ASTM F51 F51M-2000(2014)e1 Standard Test Method for Sizing and Counting Particulate Contaminant In and On Clean Room Garments《无菌室内衣服上颗粒污染物的粒度测量与计数的标准试验方法》.pdf
《ASTM F51 F51M-2000(2014)e1 Standard Test Method for Sizing and Counting Particulate Contaminant In and On Clean Room Garments《无菌室内衣服上颗粒污染物的粒度测量与计数的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F51 F51M-2000(2014)e1 Standard Test Method for Sizing and Counting Particulate Contaminant In and On Clean Room Garments《无菌室内衣服上颗粒污染物的粒度测量与计数的标准试验方法》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F51/F51M 00 (Reapproved 2014)1Standard Test Method forSizing and Counting Particulate Contaminant In and OnClean Room Garments1This standard is issued under the fixed designation F51/F51M; the number immediately following the designation indicates the year oforiginal adoption or, in the
2、 case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEEditorial changes were made throughout in March 2013.1. Scope1.1 This test method covers the d
3、etermination of detachableparticulate contaminant 5 m or larger, in and on the fabric ofclean room garments.1.2 This test method does not apply to nonporous fabricssuch as Tyvek (trademarked) or Gortex (trademarked). It onlyapplies to fabrics that are porous such as cotton or polyester.1.3 This test
4、 method provides not only the traditional opticalmicroscopic analysis but also a size distribution and surfaceobscuration analysis for particles on a fine-textured membranefilter or in a tape lift sample. It utilizes transmitted illuminationto render all particles darker than the background for gray
5、 leveldetection. Particles collected on opaque plates must be trans-ferred to a suitable membrane filter.1.4 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be
6、 used independently of the other. Combiningvalues from the two systems may result in non-conformancewith the standard.1.5 This standard may involve hazardous materials,operations, and equipment. This standard does not purport toaddress all of the safety concerns, if any, associated with itsuse. It i
7、s the responsibility of the user of this standard toestablish appropriate safety and health practices and deter-mine the applicability of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E1216 Practice for Sampling for Particulate Contaminationby Tape LiftF25/F25M Test
8、Method for Sizing and Counting AirborneParticulate Contamination in Cleanrooms and Other Dust-Controlled Areas2.2 Institute of Environmental Sciences and Technology(IEST) Document:3IEST-RP-CC003.2, Garment System Considerations forCleanrooms and Other Controlled Environments3. Terminology3.1 Definit
9、ions:3.1.1 fiber, nparticle longer than 100 m and with alength-to-width ratio exceeding 10:1.3.1.2 micrometre (m), nSI unit of length which is 10-6ofa metre or approximately 0.00004 in.3.1.3 particle size (L) (m)major projected dimension of aparticle.4. Summary of Test Method4.1 Filtered air is draw
10、n through five designated 0.01-m21.5-in.2or approximately 0.01-ft2 areas of a single thicknessof the garment fabric at a rate of 14 L/min 0.5 cfm for aperiod of 1 min for each area.4.2 The air drawn through the garment subsequently passesthrough a membrane filter disk, impinging the entrainedparticl
11、es upon the filter surface.4.3 The filter disk is then examined microscopically forparticles removed from the garment.4.4 For particles larger than 5 m, use optical analysis. Forparticles smaller than 5 m, use automated image analysis.4.5 Cleaning and counting techniques are in accordancewith those
12、established in Section 10.1This test method is under the jurisdiction of ASTM Committee E21 on SpaceSimulation andApplications of Space Technology and is the direct responsibility ofSubcommittee E21.05 on Contamination.Current edition approved Jan. 15, 2014. Published February 2014. Originallyapprov
13、ed in 1965. Last previous edition approved in 2007 as F51 - 00(2007)1. DOI:10.1520/F0051_F0051M-00R14E01.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standar
14、ds Document Summary page onthe ASTM website.3Available from Institute of Environmental Sciences and Technology (IEST),Arlington Place One, 2340 S. Arlington Heights Rd., Suite 100, Arlington Heights,IL 60005-4516, http:/www.iest.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, W
15、est Conshohocken, PA 19428-2959. United States15. Significance and Use5.1 The test method for particulate sizing and numbers ongarments is nondestructive and may be used to evaluate thecontamination levels of fibers and particles on and in cleanroom garments. The test may be used for evaluating thec
16、leanliness levels of new or newly cleaned garments. It alsomay be used to evaluate the extent of fiber and particulatecontamination on garments that have been worn, if necessary.For this application, it is necessary to sample representativeareas of the garment fabric.6. Apparatus6.1 Filter Assembly
17、and Adapter, see Fig. 1 and Fig. 2.6.1.1 Filter Holder, aerosol open type having an effectivefilter area of 960 6 25 mm2.6.2 Vacuum Pump or Aspirator, capable of operating at apressure of 7 kPa 500 torr with a flow rate of 14 L/min 0.5cfm.6.3 Flowmeter or Orifice, calibrated and having a capacityin
18、excess of 14 L/min 0.5 cfm, or a limiting orifice calibratedwith the pump, filter holder, and filter used for this test methodat a flow rate of 14 6 0.5 L/min 0.50 6 0.02 cfm. Ensure,visually, that the orifice is free of obstructing matter beforeeach test.6.4 Membrane Filters:6.4.1 Black, 0.80-m por
19、e size, 47-mm diameter with3.08-mm imprinted grid for fabric particles.6.4.2 White, 0.80-m pore size, 47-mm diameter withoutimprinted grid for fabric particles and automated image ana-lyzer.6.4.3 White, 5.0-m pore size, 47-mm diameter (air prefilterused with the filters in 6.4.1 and 6.4.2).6.4.4 Pla
20、stic Petri Slides with Covers ,4plastic petri dishes,60-mm diameter or glass microscope slides, 50 by 75 mm.6.5 Binocular Microscope with ocular-objective combina-tions to obtain 40 to 45 and 90 to 150 magnifications. Latterobjective shall have a numerical aperture of 0.15 min.6.6 Programmable Image
21、 Analyzer, a Computer-Driven Mi-croscope Which Counts and Sizes Particles With AutomatedStage and Automated Focus Interface:6.6.1 Microscope, with a large glass platform automaticstage and automated focus.6.6.2 Objectives and Projection Lenses, to generate a pixeldimension of about 5 m or less.6.7 F
22、orceps, with unserrated tips.6.8 Normal Counter, (2 gang) or equivalent. See Note 1.NOTE 1The Veeder Root counter has been found satisfactory for thispurpose.6.9 Microscope Lamp, 6 V, 5 A high intensity.6.10 Stage Micrometer, standard 0.01- to 0.1-mm scale.6.11 Ocular Micrometer Scale, 5-mm linear s
23、cale with 100divisions.6.12 Standard Counting Specimens.7. Sampling Requirements7.1 The sample shall be collected by drawing air filtered to5 m through the test garment, impinging the garment-borneparticles on the membrane filter. The filter surface mounted inthe open-type aerosol filter holder shal
24、l be placed on the outersurface of the test garment. The garment is firmly clamped tothe filter holder by means of the air-filter adapter. Duringsampling, the garment shall be hung or carefully positioned tominimize extraneous contamination.7.2 The standard sample of this test method is secured with
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF51F51M20002014E1STANDARDTESTMETHODFORSIZINGANDCOUNTINGPARTICULATECONTAMINANTINANDONCLEANROOMGARMENTS

链接地址:http://www.mydoc123.com/p-532644.html