ASTM E736-2000(2006) Standard Test Method for Cohesion Adhesion of Sprayed Fire-Resistive Materials Applied to Structural Members《结构构件上喷涂的防火材料的粘附性 粘结性的标准试验方法》.pdf
《ASTM E736-2000(2006) Standard Test Method for Cohesion Adhesion of Sprayed Fire-Resistive Materials Applied to Structural Members《结构构件上喷涂的防火材料的粘附性 粘结性的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E736-2000(2006) Standard Test Method for Cohesion Adhesion of Sprayed Fire-Resistive Materials Applied to Structural Members《结构构件上喷涂的防火材料的粘附性 粘结性的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 736 00 (Reapproved 2006)Standard Test Method forCohesion/Adhesion of Sprayed Fire-Resistive MaterialsApplied to Structural Members1This standard is issued under the fixed designation E 736; the number immediately following the designation indicates the year oforiginal adoption or, in
2、the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 Th
3、is test method covers a procedure for measuring thecohesion/adhesion or bond strength (tensile) perpendicular tothe surface of sprayed fire-resistive material (SFRM) applied torigid backing. These fire-resistive materials include sprayedfibrous and cementitious materials. The test method is appli-ca
4、ble to both laboratory and field procedures as indicated inSection 7.1.2 The values stated in SI units are to be regarded as thestandard. The values in parentheses are for information only.1.3 This standard does not purport to address all of thesafety problems, if any, associated with its use. It is
5、 theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E84 Test Method for Surface Burning Characteristics ofBuilding MaterialsE119 Test M
6、ethods for Fire Tests of Building Constructionand MaterialsE 605 Test Methods for Thickness and Density of SprayedFire-Resistive Material (SFRM) Applied to StructuralMembers3. Summary of Test Method3.1 The cohesion/adhesion is determined using a metal orplastic cap with a hook attached. The cap is a
7、ttached to theSFRM with a suitable adhesive. An increasing load, measuredby a scale, is applied manually until failure occurs.4. Significance and Use4.1 The intent of this test method is to determine a propertyof SFRM that may be used to provide an indication of itsin-place serviceability. Satisfact
8、ory performance of SFRMapplied to structural members and assemblies depends upon itsability to withstand the various influences that may occurduring construction and during the life of the structure, as wellas upon its satisfactory performance under fire conditions.5. Apparatus5.1 Fig. 1 illustrates
9、 a suitable apparatus.5.2 Bottle Screw Cap,3metal or rigid plastic 51 mm to 83mm (2 in. to 314 in.) in diameter and 12 mm (12 in.) in nominaldepth. A hook shall be attached at the center. Where deckprofile does not allow the use of an 83-mm (314-in.) diametercap due to area restriction, a minimum 51
10、-mm (2-in.) diametercap shall be used.5.3 Adhesive, single or two component, suitable for adher-ing cap to SFRM.45.4 Weighing Scale, spring type (fish hook), with a capacitysuitable for the SFRM being tested (typically 12 kg to 30 kg(26 to 66 lb) capacity). The accuracy shall be within 0.1 kg (14lb)
11、.5.5 Galvanized Steel Sheet, 1.5 mm (0.060 in. (16 ga) thick,300 mm (12 in.) square, cleaned with solvent to remove any oilfrom surface to be sprayed.5.6 Drying Oven, capable of maintaining temperature andhumidity conditions during the specimen curing cycle, inaccordance with the SFRM manufacturers
12、published require-ments.6. Sampling6.1 This test method requires the application of SFRM inaccordance with manufacturers published instructions. The1This test method is under the jurisdiction of ASTM Committee E06 onPerformance of Buildings and is the direct responsibility of Subcommittee E06.21on S
13、erviceability.Current edition approved Jan. 1, 2006. Published January 2006. Originallyapproved in 1980. Last previous edition approved in 2000 as E 736 00.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of AST
14、MStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Refer to Appendix X1.2 for a list of bottle screw cap supply houses that havebeen found satisfactory for this purpose. Many local suppliers are also available.4Suitable adhesives are commercially availabl
15、e. Refer to Appendix X1.1 for alist of adhesive supply houses that have been found satisfactory for this purpose.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.apparatus, materials, and procedures used to spray apply theSFRM for thi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME73620002006STANDARDTESTMETHODFORCOHESIONADHESIONOFSPRAYEDFIRERESISTIVEMATERIALSAPPLIEDTOSTRUCTURALMEMBERS

链接地址:http://www.mydoc123.com/p-533422.html