《ASTM F319-2009 Standard Practice for Polarized Light Detection of Flaws in Aerospace Transparency Heating Elements《航空航天用透明加热元件中裂纹的偏振光检测标准实施规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM F319-2009 Standard Practice for Polarized Light Detection of Flaws in Aerospace Transparency Heating Elements《航空航天用透明加热元件中裂纹的偏振光检测标准实施规范》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 319 09Standard Practice forPolarized Light Detection of Flaws in AerospaceTransparency Heating Elements1This standard is issued under the fixed designation F 319; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the y
2、ear of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONElectrically conductive coatings used in aerospace transparencies for heating purposes may containflaws resulti
3、ng from imperfections of materials, imperfections of manufacturing techniques, handlingdamage, or contamination. Flaws may develop before, during, or after coating and processing andusually appear as hairline cracks, scratches, or pin holes. When these flaws are of sufficient size, hotspots can occu
4、r as a result of disruption and concentration of the flow of electrical current adjacent tothe flaws. These hot spots may result in reduced service life of the transparency. Hot spot flaws in thetransparency may also produce undesirable temporary distortion of vision during powered operationof the h
5、eater and permanent vision distortion after repeated cycling of the heater.Polarized light is widely used to detect electrically conductive coating flaws during aerospacetransparency processing.1. Scope1.1 This practice covers a standard procedure for detectingflaws in the conductive coating (heater
6、 element) by theobservation of polarized light patterns.1.2 This practice applies to coatings on surfaces of mono-lithic transparencies as well as to coatings imbedded inlaminated structures.1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement are included i
7、n thisstandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.
8、 For specificprecautionary statements see Section 6.2. Terminology2.1 Definitions:2.1.1 transparent conductive coatinga transparent thinfilm of electrically conductive material such as gold, stannousoxide, or indium oxide applied to plastic or glass which, whenbounded by connecting bus-bars energize
9、d by electricity,becomes a resistance type heating element.2.1.2 electrically conductive coating flawan electricaldiscontinuity in the coating, caused generally by coatingcracks, pin holes, fine threads, scratches, and so forth.3. Summary of Practice3.1 Flaws in electrically powered conductive coati
10、ngs pro-duce local concentrations of current, which result in tempera-ture gradients and stresses. Since glass and plastic transparen-cies are birefringent when stressed, flaws can be detected byoptical methods, and in this case by the use of polarized light.3.2 This practice consists of directing p
11、olarized lightthrough a heated transparent test specimen and reading thetransmitted light with a polarizing screen or filter. Diffractedlight from the region of the flaw will become visible, in theform of a brighter or more intense local image, usually shapedlike a butterfly.4. Significance and Use4
12、.1 This practice is useful as a screening basis for accep-tance or rejection of transparencies during manufacturing sothat units with identifiable flaws will not be carried to finalinspection for rejection at that time.4.2 This practice may also be employed as a go-no gotechnique for acceptance or r
13、ejection of the finished product.1This practice is under the jurisdiction of ASTM Committee F07 on Aerospaceand Aircraft and is the direct responsibility of Subcommittee F07.08 on TransparentEnclosures and Materials.Current edition approved May 15, 2009. Published June 2009. Originallyapproved in 19
14、77. Last previous edition approved in 2003 as F 319 91a (2003).1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.3 This practice is simple, inexpensive, and effective.Flaws identified by this practice, as with other optical methods,a
15、re limited to those that produce temperature gradients whenelectrically powered. Any other type of flaw, such as minorscratches parallel to the direction of electrical flow, are notdetectable.5. Apparatus5.1 The elements of the apparatus are detailed below in theirphysical relationship as shown in F
16、ig. 1. The minimum sizeand spacing of the elements of the apparatus are determined bythe size and curvature of the part. The size of light source, lightdiffuser, and polarizing screen shall be large enough so thatevery portion of the electrically coated area of the testspecimen is in the light path
17、and is uniformly back-lit. If thetest specimen is curved severely, its position may have to beadjusted during inspection so that the light path is within 20 ofnormal to the location being viewed. Since specimen size andcurvature vary considerably, a dimensionally fixed standard isnot given.5.2 The a
18、pparatus, in the order of assembly, consists of thefollowing:5.2.1 Uniform Light Source, such as a bank of fluorescentlamps.5.2.2 Translucent Light Diffusion Plate, such as milk-whiteglass located so as to provide a uniform light distribution.5.2.3 Polarizing Screen, which converts the diffused ligh
19、t topolarized light.5.2.4 Transparent Dust Shield (optional).5.2.5 Support for the specimen.5.2.6 Polarizing Viewer, hand-held or mounted so it can berotated to give maximum contrast as an analyzer.5.2.7 Electrical Power Supply, regulated.5.2.8 Timer, for controlling power application.FIG. 1 Typical
20、 Arrangement for Polarized Light MethodF3190925.2.9 Meters, for measuring power input to heater element.6. Safety Precautions6.1 This practice may require application of high voltages.Exercise precautions to prevent direct or indirect exposure oftest personnel to terminals, test leads, and so forth.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF3192009STANDARDPRACTICEFORPOLARIZEDLIGHTDETECTIONOFFLAWSINAEROSPACETRANSPARENCYHEATINGELEMENTS 航空航天

链接地址:http://www.mydoc123.com/p-532571.html