ASTM E580 E580M-2014 0010 Standard Practice for Installation of Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels in Areas Subject to Earthquake Ground Motions《安装地震地.pdf
《ASTM E580 E580M-2014 0010 Standard Practice for Installation of Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels in Areas Subject to Earthquake Ground Motions《安装地震地.pdf》由会员分享,可在线阅读,更多相关《ASTM E580 E580M-2014 0010 Standard Practice for Installation of Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels in Areas Subject to Earthquake Ground Motions《安装地震地.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E580/E580M 14Standard Practice forInstallation of Ceiling Suspension Systems for AcousticalTile and Lay-in Panels in Areas Subject to EarthquakeGround Motions1This standard is issued under the fixed designation E580/E580M; the number immediately following the designation indicates the y
2、earof original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. D
3、epartment of Defense.1. Scope*1.1 This practice covers the installation of suspended sys-tems for acoustical tile and lay-in panels and their additionalrequirements for two groups of buildings that are constructedto resist the effects of earthquake motions as defined by ASCE7 and the International B
4、uilding Code. These groupings are forSeismic Design Category C and Seismic Design Categories D,E and F.1.2 The authority having jurisdiction shall determine theapplicability of this practice.1.3 Specification C635 and Practice C636 cover suspensionsystems and their installation without special regar
5、d to seismiclateral restraint needs. They remain applicable and shall befollowed when this practice is specified.1.4 Ceilings less than or equal to 144 square feet andsurrounded by walls connected to the structure above areexempt from the requirements of this practice.1.5 This practice is not intend
6、ed to stifle research anddevelopment of new products or methods. This practice is notintended to prevent the installation of any material or prohibitany design or method of construction not prescribed in thispractice, provided that any such alternative has been substan-tiated by verifiable engineeri
7、ng data or full-scale dynamictesting that is acceptable to the authority having jurisdiction.1.6 Ceiling areas of 1000 ft292.9 m2 or less shall beexempt from the lateral force bracing requirements of 5.2.8.1.7 Ceilings constructed of gypsum board which is screw ornail attached to suspended members t
8、hat support a ceiling onone level extending from wall to wall shall be exempt from therequirements of this practice.1.8 Free floating ceilings (those not attached directly to anystructural walls) supported by chains or cables from thestructure are not required to satisfy the seismic force require-me
9、nts provided they meet the following requirements:1.8.1 The design load for such items shall equal 1.4 timesthe vertical operating weight.1.8.2 Seismic interaction effects shall be considered inaccordance with 5.7.1.8.3 The connection to the structure shall allow a 360range of motion in the horizont
10、al plane.1.9 The values stated in either inch-pound or SI units are tobe regarded as standard. Within the text, the SI units are shownin brackets. The values stated in each system are not exactequivalents; therefore, each system shall be used independentlyof the other. Combining values from the two
11、systems result innonconformance with the specification.1.10 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bilit
12、y of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C635 Specification for the Manufacture, Performance, andTesting of Metal Suspension Systems for Acoustical Tileand Lay-in Panel CeilingsC636 Practice for Installation of Metal Ceiling SuspensionSystems for Acoustical
13、 Tile and Lay-In Panels2.2 Other Standards:ASCE 7 Minimum Design Loads for Buildings and OtherStructures31This practice is under the jurisdiction of ASTM Committee E33 on Buildingand Environmental Acoustics and is the direct responsibility of SubcommitteeE33.04 on Application of Acoustical Materials
14、 and Systems.Current edition approved Jan. 15, 2014. Published March 2014. Originallyapproved in 1976. Last previous edition approved in 2011 as E580 11b. DOI:10.1520/E0580_E0580M-14.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME580E580M20140010STANDARDPRACTICEFORINSTALLATIONOFCEILINGSUSPENSIONSYSTEMSFORACOUSTICALTILEANDLAYINPANELSINAREASSUBJECTTOEARTHQUAKEGROUNDMOTIONS

链接地址:http://www.mydoc123.com/p-533093.html