ASTM E2933-2013 Standard Specification for Stationary Point Chemical Vapor Detectors (SPCVD) for Homeland Security Applications《国土安全应用固定点化学蒸气探测器(SPCVD)的标准规范》.pdf
《ASTM E2933-2013 Standard Specification for Stationary Point Chemical Vapor Detectors (SPCVD) for Homeland Security Applications《国土安全应用固定点化学蒸气探测器(SPCVD)的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2933-2013 Standard Specification for Stationary Point Chemical Vapor Detectors (SPCVD) for Homeland Security Applications《国土安全应用固定点化学蒸气探测器(SPCVD)的标准规范》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2933 13Standard Specification forStationary Point Chemical Vapor Detectors (SPCVD) forHomeland Security Applications1This standard is issued under the fixed designation E2933; the number immediately following the designation indicates the year oforiginal adoption or, in the case of rev
2、ision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 General:1.1.1 This specification presents baseline performance re-quirements and additional optiona
3、l capabilities for stationarypoint chemical vapor detectors (SPCVD) designed forcontinuous, 24 hours a day 7 days a week, monitoring ofpublic, non-industrial facilities. This specification is one ofseveral that describe chemical vapor detectors (for example,handheld and stationary) and chemical dete
4、ction capabilitiesincluding: chemical vapor hazard detection, identification, andquantification.An SPCVD is capable of detecting and alarmingwhen exposed to chemical vapors that pose a risk as defined bythe Acute Exposure Guideline Levels for Selected AirborneChemicals (AEGL). For example, chemical
5、vapors of interestfor homeland security applications, see Appendix X1. TheSPCVD should not alarm to background chemical vapors andshould provide low false positive alarm rates and no falsenegatives. Procurement agents and end users must identify thespecific chemicals of interest and environmental re
6、quirementsfor the given facility.1.1.1.1 An SPCVD samples air from immediate surround-ings and is comprised of one or more detectors using one ormore chemical detection technologies. An SPCVD also in-cludes air sampling system(s), power system(s), computer(s),data storage, data network communication
7、 interface(s), and anenclosure, see Fig. 1. An SPCVD may be combined with otherSPCVDs, other chemical, biological, radiological, nuclear, andexplosive (CBRNE) detectors, and other monitoring devicessuch as video. A remote command center may monitor andcontrol these devices and communicate informatio
8、n to theresponsible authorities and responders, as depicted in Fig. 2.1.1.2 This specification provides the SPCVD baselinerequirements, including performance, system, environmental,and documentation requirements. This specification providesSPCVD designers, manufacturers, integrators, procurementpers
9、onnel, end users/practitioners, and responsible authorities acommon set of parameters to match capabilities and userneeds.1.1.3 This specification is not meant to provide for all uses.Manufacturers, purchasers, and end users will need to deter-mine specific requirements based on the installation loc
10、ationand environment.1.2 SPCVD Chemical Detection CapabilitiesManufacturers document and verify, through testing, thechemical detection capabilities of the SPCVD. Test methodsfor assessing chemical detection capabilities are available fromthe Department of Homeland Security and the Department ofDefe
11、nse and are listed in Appendix X2.1.3 SPCVD System and Environmental PropertiesManufacturers document and verify, through testing, the sys-tem and environmental properties of the SPCVD. Example testmethods for assessing the system and environmental propertiesare listed in Appendix X3.1.4 UnitsThe va
12、lues stated in SI units are to be regardedas standard. Vapor concentrations of the hazardous materialsare presented in parts per million (ppm) as used in AcuteExposure Guideline Levels for Selected Airborne Chemicals,Vols 1-9 (see 2.2) and in mg/m3.1.5 This standard does not purport to address all o
13、f thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E2885 Specification for
14、 Handheld Point Chemical VaporDetectors (HPCVD) for Homeland Security Applications1This specification is under the jurisdiction of ASTM Committee E54 onHomeland Security Applications and is the direct responsibility of SubcommitteeE54.01 on CBRNE Sensors and Detectors.Current edition approved July 1
15、, 2013. Published July 2013. DOI: 10.1520/E2933-13.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright
16、ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States12.2 U.S. Environmental Protection Agency3Acute Exposure Guideline Levels for Selected AirborneChemicals, Vols 19.2.3 U.S. Department of Homeland Security4Chemical Detection Performance Specificati
17、ons for MassTransit and Passenger Rail SystemsNational Information Exchange Model (NIEM), http:/www.niem.gov/.2.4 National Institute of Standards and Technology (NIST)5Publication 1402 Security Requirements for CryptographicModules2.5 Code of Federal Regulations6CFR, Title 40 Protection of the Envir
18、onment, Part 72.2Permits Regulation, Definitions.CFR, Title 10 NRC Regulations, Part 30.20, Gas and Aero-sol Detectors Containing Byproduct MaterialCFR Title 47 Telecommunication, Part 15 Radio FrequencyDevices, and Part 18 Industrial, Scientific, and MedicalEquipment.3. Terminology3.1 Definitions:3
19、.1.1 30-minute Acute Exposure Guideline Levels for Se-lected Airborne Chemicals, (30-min AEGL value),nrepresent threshold exposure limits for the general publicand are applicable to emergency exposure periods for 30minutes.3.1.2 AEGL-1, nairborne concentration (expressed asparts per million (ppm) or
20、 mg/m3) of a substance above whichit is predicted that the general population, including susceptibleindividuals, could experience notable discomfort, irritation, orcertain asymptomatic nonsensory effects. However, the effectsare not disabling and are transient and reversible upon cessa-tion of expos
21、ure.3.1.3 AEGL-2, nairborne concentration (expressed as ppmor mg/m3) of a substance above which it is predicted that thegeneral population, including susceptible individuals, couldexperience irreversible or other serious, long-lasting adversehealth effects or an impaired ability to escape.3.1.4 AEGL
22、-3, nairborne concentration (expressed as ppmor mg/m3) of a substance above which it is predicted that thegeneral population, including susceptible individuals, couldexperience life-threatening health effects or death.3.1.5 alarm, nsound, light, vibration, or data communica-tion signal to the operat
23、or(s), or combinations thereof, indicat-ing that the stationary point chemical vapor detector (SPCVD)has detected the presence of a chemical vapor(s) of interest ator above the alarm threshold value.3.1.6 alarm threshold value, nvapor concentration corre-sponding to an AEGL value (AEGL-1, AEGL-2, or
24、 AEGL-3)that activates an SPCVD alarm.3.1.7 background chemical vapors, nincidental chemicalvapors present in the environment at vapor concentrationslower than the 30-minute AEGL-1 values.3.1.8 consumables, nSPCVD components that requireperiodic replacement.3.1.9 enclosure, nan integral part of the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME29332013STANDARDSPECIFICATIONFORSTATIONARYPOINTCHEMICALVAPORDETECTORSSPCVDFORHOMELANDSECURITYAPPLICATIONS

链接地址:http://www.mydoc123.com/p-532127.html