ASTM F311-1997(2002) Standard Practice for Processing Aerospace Liquid Samples for Particulate Contamination Analysis Using Membrane Filters《用膜滤器进行粒状污染物分析用航空航天流体样品的处理》.pdf
《ASTM F311-1997(2002) Standard Practice for Processing Aerospace Liquid Samples for Particulate Contamination Analysis Using Membrane Filters《用膜滤器进行粒状污染物分析用航空航天流体样品的处理》.pdf》由会员分享,可在线阅读,更多相关《ASTM F311-1997(2002) Standard Practice for Processing Aerospace Liquid Samples for Particulate Contamination Analysis Using Membrane Filters《用膜滤器进行粒状污染物分析用航空航天流体样品的处理》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 311 97 (Reapproved 2002)Standard Practice forProcessing Aerospace Liquid Samples for ParticulateContamination Analysis Using Membrane Filters1This standard is issued under the fixed designation F 311; the number immediately following the designation indicates the year oforiginal adopt
2、ion or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the processing of liquids in prepa-ration for parti
3、culate contamination analysis using membranefilters and is limited only by the liquid-to-membrane filtercompatibility.1.2 The practice covers the procedure for filtering a mea-sured volume of liquid through a membrane filter. When thispractice is used, the particulate matter will be randomlydistribu
4、ted on the filter surface for subsequent contaminationanalysis methods.1.3 The practice describes procedures to allow handlingparticles in the size range between 2 and 50 m with minimumlosses during handling.2. Referenced Documents2.1 ASTM Standards:D 287 Test Method forAPI Gravity of Crude Petroleu
5、m andPetroleum Products (Hydrometer Method)2D 1078 Test Method for Distillation Range of VolatileOrganic Liquids3D 1193 Specification for Reagent Water4D 1353 Test Method for Nonvolatile Matter in VolatileSolvents for Use in Paint, Varnish, Lacquer, and RelatedProducts3D 1836 Specification for Comme
6、rcial Hexanes3D 2021 Specification for Neutral Detergent, 40 PercentAlkylbenzene Sulfonate Type5F 302 Practice for Field Sampling of Aerospace Fluids inContainers6F 303 Practices for Sampling Aerospace Fluids from Com-ponents6F 312 Methods for Microscopical Sizing and CountingParticles from Aerospac
7、e Fluids on Membrane Filters73. Terminology Definition3.1 filtered liquid dispenseras used in this practice, adispenser capable of delivering rinse liquid through a filter withpore size no larger than half the size of the smallest particlebeing considered for measurement.4. Significance and Use4.1 T
8、his practice provides for the processing of liquidsamples obtained in accordance with Practice F 302 andPractices F 303. It will provide the optimum sample processingfor visual contamination methods such as Method F 312, andTest Method F 314.5. Apparatus and Materials5.1 Filtration FunnelThe funnel
9、opening in contact withthe membrane shall be approximately 35.0 mm in insidediameter. The effective area shall be calibrated. If the funnel isto be used for measuring the sample volume, the funnel shallbe calibrated within 62 % of the required volume.5.2 Membrane Filter SupportEither a fritted-glass
10、,sintered-metal, or stainless steel screen may be used. Thesupport shall be so designed as to enable attachment to avacuum flask.5.3 Vacuum Flask.5.4 Funnel-Holding DeviceA provision should be madefor the dissipation of static electricity from the funnel.5.5 A clean bench or hood, supplied with unid
11、irectionalflow filtered air, in which uncovered components may beplaced.5.6 Vacuum SourceMinimum vacuum gage reading of 61kPa (or other metric units acceptable to ASTM).5.7 Forceps, unserrated tips.5.8 Filtered Liquid Dispenser.5.9 Membrane Filter, pore size no greater than half the sizeof the small
12、est particle being considered for measurement. Thefilter shall have an imprinted grid on 3.10 6 0.02-mm centers.1This practice is under the jurisdiction of ASTM Committee E21 on SpaceSimulation andApplication of Space Technologies and is the direct responsibility ofSubcommittee E21.05 on Contaminati
13、on.Current edition approved April 10, 1997. Published February 1998. Originallypublished as D 2391 69. Redesignated F 311 in 1970. Last previous editionF 311 78 (1992).2Annual Book of ASTM Standards, Vol 05.01.3Annual Book of ASTM Standards, Vol 06.04.4Annual Book of ASTM Standards, Vol 11.01.5Annua
14、l Book of ASTM Standards, Vol 15.04.6Annual Book of ASTM Standards, Vol 10.05.7Annual Book of ASTM Standards, Vol 14.02.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.The color shall be chosen to provide maximum contrast withthe par
15、ticulate contamination to be observed.NOTE 1When testing military hydraulic fluids, a white cellulosemembrane of 0.45-m pore size, capable of filtering 80 mL of distilledwater per square centimeter per minute at 93 kPa (or other metric unitsacceptable to ASTM) and 25C is required.5.10 Petri Dishes,
16、glass. Plastic Petri dishes may be usedonly if the selected plastic is known to be compatible with thefiltered liquid.5.11 Glass Bottles, small-mouth, screw-capped, perma-nently marked to indicate sample volume.5.12 Plastic Film, 0.002-in. (0.05-mm) minimum thickness.5.13 Contrasting Pigment Suspens
17、ion, to be used in calibra-tion of the funnel.5.14 Slides, glass, 50 by 50-mm.5.15 Tape, transparent, pressure-sensitive.6. Reagents and Materials6.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents shall conform to the
18、specifications of the Commit-tee on Analytical Reagents of the American Chemical Society,where such specifications are available.8Other grades may beused, provided it is first ascertained that the reagent is ofsufficiently high purity to permit its use without lessening theaccuracy of the determinat
19、ion.6.2 Purity of WaterUnless otherwise indicated, referencesto water shall be understood to mean reagent water conformingto Specification D 1193, Type III or clearer.6.3 Detergent, free-rinsing. Material conforming to Specifi-cation D 2021 is suitable.6.4 Isopropyl Alcohol, acetone-free.96.5 Solven
20、t, conforming to the following requirements(Note 2):6.5.1 Distillation Range, initial boiling point 27C (80F)min; dry point 71C (160F) max, as determined in accordancewith Test Method D 1078.6.5.2 API Gravity, 70 deg min, as determined in accordancewith Test Method D 287.6.5.3 Residue, 0.004 g/100 m
21、L max, as determined inaccordance with Method D 1353.NOTE 2Commercial hexanes conforming to Specification D 1836meet this requirement. Other chlorinated solvents, conforming to theMontreal conference on control of chlorinated fluorocarbons may besubstituted where solvent presents a safety hazard, pr
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF31119972002STANDARDPRACTICEFORPROCESSINGAEROSPACELIQUIDSAMPLESFORPARTICULATECONTAMINATIONANALYSISUSINGMEMBRANEFILTERS

链接地址:http://www.mydoc123.com/p-532562.html