ASTM E592-1999(2004) Standard Guide to Obtainable ASTM Equivalent Penetrameter Sensitivity for Radiography of Steel Plates 1 4 to 2 in [6 to 51 mm] Thick with X Rays and 1 to 6 in .pdf
《ASTM E592-1999(2004) Standard Guide to Obtainable ASTM Equivalent Penetrameter Sensitivity for Radiography of Steel Plates 1 4 to 2 in [6 to 51 mm] Thick with X Rays and 1 to 6 in .pdf》由会员分享,可在线阅读,更多相关《ASTM E592-1999(2004) Standard Guide to Obtainable ASTM Equivalent Penetrameter Sensitivity for Radiography of Steel Plates 1 4 to 2 in [6 to 51 mm] Thick with X Rays and 1 to 6 in .pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 592 99 (Reapproved 2004)Standard Guide toObtainable ASTM Equivalent Penetrameter Sensitivity forRadiography of Steel Plates14 to 2 in. 6 to 51 mm Thickwith X Rays and 1 to 6 in. 25 to 152 mm Thick withCobalt-601This standard is issued under the fixed designation E 592; the number imme
2、diately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 Thi
3、s guide to obtainable equivalent penetrameter sensi-tivity covers the minimum penetrameter thicknesses for whichthe image of the 1T and 2T holes is visible for a few practicalradiographic conditions. The values represent near optimumsensitivity for flat steel plates. Radiographic conditions thatgive
4、 higher values of scatter buildup from the specimen orbackscattered radiation at the image plane will give poorersensitivity.1.2 Eight radiographs that illustrate sensitivities obtainablewith practical radiographic systems are included as adjuncts tothis guide and may be obtained from ASTM.1.3 The v
5、alues stated in inch-pound units are to be regardedas the standard. The values given in brackets are for informa-tion only.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro
6、-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E 746 Test Method for Determining Relative Image QualityResponse of Industrial Radiographic FilmE 999 Guide for Controlling the Quality of Industrial
7、 Ra-diographic Film ProcessingE 1025 Practice for Design, Manufacture, and MaterialGrouping Classification of Hole-Type Image Quality Indi-cators (IQI) Used for RadiologyE 1316 Terminology for Nondestructive Examinations2.2 ISO Standard:ISO 7004 PhotographyIndustrial Radiographic FilmsDetermination
8、of ISO Speed, ISO Average Gradient, andISO Gradients G2 adn G4 When Exposed to X- andGamma-Radiation32.3 Military Standard:MIL-STD-271 Nondestructive Testing Requirements forMetals42.4 ASTM Adjuncts:Guide for Equivalent Penetrameter Sensitivity Between XRays and Cobalt-6053. Terminology3.1 Definitio
9、ns: For definitions of terms used in thisstandard, refer to Terminology E 1316, Section D.4. Significance and Use4.1 A key consideration with any radiographic system is itscapability to resolve detail (that is, sensitivity). The degree ofobtainable sensitivity with a given system is dependent uponse
10、veral radiographic parameters such as source energy level,film type, type and thickness of intensifying screens, exposure(density), etc. This guide permits the user to estimate thedegree of sensitivity that may be obtained with X rays andcobalt-60 gamma rays when using a prescribed set of radio-grap
11、hic parameters. This guide may also be used in conjunc-tion with Test Method E 746 to provide a basis for developingdata for evaluation of a users specific system. This data mayassist a user in determining appropriate parameters for obtain-ing desired degrees of radiographic system sensitivity. An1T
12、his guide is under the jurisdiction of ASTM Committee E07 on Nondestruc-tive Testing and is the direct responsibility of Subcommittee E07.02 on ReferenceRadiographs.Current edition approved July 1, 2004. Published July 2004. Originally approvedin 1977. Last previous edition approved in 1999 as E 592
13、 - 99.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (
14、ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036.4Available from Standardization Documents Order Desk, Bldg. 4 Section D, 700Robbins Ave., Philadelphia, PA 19111-5094, Attn: NPODS.5Available from ASTM Headquarters. Order RRE0592.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, W
15、est Conshohocken, PA 19428-2959, United States.alternate to this approach is the use of those adjunct radio-graphic illustrations detailed in Section 6.5. Procedure5.1 Sensitivity for14 to 2-in. 6 to 51-mm Thick Steel UsingX Rays:5.1.1 The values of sensitivity were determined from astatistical stud
16、y of visibility of images of penetrameter holes.Near 100 % certainty of seeing the image of a hole on anyradiograph was taken as the criterion for determining sensitiv-ity. Most radiographs will show slightly better sensitivity thanindicated in Figs. 1-3 because of the statistical nature ofrecording
17、 information from a beam of X rays but occasionally,one will not show quite as good sensitivity.5.1.2 Fig. 1 illustrates obtainable equivalent penetrametersensitivity (see Appendix X1 of Practice E 1025) for fourX-ray films. The films are identified by reciprocal roentgenspeed when exposed in accord
18、ance with ISO 7004 in a 200-kVrange, and processed in accordance with the manufacturersrecommendations (see Guide E 999).Film No. Speed1172 4.03 1.24 0.355.1.3 The radiographic exposure conditions were: 36-in.914-mm focus-film distance, 5-mil 0.13-mm front and10-mil 0.25-mm back lead screens, 20 mAm
19、in exposure, andkilovoltage adjusted to give a density of near 2.0.5.1.4 Most high-quality industrial X-ray films intended fordirect or lead screen exposure, that are exposed and developedaccordingly to give these speed values, will provide similarillustrations of sensitivity. Interpolation will giv
20、e illustrationsof sensitivity for speeds obtained with other film systems.5.1.5 In Fig. 2 the data are presented to show the thinnestpenetrameter for which the image of the 2T hole will be visible.The intersection of the line for a particular steel thickness andthe line for a given film projected on
21、to the abscissa gives thebest obtainable equivalent penetrameter sensitivity. The inter-section projected to the left ordinate gives the minimumpenetrameter marking (thickness in mils) in accordance withPractice E 1025 for which the image of the 2T hole will beNOTE 1See 5.1.3 for exposure conditions
22、.FIG. 1 Obtainable Penetrameter Sensitivity for14 to 2-in. 6 to 51-mm Thick Steel When Radiographing with X Rays.NOTE 1See 5.1.3 for exposure conditions.FIG. 2 Penetrameter Sensitivity and Minimum PenetrameterMarkings for Showing the 2T Hole When Radiographing14 to2-in. 6 to 51-mm Thick Steel with X
23、 Rays.E 592 99 (2004)2visible. The right ordinate gives the minimum marking inaccordance with MIL-STD-271 for which the image of the 2Thole will be visible.5.1.6 Fig. 3 gives the ASTM and military markings forwhich the image of the 1T hole will be visible.5.1.7 To take an example, on Fig. 2 the inte
24、rsection of thecurve for 1-in. 25-mm thick steel and for Film No. 2 showsthat the penetrameter sensitivity is 1.45 %. The minimumASTM penetrameter thickness that will show the 2T holeimage is 15. The corresponding military marking is 0.75 (seedashed lines). On Fig. 3 the sensitivity is, of course, 1
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME59219992004STANDARDGUIDETOOBTAINABLEASTMEQUIVALENTPENETRAMETERSENSITIVITYFORRADIOGRAPHYOFSTEELPLATES14TO2IN6TO51MMTHICKWITHXRAYSAND1TO6INPDF

链接地址:http://www.mydoc123.com/p-533111.html