《ASTM E3070-2016 Standard Test Method for Shear Thinning Index on Non-Newtonian Liquids Using a Concentric Cylinder Rotational Viscometer《使用同心圆筒旋转粘度计测定非牛顿液体剪切变稀指数的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E3070-2016 Standard Test Method for Shear Thinning Index on Non-Newtonian Liquids Using a Concentric Cylinder Rotational Viscometer《使用同心圆筒旋转粘度计测定非牛顿液体剪切变稀指数的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E3070 16Standard Test Method forShear Thinning Index on Non-Newtonian Liquids Using aConcentric Cylinder Rotational Viscometer1This standard is issued under the fixed designation E3070; the number immediately following the designation indicates the year oforiginal adoption or, in the ca
2、se of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method describes the determination of theshear thinning index of a shear-rate de
3、pendent (non-Newtonian) fluid using a cylindrical rotational viscometer. Avalue of the shear thinning index of unity indicates that thematerial is Newtonian in behavior. A value greater than unityindicates shear thinning behavior.1.2 The values stated in SI units are to be regarded asstandard. No ot
4、her units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility
5、of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E473 Terminology Relating to Thermal Analysis and Rhe-ologyE1142 Terminology Relating to Thermophysical PropertiesE2975 Test Method for Calibration of Concentric CylinderRotational Viscometers3. Terminology3.1 Definiti
6、onsSpecific technical terms used in this stan-dard method are described in Terminologies E473 and E1142including Celsius, non-Newtonian, rheometery, viscosity, andviscometer.3.2 Definitions of Terms Specific to This Standard:3.2.1 shear thinning, na decrease in viscosity with in-creasing shear rate,
7、 followed by a gradual recovery when thestress or shear rate is reduced to zero.3.2.2 shear thinning index, nthe ratio of apparent viscos-ity at two rotational speeds or shear rates.4. Summary of Test Method4.1 For Newtonian fluids, viscosity is a linear function ofshear rate. Non-Newtonian fluids a
8、re those for which theviscosity changes as a function of shear rate. Many materials ofinterest are non-Newtonian in behavior.4.2 The viscosity of a non-Newtonian fluid is measured atdifferent shear rates and the values compared as their ratio.This is known as the shear thinning index. For Newtonianf
9、luids the shear thinning ratio is unity. For non-Newtonianfluids the shear thinning ratio increases with increasing non-Newtonian nature.4.3 The shear thinning index of non-Newtonian fluids isdetermined by the ratio of viscosity measurements made at tworotational speeds, preferably a decade apart.5.
10、 Significance and Use5.1 The flow behavior of many fluids of interest is non-Newtonian in nature. Non-Newtonian behavior is best studiedusing rheometry apparatus. Nonetheless, estimations on non-Newtonian behavior may be made by recording viscosity atdiffering rotational speeds (or shear rates) usin
11、g rotationalviscometers.5.2 The shear thinning index provides a tool for the estima-tion of the amount of non-Newtonian behavior.5.3 The shear thinning index may be used in qualityassessment, trouble shooting, specification acceptance, andresearch.6. Apparatus6.1 Rotational ViscometerThe essential i
12、nstrumentationrequired providing the minimum rotational viscometer analyti-cal capabilities include:6.1.1 A drive motor, to apply a unidirectional rotationaldisplacement to the specimen at 5 or more rates of between 0.2r/min and 100 r/min constant to within 61%.6.1.2 A force sensor to measure the to
13、rque developed by thespecimen to with 61%.1This test method is under the jurisdiction ofASTM Committee E37 on ThermalMeasurements and is the direct responsibility of Subcommittee E37.08 on Rheol-ogy.Current edition approved Nov. 1, 2016. Published November 2016. DOI:10.1520/E3070-16.2For referenced
14、ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Consho
15、hocken, PA 19428-2959. United States16.1.3 A coupling shaft or other means to transmit therotational displacement from the motor to the rotational ele-ment.6.1.4 A spindle, geometry, tool, or rotational element to fixthe specimen between the coupling shaft and a stationaryposition.6.1.5 A specimen c
16、ontainer with the capacity to contain thetest specimen during testing.NOTE 1The size of the container used is determined by the size anddesign of the rotational element used. The container used may be specifiedby mutual agreement among the parties involved. In the absence of otherinformation, a low
17、form Griffin beaker of 600 mL capacity shall be used.6.1.6 A temperature sensor to provide an indication of thespecimen temperature over the range of 19C to 26C to within60.1C.NOTE 2Other temperature ranges may be used but shall be reported.6.1.7 A data collection device, to provide a means ofacquir
18、ing, storing, and displaying measured or calculatedsignals, or both. The minimum output signals required forrotational viscosity are torque, rotational speed, temperature,and time.NOTE 3Manual acquiring, storing, and displaying of measured orcalculated signals is permitted.6.1.8 A stand, to support,
19、 level, and raise the drive motor,shaft, and spindle.6.1.9 Auxiliary instrumentation considered useful in con-ducting this test method includes:6.1.9.1 Data analysis capability to provide viscosity, stress,or other useful quantities derived from measured signals.6.1.9.2 A level to indicate the verti
20、cal plumb of the drivemotor, shaft, and spindle.6.1.9.3 A guard to protect the spindle from mechanicaldamage.6.2 A temperature bath to provide a controlled isothermaltemperature environment for the specimen to within 60.01Cover the temperature range of 19C to 26C.NOTE 4Other temperatures may be used
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME30702016STANDARDTESTMETHODFORSHEARTHINNINGINDEXONNONNEWTONIANLIQUIDSUSINGACONCENTRICCYLINDERROTATIONALVISCOMETER

链接地址:http://www.mydoc123.com/p-532310.html