《ASTM F311-2008(2013) Standard Practice for Processing Aerospace Liquid Samples for Particulate Contamination Analysis Using Membrane Filters《用膜过滤器对颗粒污染物分析用航空航天液态试样进行处理的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM F311-2008(2013) Standard Practice for Processing Aerospace Liquid Samples for Particulate Contamination Analysis Using Membrane Filters《用膜过滤器对颗粒污染物分析用航空航天液态试样进行处理的标准实施规程》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F311 08 (Reapproved 2013)Standard Practice forProcessing Aerospace Liquid Samples for ParticulateContamination Analysis Using Membrane Filters1This standard is issued under the fixed designation F311; the number immediately following the designation indicates the year of originaladoptio
2、n or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A superscriptepsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the processing of liquids in prepa-ration for particul
3、ate contamination analysis using membranefilters and is limited only by the liquid-to-membrane filtercompatibility.1.2 The practice covers the procedure for filtering a mea-sured volume of liquid through a membrane filter. When thispractice is used, the particulate matter will be randomlydistributed
4、 on the filter surface for subsequent contaminationanalysis methods.1.3 The practice describes procedures to allow handlingparticles in the size range between 2 and 1000 m withminimum losses during handling.1.4 The values stated in SI units are to be regarded asstandard. No other units of measuremen
5、t are included in thisstandard.2. Referenced Documents2.1 ASTM Standards:2D287 Test Method for API Gravity of Crude Petroleum andPetroleum Products (Hydrometer Method)D1078 Test Method for Distillation Range of Volatile Or-ganic LiquidsD1193 Specification for Reagent WaterD1353 Test Method for Nonvo
6、latile Matter in Volatile Sol-vents for Use in Paint, Varnish, Lacquer, and RelatedProductsD1836 Specification for Commercial HexanesD2021 Specification for Neutral Detergent, 40 PercentAlky-lbenzene Sulfonate Type (Withdrawn 2000)3F302 Practice for Field Sampling of Aerospace Fluids inContainersF30
7、3 Practices for Sampling for Particles in AerospaceFluids and ComponentsF312 Test Methods for Microscopical Sizing and CountingParticles from Aerospace Fluids on Membrane Filters3. Definition3.1 filtered liquid dispenseras used in this practice, adispenser capable of delivering rinse liquid through
8、a filter withpore size no larger than half the size of the smallest particlebeing considered for measurement.4. Significance and Use4.1 This practice provides for the processing of liquidsamples obtained in accordance with Practice F302 and Prac-tices F303. It will provide the optimum sample process
9、ing forvisual contamination methods such as Method F312, and TestMethod F314.5. Apparatus and Materials5.1 Filtration FunnelThe funnel opening in contact withthe membrane shall be approximately 35.0 mm in insidediameter. The effective area shall be calibrated. If the funnel isto be used for measurin
10、g the sample volume, the funnel shallbe calibrated within 62 % of the required volume.5.2 Membrane Filter SupportEither a fritted-glass,sintered-metal, polyphenyl-sulfone or stainless steel screenmay be used. The support shall be so designed as to enableattachment to a vacuum flask.5.3 Vacuum Flask.
11、5.4 Funnel-Holding DeviceA provision should be madefor the dissipation of static electricity from the funnel.5.5 A clean bench or hood, supplied with unidirectionalflow filtered air, in which uncovered components may beplaced.5.6 Vacuum SourceMinimum vacuum gage reading of 61kPa (or other metric uni
12、ts acceptable to ASTM).5.7 Forceps, unserrated tips.5.8 Filtered Liquid Dispenser.1This practice is under the jurisdiction of ASTM Committee E21 on SpaceSimulation and Applications of Space Technology and is the direct responsibility ofSubcommittee E21.05 on Contamination.Current edition approved No
13、v. 1, 2013. Published November 2013. Originallyapproved in 1969. Last previous edition approved in 2008 as F311 08. DOI:10.1520/F0311-13.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume i
14、nformation, refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15.9 Membrane Filter, pore
15、size no greater than half the sizeof the smallest particle being considered for measurement. Thefilter shall have an imprinted grid on 3.10 6 0.02-mm centers.The color shall be chosen to provide maximum contrast withthe particulate contamination to be observed.NOTE 1When testing military hydraulic f
16、luids, a white cellulosemembrane of 0.45-m pore size, capable of filtering 80 mL of distilledwater per square centimeter per minute at 93 kPa (or other metric unitsacceptable to ASTM) and 25C is required.5.10 Petri Dishes, glass. Plastic Petri dishes may be usedonly if the selected plastic is known
17、to be compatible with thefiltered liquid.5.11 Glass Bottles, small-mouth, screw-capped, perma-nently marked to indicate sample volume.5.12 Plastic Film, 0.002-in. (0.05-mm) minimum thickness.5.13 Contrasting Pigment Suspension, to be used in calibra-tion of the funnel.5.14 Slides, glass, 50 by 50-mm
18、.5.15 Tape, transparent, pressure-sensitive.6. Reagents and Materials6.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemi
19、cal Society,where such specifications are available.4Other grades may beused, provided it is first ascertained that the reagent is ofsufficiently high purity to permit its use without lessening theaccuracy of the determination.6.2 Purity of WaterUnless otherwise indicated, referencesto water shall b
20、e understood to mean reagent water conformingto Specification D1193, Type III or clearer.6.3 Detergent, free-rinsing. Material conforming to Specifi-cation D2021 is suitable.6.4 Isopropyl Alcohol, acetone-free.56.5 Solvent, conforming to the following requirements(Note 2):6.5.1 Distillation Range, i
21、nitial boiling point 27C (80F)min; dry point 71C (160F) max, as determined in accordancewith Test Method D1078.6.5.2 API Gravity, 70 deg min, as determined in accordancewith Test Method D287.6.5.3 Residue, 0.004 g/100 mL max, as determined inaccordance with Method D1353.NOTE 2Commercial hexanes conf
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF31120082013STANDARDPRACTICEFORPROCESSINGAEROSPACELIQUIDSAMPLESFORPARTICULATECONTAMINATIONANALYSISUSINGMEMBRANEFILTERS

链接地址:http://www.mydoc123.com/p-532564.html