonshedding and easily cleaned. The floor shall be sealed and cleaned daily to minimize dust generation. No preparations suchas insertion of foam into honeycomb core, or cleaning other than by filtered vacuum, shall take place in the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME8742011RED9375STANDARDPRACTICEFORADHESIVEBONDINGOFALUMINUMFACINGSTONONMETALLICHONEYCOMBCOREFORSHELTERPANELS

链接地址:http://www.mydoc123.com/p-533705.html