1、Designation: E3169 18Standard Guide forDigital Imaging and Communication in NondestructiveEvaluation (DICONDE)1This standard is issued under the fixed designation E3169; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of l
2、ast revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 The display, transfer and storage of digital nondestruc-tive evaluation data in a common, open format is necessary fort
3、he effective interpretation and preservation of evaluationresults. ASTM International has developed common openstandards for Digital Imaging and Communication in Nonde-structive Evaluation (DICONDE) based on the ubiquitoushealthcare industry standard Digital Imaging and Communica-tion in Medicine (D
4、ICOM). This guide provides an overviewof the ASTM International standard practices that addressDICONDE and assistance in identifying the correct standardpractices for different use cases.1.2 This document provides an overview of how to utilizethe ASTM DICONDE standard practices found in paragraph2.1
5、.2 on ASTM DICONDE Test Methods Standards for thedisplay, transfer and storage of digital nondestructive test data1.3 This document provides an overview of how to utilizethe DICOM standard found in paragraph 2.2 on Other Docu-ments for the display, transfer and storage of digital nonde-structive tes
6、t data for test methods not explicitly addressed bya DICONDE standard practice but having an equivalentmedical imaging modality.1.4 This document provides recommendations for thedisplay, transfer and storage of nondestructive digital test datanot addressed in 1.2 or 1.3.1.5 This document provides an
7、 overview of how to utilizethe ASTM DICONDE standard practices found in paragraph2.1.3 on ASTM DICONDE Interoperability Standards forvalidating a system that follows the ASTM DICONDE stan-dard for the display, transfer and storage of digital nondestruc-tive test data.1.6 This document provides an ov
8、erview of how to utilizethe ASTM DICONDE standard practices found in 2.1.3 forvalidating that two or more systems that follow the ASTMDICONDE standard for the transfer of digital nondestructivetest data can successfully transfer data.1.7 This document provides an overview of how to utilizethe ASTM D
9、ICONDE standard practices found in 2.1.3 forvalidating that two or more systems that follow the ASTMDICONDE standard for the display of digital nondestructivetest data display data consistently.1.8 Although this guide contains no values that requireunits, it does describe methods to store and commun
10、icate datathat do require units to be properly interpreted. The SI unitsrequired by this guide are to be regarded as standard. No otherunits of measurement are included in this guide.1.9 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is there
11、sponsibility of the user of this standard to establish appro-priate safety, health, and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.10 This international standard was developed in accor-dance with internationally recognized principles on standard
12、-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:22.1.1 General ASTM Standards:E1316 Terminology fo
13、r Nondestructive Examinations2.1.2 ASTM DICONDE Test Method Standards:E2339 Practice for Digital Imaging and Communication inNondestructive Evaluation (DICONDE)E2663 Practice for Digital Imaging and Communication inNondestructive Evaluation (DICONDE) for UltrasonicTest MethodsE2699 Practice for Digi
14、tal Imaging and Communication inNondestructive Evaluation (DICONDE) for Digital Ra-diographic (DR) Test Methods1This test method is under the jurisdiction of ASTM Committee E07 onNondestructive Testing and is the direct responsibility of Subcommittee E07.11 onDigital Imaging and Communication in Non
15、destructive Evaluation (DICONDE).Current edition approved June 15, 2018. Published August 2018. DOI: 10.1520/E3169-18.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer t
16、o the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established
17、in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.1E2738 Practice for Digital Imaging and CommunicationNondestructive Evaluation (DICONDE) for ComputedRadiography
18、(CR) Test MethodsE2767 Practice for Digital Imaging and Communication inNondestructive Evaluation (DICONDE) for X-ray Com-puted Tomography (CT) Test MethodsE2934 Practice for Digital Imaging and Communication inNondestructive Evaluation (DICONDE) for Eddy Current(EC) Test Methods2.1.3 ASTM DICONDE I
19、nteroperability Standards:E3147 Practice for Evaluating DICONDE Interoperability ofNondestructive Testing and Inspection Systems2.2 Other Documentation:3NEMA Standards Publication PS3, Version 3: Digital Imag-ing and Communications in Medicine (DICOM)ACR-NEMA 300-1998 Digital Imaging and Communica-t
20、ions in Medicine3. Terminology3.1 Definitions:3.1.1 Nondestructive evaluation terms used in this practicecan be found in Terminology E1316.3.1.2 DICONDE terms used in this practice can be found inTerminology E2339 and E3147.4. Summary of Guide4.1 DICOM provides rich methods for managing thedisplay,
21、transfer and storage of a wide variety of digital testdata. An explicit list of the digital data covered can be found inthe DICOM standard. These modalities are referred to asStandard SOP Classes.4.2 DICOM provides the flexibility to address the storage ofdigital data not expressly defined in a Stan
22、dard SOP Class.4.2.1 Standard Extended SOP Classes extend Standard SOPClasses with additional data that is user optional. Use of aStandard Extended SOP Class does not impact the interoper-ability of the SOP Class.4.2.2 Specialized SOP Classes are derived from StandardSOP Class but include changes to
23、 the mandatory data associ-ated with the SOP Class. Use of a Specialized SOP Class doesimpact interoperability and requires updates to the DICOM andDICONDE standards to ensure interoperability.4.3 The DICONDE standard is comprised of both StandardExtended and Specialized SOP Classes.4.3.1 Standard E
24、xtended SOP Classes are utilized whenthere is a medical imaging modality that closely aligns with anondestructive test method. Examples of this are E2663DICONDE for Ultrasonic Test Methods and E2699 DICONDEfor Digital Radiographic Test Methods. The DICONDE stan-dard practices that utilize Standard E
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME31692018STANDARDGUIDEFORDIGITALIMAGINGANDCOMMUNICATIONINNONDESTRUCTIVEEVALUATIONDICONDEPDF

链接地址:http://www.mydoc123.com/p-532391.html