ASTM E467-2008e1 1593 Standard Practice for Verification of Constant Amplitude Dynamic Forces in an Axial Fatigue Testing System《轴向疲劳试验系统的恒定振幅动力核查的标准操作规程》.pdf
《ASTM E467-2008e1 1593 Standard Practice for Verification of Constant Amplitude Dynamic Forces in an Axial Fatigue Testing System《轴向疲劳试验系统的恒定振幅动力核查的标准操作规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E467-2008e1 1593 Standard Practice for Verification of Constant Amplitude Dynamic Forces in an Axial Fatigue Testing System《轴向疲劳试验系统的恒定振幅动力核查的标准操作规程》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E467 081Standard Practice forVerification of Constant Amplitude Dynamic Forces in anAxial Fatigue Testing System1This standard is issued under the fixed designation E467; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision,
2、 the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTE3.2.1 and 3.2.15 were editorially revised in December 2011.1. Scope1.1 This practice covers procedures for the d
3、ynamic verifi-cation of cyclic force amplitude control or measurementaccuracy during constant amplitude testing in an axial fatiguetesting system. It is based on the premise that force verificationcan be done with the use of a strain gaged elastic element. Useof this practice gives assurance that th
4、e accuracies of forcesapplied by the machine or dynamic force readings from the testmachine, at the time of the test, after any user appliedcorrection factors, fall within the limits recommended inSection 9. It does not address static accuracy which must firstbe addressed using Practices E4 or equiv
5、alent.1.2 Verification is specific to a particular test machineconfiguration and specimen. This standard is recommended tobe used for each configuration of testing machine and speci-men. Where dynamic correction factors are to be applied to testmachine force readings in order to meet the accuracy re
6、com-mended in Section 9, the verification is also specific to thecorrection process used. Finally, if the correction process istriggered or performed by a person, or both, then the verifica-tion is specific to that individual as well.1.3 It is recognized that performance of a full verificationfor ea
7、ch configuration of testing machine and specimen con-figuration could be prohibitively time consuming and/or ex-pensive. Annex A1 provides methods for estimating the dy-namic accuracy impact of test machine and specimenconfiguration changes that may occur between full verifica-tions. Where test mach
8、ine dynamic accuracy is influenced by aperson, estimating the dynamic accuracy impact of all indi-viduals involved in the correction process is recommended.This practice does not specify how that assessment will bedone due to the strong dependence on owner/operators of thetest machine.1.4 This pract
9、ice is intended to be used periodically. Con-sistent results between verifications is expected. Failure toobtain consistent results between verifications using the samemachine configuration implies uncertain accuracy for dynamictests performed during that time period.1.5 This practice addresses the
10、accuracy of the testingmachines force control or indicated forces, or both, ascompared to a dynamometers indicated dynamic forces. Forcecontrol verification is only applicable for test systems that havesome form of indicated force peak/valley monitoring or am-plitude control. For the purposes of thi
11、s verification, thedynamometers indicated dynamic forces will be consideredthe true forces. Phase lag between dynamometer and forcetransducer indicated forces is not within the scope of thispractice.1.6 The results of either theAnnexA1 calculation or the fullexperimental verification must be reporte
12、d per Section 10 ofthis standard.1.7 This practice provides no assurance that the shape of theactual waveform conforms to the intended waveform withinany specified tolerance.1.8 This standard is principally focused at room temperatureoperation. It is believed there are additional issues that must be
13、addressed when testing at high temperatures. At the presenttime, this standard practice must be viewed as only a partialsolution for high temperature testing.1.9 The values stated in inch-pound units are to be regardedas standard. No other units of measurement are included in thisstandard.1.10 This
14、standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2
15、.1 ASTM Standards:2E4 Practices for Force Verification of Testing Machines1This practice is under the jurisdiction of ASTM Committee E08 on Fatigue andFracture and is the direct responsibility of Subcommittee E08.03 on AdvancedApparatus and Techniques.Current edition approved Nov. 1, 2008. Published
16、 January 2009. Originallyapproved in 1972. Last previous edition approved in 2004 as E467 98a (2004).DOI: 10.1520/E0467-08.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, re
17、fer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.E6 Terminology Relating to Methods of Mechanical TestingE1823 Terminology Relating to Fatigue and Fracture Test-ingE1942 Gu
18、ide for Evaluating Data Acquisition SystemsUsed in Cyclic Fatigue and Fracture Mechanics Testing2.2 Military Standard:31312-B Fastener Test Methods2.3 ANSI Standard:4Z540-1-1994 Calibration Laboratories and Measuring andTest EquipmentGeneral Requirements2.4 NCSL Standard:4Publication 940830/1600 NCS
19、L Glossary of MetrologyRelated Terms3. Terminology3.1 Terminology used in this practice is in accordance withTerminology E1823. Definitions provided in this practice areconsidered either unfamiliar or not included in TerminologyE1823.3.2 Definitions:3.2.1 accuracy, nThe quantitative difference betwe
20、en atest measurement and a reference value.3.2.2 amplitude, none-half the peak-to-peak measurementof the cyclic waveform.3.2.3 cal factor, nthe conversion factor between thedynamometer force and the indicated force.3.2.4 conditioned force, nthe high level voltage or digitaldata available from the dy
21、namometer or force transducerssignal conditioning instrumentation; it is frequently of valueduring dynamic verification as it can be more convenientlymonitored by stand alone measurement instrumentation.3.2.5 corrected force, nthe force obtained after applying adynamic correction factor to the force
22、 transducers indicatedforce.3.2.6 data acquisition equipment, nthe equipment used toconvert a conditioned force to an indicated force.3.2.7 dynamic dynamometer forces, nthe maximum andminimum forces produced in the dynamometer during aportion of a dynamic test.3.2.8 dynamic errors, nerrors in the fo
23、rce transducerscorrected force output that occur due to dynamic operation(with specimen bending errors intentionally corrected out).3.2.9 dynamic indicated forces, nthe maximum and mini-mum forces reported by the test machine during a portion of adynamic test. These values are typically obtained usi
24、ng anoscilloscope, peak-valley meter, or files generated by comput-erized data acquisition.3.2.10 dynamometer, nan elastic calibration device usedto indicate the forces applied by a fatigue testing system duringdynamic operation. A strain gaged specimen is often used asthe dynamometer. Suitable tran
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME4672008E11593STANDARDPRACTICEFORVERIFICATIONOFCONSTANTAMPLITUDEDYNAMICFORCESINANAXIALFATIGUETESTINGSYSTEM

链接地址:http://www.mydoc123.com/p-532833.html