ASTM F307-2013 Standard Practice for Sampling Pressurized Gas for Gas Analysis《气体分析用压缩气体取样的标准实施规程》.pdf
《ASTM F307-2013 Standard Practice for Sampling Pressurized Gas for Gas Analysis《气体分析用压缩气体取样的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM F307-2013 Standard Practice for Sampling Pressurized Gas for Gas Analysis《气体分析用压缩气体取样的标准实施规程》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F307 13Standard Practice forSampling Pressurized Gas for Gas Analysis1This standard is issued under the fixed designation F307; the number immediately following the designation indicates the year of originaladoption or, in the case of revision, the year of last revision. A number in par
2、entheses indicates the year of last reapproval. A superscriptepsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This practice describes procedures for obtaining asample of pressur
3、ized gas for gas analysis from a system orcomponent.1.2 The values stated in SI units are to be regarded as thestandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-pr
4、iate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For hazardstatement, see Section 6.2. Referenced Documents2.1 ASTM Standards:2F310 Practice for Sampling Cryogenic Aerospace FluidsG93 Practice for Cleaning Methods and Cleanliness Levelsfor Mat
5、erial and Equipment Used in Oxygen-EnrichedEnvironments3. Terminology3.1 Definitions:3.1.1 sample portthe designated point in a system orcomponent from which a representative gas sample may betaken.4. Summary of Practice4.1 Evacuated Sample Vessel ProcedureA sample pres-sure vessel is evacuated and
6、sealed with a minimum vacuumpressure of 10-3torr. The vessel is then attached to thedesignated pressurized sample port. The pressurized gas isallowed to enter the sample vessel until the pressure is equal tothe pressure of the system or component. The pressure issecured and the sample vessel assigne
7、d for appropriate analy-sis.4.2 Purged Sample Vessel ProcedureThe pressurized gassample port is opened to establish a low level purge. A samplevessel with valves opened at each end is attached to thepressurized sample port. The pressurized sample port is openedand the purge pressure is increased to
8、completely purge thevessel prior to sample capture. The vessel valves and sampleport valves are then closed and the sample vessel delivered foranalysis.5. ApparatusNOTE 1All apparatus used in the sample taking should be verified ascleaned and packaged within the requirements of the allowable contami
9、-nation of the system.5.1 Connecting Lines, rigid or flexible, pressure rated andidentified within recognized safety codes.5.2 Miscellaneous Fittings, as needed for sampling pointadaption.5.3 Tie-downs, suitable for sample line restraint in accordwith pressure, temperature, and recognized safety cod
10、es.5.4 Gas Sample Vessel, rated for the appropriate maximumand minimum pressure for the gas analysis method to be used.This vessel should have valves at inlet and outlet to enablelockup of vacuum or pressure. (See Fig. 1.)NOTE 2The gas sample vessel capacity is selected in accord withdesired sample
11、volume. For evacuated vessel sampling, a recommended8-L (500-in3) volume has been determined adequate to aerospace industry.Evacuated sample vessels should be helium leak tested prior to use.6. Safety Hazards6.1 Personnel must stand clear of exiting gas.6.2 Ear protection must be used when gas flow
12、approachessonic velocity.6.3 All lines and associated equipment must be connectedand operated within the requirements of recognized safetycodes.1This practice is under the jurisdiction of ASTM Committee E21 on SpaceSimulation and Applications of Space Technology and is the direct responsibility ofSu
13、bcommittee E21.05 on Contamination. ASTM Committee D02 on PetroleumProducts and Lubricants maintains a continued interest in this practice and willmake use of it in the future.Current edition approved June 1, 2013. Published July 2013. Originally approvedin 1966. Last previous edition approved in 20
14、07 as F307 02(2007). DOI:10.1520/F0307-13.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM Inte
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF3072013STANDARDPRACTICEFORSAMPLINGPRESSURIZEDGASFORGASANALYSIS 气体 分析 压缩 取样 标准 实施 规程 PDF

链接地址:http://www.mydoc123.com/p-532552.html