《ASTM E580 E580M-2011 red 8860 Standard Practice for Installation of Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels in Areas Subject to Earthquake Ground Motions《在.pdf》由会员分享,可在线阅读,更多相关《ASTM E580 E580M-2011 red 8860 Standard Practice for Installation of Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels in Areas Subject to Earthquake Ground Motions《在.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation:E580/E580M10a Designation: E580/E580M 11Standard Practice forInstallation of Ceiling Suspension Systems for AcousticalTile and Lay-in Panels in Areas Subject to EarthquakeGround Motions1This standard is issued under the fixed designation E580/E580M; the number immediately following the d
2、esignation indicates the yearof original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use
3、 by agencies of the Department of Defense.1. Scope*1.1 This practice covers the installation of suspended systems for acoustical tile and lay-in panels and their additionalrequirements for two groups of buildings that are constructed to resist the effects of earthquake motions as defined by ASCE 7 a
4、ndthe International Building Code. These groupings are for Seismic Design Category C and Seismic Design Categories D, E and F.1.2 The authority having jurisdiction shall determine the applicability of this practice.1.3 Specification C635 and Practice C636 cover suspension systems and their installat
5、ion without special regard to seismiclateral restraint needs. They remain applicable and shall be followed when this practice is specified.1.4 Ceilings less than or equal to 144 square feet and surrounded by walls connected to the structure above are exempt fromthe requirements of this practice.1.5
6、This practice is not intended to stifle research and development of new products or methods. This practice is not intendedto prevent the installation of any material or prohibit any design or method of construction not prescribed in this practice, providedthat any such alternative has been substanti
7、ated by verifiable engineering data or full-scale dynamic testing that is acceptable tothe authority having jurisdiction.1.6 Ceiling areas of 1000 ft292.9 m2 or less shall be exempt from the lateral force bracing requirements of 5.2.8.1.7 Ceilings constructed of gypsum board which is screw or nail a
8、ttached to suspended members that support a ceiling on onelevel extending from wall to wall shall be exempt from the requirements of this practice.1.8 Free floating ceilings (those not attached directly to any structural walls) supported by chains or cables from the structureare not required to sati
9、sfy the seismic force requirements provided they meet the following requirements:1.8.1 The design load for such items shall equal 1.4 times the vertical operating weight.1.8.2 Seismic interaction effects shall be considered in accordance with 5.7.1.8.3 The connection to the structure shall allow a 3
10、60 range of motion in the horizontal plane.1.9 The values stated in either inch-pound or SI units are to be regarded as standard. Within the text, the SI units are shownin brackets. The values stated in each system are not exact equivalents; therefore, each system shall be used independently of theo
11、ther. Combining values from the two systems result in nonconformance with the specification.1.10 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health prac
12、tices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C635 Specification for the Manufacture, Performance, and Testing of Metal Suspension Systems for Acoustical Tile and Lay-inPanel CeilingsC636 Practice for Installation of Metal Ceil
13、ing Suspension Systems for Acoustical Tile and Lay-In Panels2.2 Other Standards:1This practice is under the jurisdiction of ASTM Committee E33 on Building and Environmental Acoustics and is the direct responsibility of Subcommittee E33.04 onApplication of Acoustical Materials and Systems.Current edi
14、tion approved Oct. 1, 2010.March 15, 2011. Published October 2010.March 2011. Originally approved in 1976. Last previous edition approved in 2010 asE580 10a. DOI: 10.1520/E0580_E0580M-10A1.2For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at servi
15、ceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.1This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME580E580M2011RED8860STANDARDPRACTICEFORINSTALLATIONOFCEILINGSUSPENSIONSYSTEMSFORACOUSTICALTILEANDLAYINPANELSINAREASSUBJECTTOEARTHQUAKEGROUNDMOTIONS

链接地址:http://www.mydoc123.com/p-533088.html