ASTM E679-2004(2011) 1850 Standard Practice for Determination of Odor and Taste Thresholds By a Forced-Choice Ascending Concentration Series Method of Limits《用强制选择提升浓度限值系列法测定气味和味道阈.pdf
《ASTM E679-2004(2011) 1850 Standard Practice for Determination of Odor and Taste Thresholds By a Forced-Choice Ascending Concentration Series Method of Limits《用强制选择提升浓度限值系列法测定气味和味道阈.pdf》由会员分享,可在线阅读,更多相关《ASTM E679-2004(2011) 1850 Standard Practice for Determination of Odor and Taste Thresholds By a Forced-Choice Ascending Concentration Series Method of Limits《用强制选择提升浓度限值系列法测定气味和味道阈.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E679 04 (Reapproved 2011)Standard Practice forDetermination of Odor and Taste Thresholds By a Forced-Choice Ascending Concentration Series Method of Limits1This standard is issued under the fixed designation E679; the number immediately following the designation indicates the year ofori
2、ginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONThe obtaining of odor and taste thresholds requires the sensor
3、y responses of a selected group ofindividuals called panelists. These thresholds may be determined in order to note the effect of variousadded substances on the odor and taste of a medium. They may also be determined in order tocharacterize and compare the odor or taste sensitivity of individuals or
4、 groups.It is recognized that precise threshold values for a given substance do not exist in the same sensethat values of vapor pressure exist. The ability to detect a substance by odor or taste is influenced byphysiological factors and criteria used in producing a response by the panelist. The para
5、meters ofsample presentation introduce further variations. Thus, the flowrate of a gaseous, odorous sample hasan influence on the detectability of an odor. However, a concentration range exists below which theodor or taste of a substance will not be detectable under any practical circumstances, and
6、above whichindividuals with a normal sense of smell or taste would readily detect the presence of the substance.The threshold determined by this practice is not the conventional group threshold (the stimulus leveldetectable with a probability of 0.5 by 50 % of the population) as obtained by Practice
7、 E1432, butrather a best estimate not far therefrom. The bias of the estimate depends on the concentration scalesteps chosen and on the degree to which each panelists threshold is centered within the range ofconcentrations he or she receives. The user also needs to keep in mind the very large degree
8、 of randomerror associated with estimating the probability of detection from only 50 to 100 3-AFC presentations.1. Scope1.1 This practice describes a rapid test for determiningsensory thresholds of any substance in any medium.1.2 It prescribes an overall design of sample preparation anda procedure f
9、or calculating the results.1.3 The threshold may be characterized as being either (a)only detection (awareness) that a very small amount of addedsubstance is present but not necessarily recognizable, or (b)recognition of the nature of the added substance.1.4 The medium may be a gas, such as air, a l
10、iquid, such aswater or some beverage, or a solid form of matter. The mediummay be odorless or tasteless, or may exhibit a characteristicodor or taste per se.1.5 This practice describes the use of a multiple forced-choice sample presentation method in an ascending concentra-tion series, similar to th
11、e method of limits.1.6 Physical methods of sample presentation for thresholddetermination are not a part of this practice, and will depend onthe physical state, size, shape, availability, and other propertiesof the samples.1.7 It is recognized that the degree of training received by apanel with a pa
12、rticular substance may have a profound influ-ence on the threshold obtained with that substance (1).21.8 Thresholds determined by using one physical method ofpresentation are not necessarily equivalent to values obtainedby another method.2. Referenced Documents2.1 ASTM Standards:3D1292 Test Method f
13、or Odor in WaterE544 Practices for Referencing Suprathreshold Odor Inten-sityE1432 Practice for Defining and Calculating Individual and1This practice is under the jurisdiction of ASTM Committee E18 on SensoryEvaluation and is the direct responsibility of Subcommittee E18.04 on Fundamen-tals of Senso
14、ry.Current edition approved Aug. 1, 2011. Published August 2011. Originallyapproved in 1979. Last previous edition approved in 2004 as E679 04. DOI:10.1520/E0679-04R11.2The boldface numbers in parentheses refer to the list of references at the end ofthis practice.3For referenced ASTM standards, visi
15、t the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-29
16、59, United States.Group Sensory Thresholds from Forced-Choice Data Setsof Intermediate Size2.2 CEN Standards:4EN 13725 Air QualityDetermination of Odour Concen-tration Using Dynamic Dilution Olfactometry2.3 ISO Standards:5ISO 13301 Sensory AnalysisMethodologyGeneralGuidance for Measuring Odour, Flav
17、our and Taste Detec-tion Thresholds by a Three Alternative Forced Choice(3AFC) Procedure3. Terminology3.1 Definitions:3.1.1 samplea material in any form that may or may notexhibit an odor or taste, depending on the amount of odorousor sapid components that it may contain.3.1.2 mediumany material use
18、d to dissolve, disperse, orsorb odorous or sapid material whose threshold is to bemeasured.3.1.3 blank samplea quantity of the medium containingno added odorous or sapid material.3.1.4 test samplethe medium to which an odorous orsapid material has been added at a known concentration.3.1.5 detection
19、thresholdthe lowest concentration of asubstance in a medium relating to the lowest physical intensityat which a stimulus is detected as determined by the best-estimate criterion.3.1.6 recognition thresholdthe lowest concentration of asubstance in a medium relating to the lowest physical intensityat
20、which a stimulus is recognized as determined by thebest-estimate criterion.3.1.7 best-estimate criterionan interpolated concentrationvalue, but not necessarily the concentration value that wasactually presented. In this practice it is the geometric mean ofthe last missed concentration and the next (
21、adjacent) higherconcentration.3.1.8 panelistsindividuals whose odor or taste thresholdsare being evaluated, or who are utilized to determine the odoror taste threshold of the substance of interest.3.1.9 ascending scale of concentrationsa series of in-creasing concentrations of an odorous or sapid su
22、bstance in achosen medium.3.1.10 scale stepsdiscrete concentration levels of a sub-stance in a medium, with concentrations increased by the samefactor per step throughout the scale.3.1.11 3-alternative forced choice (3-AFC) presentationaset consisting of one test sample and two blank samples (asappl
23、ied to this practice).3.1.12 geometric meanthe nth root of the product ofterms. In this method, the terms are concentration values.4. Summary of Practice4.1 A series of test samples is prepared by dispersing thesubstance whose threshold is to be determined in the mediumof interest. This concentratio
24、n scale should increase in geomet-ric increments so that any two adjacent concentration steps areseparated by a constant factor. At each concentration step, twoblank samples consisting of the medium only are madeavailable to the panelist. The blank and test samples areencoded so that there is no vis
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME679200420111850STANDARDPRACTICEFORDETERMINATIONOFODORANDTASTETHRESHOLDSBYAFORCEDCHOICEASCENDINGCONCENTRATIONSERIESMETHODOFLIMITS

链接地址:http://www.mydoc123.com/p-533301.html