ASTM E549-1987(2014) 9618 Standard Guide for Preparing Field Sprayer Calibration Procedures《编制野外用喷雾器校准程序的标准指南》.pdf
《ASTM E549-1987(2014) 9618 Standard Guide for Preparing Field Sprayer Calibration Procedures《编制野外用喷雾器校准程序的标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM E549-1987(2014) 9618 Standard Guide for Preparing Field Sprayer Calibration Procedures《编制野外用喷雾器校准程序的标准指南》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E549 87 (Reapproved 2014)Standard Guide forPreparing Field Sprayer Calibration Procedures1This standard is issued under the fixed designation E549; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revis
2、ion. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide is for those who prepare field sprayercalibration procedures. The purpose is to encourage methodsthat will improve un
3、iformity, accuracy, and safety of pesticideapplication with field sprayers.1.2 The values stated in SI units are to be regarded asstandard. The values given in parentheses are mathematicalconversions to inch-pound units that are provided for informa-tion only and are not considered standard.1.3 This
4、 standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specific hazardsta
5、tements see Section 4.2. Significance and Use2.1 This guide provides information on the calibration ofboom-type field sprayers used for broadcast, band, or rowapplications. It is easily adapted to boomless and air-carriertype sprayers for broadcast applications and to rotary atomizerssuch as spinnin
6、g disks. A single calibration procedure that isapplicable in all situations is not feasible because of the natureof the variables involved in pesticide application. Electroniccontrollers and other aids should be calibrated by one of thesemethods.3. Apparatus3.1 Apparatus needed will depend on the me
7、thod of cali-bration. Common items include the following:3.1.1 Measuring DeviceTape of at least 25 m (50 ft) inlength, or other suitable measuring devices.3.1.2 Marking DevicesStakes or flags for marking ameasured course.3.1.3 Container, large enough to collect nozzle output for 30s, and graduated t
8、o allow accuracy within 1 %.3.1.4 Pressure Gage, accurate and of the proper range.3.1.5 Timing DeviceA watch with a sweep second hand,or a stop watch.4. Hazards4.1 A cautionary statement for the safe handling, storage,and disposal of agricultural chemicals shall be included withapplicator calibratio
9、n procedures.4.2 Use water alone to calibrate the sprayer unless the flowrate of the actual spray mixture varies more than 5 % from theflow rate of water. (See 5.1.1.2.)4.3 Calibration with Actual Spray Mixture:4.3.1 Wear suitable approved safety equipment and protec-tive clothing. Avoid contact wit
10、h the spray.4.3.2 Avoid contamination of the area. Collect all nozzleoutput. Calibrate only when the wind speed is below 8 km/h (5mph).5. Recommendations5.1 The volume of spray material applied to a given areadepends on three variables. Each variable must be determinedwhen developing a specific cali
11、bration procedure.5.1.1 Nozzle Flow RateThe nozzle flow rate varies withthe following:5.1.1.1 Nozzle CapacitySelect the orifice size that willbest fit the requirements of application, volume, pressure, andground speed.5.1.1.2 Nature of FluidIf the spray mixture will be alteredconsiderably by the add
12、ition of adjuvants, compare the flowrate of the mixture to that of water. If the rate difference is 5 %or more, use the actual spray mixture in the calibration.5.1.1.3 Fluid PressureA constant pressure should bemaintained to achieve uniform application. Flow rate is gen-erally proportional to the sq
13、uare root of the pressure dropacross the nozzle.5.1.2 Ground Speed of SprayerThis does not apply toground-driven pumps. This parameter has an inverse relation-ship to the spray volume. It is the easiest factor to change forminor corrections in the application rate. Ground speed shouldbe maintained u
14、niformly for uniform application, even whenground-driven pumps or electronic controllers are used.5.1.3 Sprayed Width per NozzleCalibration proceduresshould be used to determine the amount (in litres or gallons) ofliquid applied per unit area (hectare or acre) actually treated1This guide is under th
15、e jurisdiction of ASTM Committee E35 on Pesticides,Antimicrobials, and Alternative Control Agentsand is the direct responsibility ofSubcommittee E35.22 on Pesticide Formulations and Delivery Systems.Current edition approved Oct. 1, 2014. Published December 2014. Originallyapproved in 1975. Last prev
16、ious edition approved in 2008 as E549 87 (2008).DOI: 10.1520/E0549-87R12.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1with the agricultural chemical. For band application, the areatreated is the area in the band and not the area of
17、 croplandcovered. Some pesticide recommendations are based on thearea of cropland covered rather than the area actually sprayed.In these cases, the spray width used in the calibration should bebased on the row spacing and not on the band width. See Notein 7.1.6. Calibration6.1 Perform the following
18、basic steps for the calibration offield sprayers:6.1.1 Nozzle Tip Selection:6.1.1.1 Considering the label recommendations and fieldcondition, select a spray application rate pressure and anoperating speed.6.1.1.2 From the spray width, speed, and spray applicationrate, determine the nozzle output req
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME549198720149618STANDARDGUIDEFORPREPARINGFIELDSPRAYERCALIBRATIONPROCEDURES 编制 野外 喷雾器 校准 程序 标准 指南

链接地址:http://www.mydoc123.com/p-533019.html