ASTM E492-2004 Standard Test Method for Laboratory Measurement of Impact Sound Transmission Through Floor-Ceiling Assemblies Using the Tapping Machine《利用夯击机进行冲击声通过地板和天花板组件的实验室测量标准试.pdf
《ASTM E492-2004 Standard Test Method for Laboratory Measurement of Impact Sound Transmission Through Floor-Ceiling Assemblies Using the Tapping Machine《利用夯击机进行冲击声通过地板和天花板组件的实验室测量标准试.pdf》由会员分享,可在线阅读,更多相关《ASTM E492-2004 Standard Test Method for Laboratory Measurement of Impact Sound Transmission Through Floor-Ceiling Assemblies Using the Tapping Machine《利用夯击机进行冲击声通过地板和天花板组件的实验室测量标准试.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 492 04Standard Test Method forLaboratory Measurement of Impact Sound TransmissionThrough Floor-Ceiling Assemblies Using the TappingMachine1This standard is issued under the fixed designation E 492; the number immediately following the designation indicates the year oforiginal adoption
2、 or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.INTRODUCTIONThis test method is one of several for evaluating the sound insulating prop
3、erties of buildingelements. It is designed to measure the impact sound transmission performance of an isolatedfloor-ceiling assembly, in a controlled laboratory environment. Others in the set deal with fieldmeasurement of impact sound transmission through floor-ceiling assemblies, and the laboratory
4、 andfield methods of measuring airborne sound transmission loss of building partitions such as walls,floor-ceiling assemblies, doors, and other space-dividing elements.1. Scope1.1 This test method covers the laboratory measurement ofimpact sound transmission of floor-ceiling assemblies using astanda
5、rdized tapping machine. It is assumed that the testspecimen constitutes the primary sound transmission path intoa receiving room located directly below and that a diffusesound field exists in this room.1.2 Measurements may be conducted on floor-ceiling as-semblies of all kinds, including those with
6、floating-floor orsuspended ceiling elements, or both, and floor-ceiling assem-blies surfaced with any type of floor-surfacing or floor-covering materials.1.3 This test method prescribes a uniform procedure forreporting laboratory test data, that is, the normalized one-thirdoctave band sound pressure
7、 levels transmitted by the floor-ceiling assembly due to the tapping machine.1.4 This standard does not purport to address the safetyconcerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety andhealth practices and determine the a
8、pplicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C 634 Terminology Relating to Environmental AcousticsE 90 Test Method for Laboratory Measurement of AirborneSound Transmission Loss of Building Partitions and Ele-mentsE 548 Guide for General Criteria Used
9、for EvaluatingLaboratory Competence3E 717 Guide for the Preparation of the Accreditation Annexof Acoustical Test StandardsE 989 Classification for Determination of Impact InsulationClass (IIC)E 2235 Test Method for the Determination of Decay Ratesfor Use in Sound Insulation Test Methods2.2 ANSI Stan
10、dards:S1.11 Specification for Octave-Band and Fractional-Octave-Band Analog and Digital Filters4S1.26 Method for the Calculation of the Absorption ofSound by the Atmosphere42.3 ISO Standard:1This test method is under the jurisdiction of ASTM Committee E33 onEnvironmental Acoustics and is the direct
11、responsibility of Subcommittee E33.03 onSound Transmission.Current edition approved April 1, 2004. Published May 2004. Originallyapproved 1973. Last previous edition approved 1996 as E 492 90 (1996)e1.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Servi
12、ce at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn4Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036.1Copyright ASTM International, 100 Barr Har
13、bor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.ISO 140/6 AcousticsMeasurement of Sound Insulation inBuildings and of Building Elements Part 6: LaboratoryMeasurements of Impact Sound Insulation of Floors43. Terminology3.1 The acoustical terminology used in this method isconsi
14、stent with Terminology C 634 except for the followingspecial usages.3.2 Definitions of Terms Specific to This Standard:3.2.1 receiving rooma reverberant room below the floorspecimen under test in which the sound pressure levels due tothe tapping machine are measured.3.2.2 source roomthe room contain
15、ing the tapping ma-chine.4. Summary of Test Method4.1 A standard tapping machine is placed in operation on atest-floor specimen that forms a horizontal separation betweentwo rooms, one directly above the other. (See Section 6.) Thetransmitted impact sound characterized by the spectrum of thespace-ti
16、me average one-third octave band sound pressurelevels produced by the tapping machine is measured in thereceiving room below.4.2 Since the spectrum depends on the absorption of thereceiving room, the sound pressure levels are normalized to areference absorption for purposes of comparing results ob-t
17、ained in different receiving rooms that differ in absorption.5. Significance and Use5.1 The evaluation of the impact sound-insulating perfor-mance of a floor-ceiling assembly begins with the measure-ment of the sound pressure levels in the room below the testspecimen. The spectrum of the noise in th
18、e room below isdetermined by the following:5.1.1 The size and the mechanical properties of the floor-ceiling assembly, such as its construction, surface, mounting oredge restraints, stiffness, or internal damping,5.1.2 The acoustical response of the room below, and5.1.3 Inevitably, the characteristi
19、cs and placement of theobject or device producing the impacts and the nature or degreeof the actual impact itself.5.2 This test method is based on the use of a standardizedtapping machine of the type specified in 8.1.1 and placed inspecific positions on the floor. This machine produces acontinuous s
20、eries of uniform impacts at a uniform rate on a testfloor and generates in the receiving room broadband soundpressure levels sufficiently high to make accurate and repro-ducible measurements possible. The tapping machine itself,however, is not designed to simulate any one type of impact,such as prod
21、uced by male or female footsteps.NOTE 1Caution: Because of its portable design, the tapping machinedoes not simulate the weight of a human walker. Therefore, the creak orboom of a limber floor assembly caused by such footstep excitation maynot be reflected in the single number impact rating derived
22、from testresults obtained by this test method. The degree of correlation between theresults of tapping machine tests in the laboratory and the overall fieldperformance of floors under typical conditions of domestic impactexcitation may be subject to some variation, depending on both the typeof floor
23、 construction and the nature of the impact excitation.6. Test Rooms6.1 Flanking Transmission:6.1.1 The test rooms shall be so constructed and arrangedthat the test specimen constitutes the only important transmis-sion path between them. The impact sound pressure leveltransmitted through the test str
24、ucture shall be at least 10 dBgreater than that transmitted into the receiving room by allother paths.6.1.2 The limit of impact sound levels that can be measuredin the receiving room without being biased by flankingtransmission must be determined for each test facility. Asuggested method is to build
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME4922004STANDARDTESTMETHODFORLABORATORYMEASUREMENTOFIMPACTSOUNDTRANSMISSIONTHROUGHFLOORCEILINGASSEMBLIESUSINGTHETAPPINGMACHINE

链接地址:http://www.mydoc123.com/p-532876.html