ASTM E562-2005e1 752 Standard Test Method for Determining Volume Fraction by Systematic Manual Point Count.pdf
《ASTM E562-2005e1 752 Standard Test Method for Determining Volume Fraction by Systematic Manual Point Count.pdf》由会员分享,可在线阅读,更多相关《ASTM E562-2005e1 752 Standard Test Method for Determining Volume Fraction by Systematic Manual Point Count.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 562 05e1Standard Test Method forDetermining Volume Fraction by Systematic Manual PointCount1This standard is issued under the fixed designation E 562; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last
2、revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.e1NOTEEquation 3 and A1.11 were editorially revised in February 2008.INTRODUCTIONThis test method may be used to determine the volume
3、fraction of constituents in an opaquespecimen using a polished, planar cross section by the manual point count procedure.1. Scope1.1 This test method describes a systematic manual pointcounting procedure for statistically estimating the volumefraction of an identifiable constituent or phase from sec
4、tionsthrough the microstructure by means of a point grid.1.2 The use of automatic image analysis to determine thevolume fraction of constituents is described in Practice E 1245.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsi
5、bility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E3 Guide for Preparation of Metallographic SpecimensE7 Terminology Relating to MetallographyE 4
6、07 Practice for Microetching Metals and AlloysE 691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test MethodE 1245 Practice for Determining the Inclusion or SecondPhase Constituent Content of Metals by Automatic ImageAnalysis3. Terminology3.1 DefinitionsFor definit
7、ions of terms used in this prac-tice, see Terminology E7.3.2 Definitions of Terms Specific to This Standard:3.2.1 point countthe total number of points in a test gridthat fall within the microstructural feature of interest, or on thefeature boundary; for the latter, each test point on the boundaryis
8、 one half a point.3.2.2 point fractionthe ratio, usually expressed as a per-centage, of the point count of the phase or constituent ofinterest on the two-dimensional image of an opaque specimento the number of grid points, which is averaged over n fields toproduce an unbiased estimate of the volume
9、fraction of thephase or constituent.3.2.3 stereologythe methods developed to obtain informa-tion about the three-dimensional characteristics of microstruc-tures based upon measurements made on two-dimensionalsections through a solid material or their projection on asurface.3.2.4 test grida transpare
10、nt sheet or eyepiece reticle witha regular pattern of lines or crosses that is superimposed overthe microstructural image for counting microstructural featuresof interest.3.2.5 volume fractionthe total volume of a phase orconstituent per unit volume of specimen, generally expressedas a percentage.3.
11、3 Symbols:PT= total number of points in the test grid.Pi= point count on the ithfield.PP(i) =PiPT3 100 = percentage of grid points, in theconstituent observed on the ithfield.n = number of fields counted.Pp= 1n(i 5 1nPpi! = arithmetic average of Pp(i).s = estimate of the standard deviation (s) (see
12、(Eq3) in Section 10).1This test method is under the jurisdiction of ASTM Committee E04 onMetallography and is the direct responsibility of Subcommittee E04.14 on Quanti-tative Metallography.Current edition approved Nov. 1, 2005. Published December 2005. Originallyapproved in 1976. Last previous edit
13、ion approved in 2002 as E 562 02.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM Internationa
14、l, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.95 % CI = 95 % confidence interval= 6ts/=n (see Note 1).t = a multiplier related to the number of fieldsexamined and used in conjunction with thestandard deviation of the measurements to de-termine the 95% CI.VV=
15、volume fraction of the constituent or phaseexpressed as a percentage (see (Eq 5) in Section10).% RA = % relative accuracy, a measure of the statisticalprecision = (95 % CI/ Pp) 3 100.NOTE 1 Table 1 gives the appropriate multiplying factors (t) for anynumber of fields measured.4. Summary of Test Meth
16、od4.1 Aclear plastic test grid or eyepiece reticle with a regulararray of test points is superimposed over the image, or aprojection of the image, produced by a light microscope,scanning electron microscope, or micrograph, and the numberof test points falling within the phase or constituent of inter
17、estare counted and divided by the total number of grid pointsyielding a point fraction, usually expressed as a percentage, forthat field. The average point fraction for n measured fieldsgives an estimate of the volume fraction of the constituent. Thismethod is applicable only to bulk opaque planar s
18、ectionsviewed with reflected light or electrons.5. Significance and Use5.1 This test method is based upon the stereological prin-ciple that a grid with a number of regularly arrayed points,when systematically placed over an image of a two-dimensional section through the microstructure, can provide,a
19、fter a representative number of placements on different fields,an unbiased statistical estimation of the volume fraction of anidentifiable constituent or phase (1, 2, 3).35.2 This test method has been described (4) as beingsuperior to other manual methods with regard to effort, bias,and simplicity.5
20、.3 Any number of clearly distinguishable constituents orphases within a microstructure (or macrostructure) can becounted using the method. Thus, the method can be applied toany type of solid material from which adequate two-dimensional sections can be prepared and observed.5.4 A condensed step-by-st
21、ep guide for using the method isgiven in Annex A1.6. Apparatus6.1 Test Grid, consisting of a specified number of equallyspaced points formed by the intersection of very thin lines. Twocommon types of grids (circular or square array) are shown inFig. 1.6.1.1 The test grid can be in the form of a tran
22、sparent sheetthat is superimposed upon the viewing screen for the measure-ment.6.1.2 Eyepiece Reticle, may be used to superimpose a testgrid upon the image.6.2 Light Microscope, or other suitable device with aviewing screen at least 100 mm 3 125 mm, preferably withgraduated x and y stage translation
23、 controls, should be used toimage the microstructure.6.3 Scanning Electron Microscope, may also be used toimage the microstructure; however, relief due to polishing orheavy etching must be minimized or bias will be introduced asa result of deviation from a true two-dimensional sectionthrough the mic
24、rostructure.6.4 Micrographs, of properly prepared opaque specimens,taken with any suitable imaging device, may be used providedthe fields are selected without bias and in sufficient quantity toproperly sample the microstructure.6.4.1 The applicable point counting grid shall only beapplied once to ea
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME5622005E1752STANDARDTESTMETHODFORDETERMININGVOLUMEFRACTIONBYSYSTEMATICMANUALPOINTCOUNTPDF

链接地址:http://www.mydoc123.com/p-533039.html