《ASTM E2919-2014 Standard Test Method for Evaluating the Performance of Systems that Measure Static Six Degrees of Freedom &40 6DOF&41 Pose《测量六自由度 (6DOF) 姿势的系统性能评估的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2919-2014 Standard Test Method for Evaluating the Performance of Systems that Measure Static Six Degrees of Freedom &40 6DOF&41 Pose《测量六自由度 (6DOF) 姿势的系统性能评估的标准试验方法》.pdf(15页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2919 14Standard Test Method forEvaluating the Performance of Systems that Measure Static,Six Degrees of Freedom (6DOF), Pose1This standard is issued under the fixed designation E2919; the number immediately following the designation indicates the year oforiginal adoption or, in the cas
2、e of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 PurposeIn this test method, metrics and proceduresfor collecting and analyzing data to dete
3、rmine the performanceof a pose measurement system in computing the pose (positionand orientation) of a rigid object are provided.1.2 This test method applies to the situation in which boththe object and the pose measurement system are static withrespect to each other when measurements are performed.
4、Vendors may use this test method to establish the performancelimits for their six degrees of freedom (6DOF) pose measure-ment systems. The vendor may use the procedures described in9.2 to generate the test statistics, then apply an appropriatemargin or scaling factor as desired to generate the perfo
5、rmancespecifications. This test method also provides a uniform way toreport the relative or absolute pose measurement capability ofthe system, or both, making it possible to compare theperformance of different systems.1.3 Test LocationThe methodology defined in this testmethod shall be performed in
6、a facility in which the environ-mental conditions are within the pose measurement systemsrated conditions and meet the users requirements.1.4 UnitsThe values stated in SI units are to be regardedas the standard. No other units of measurement are included inthis standard.1.5 This standard does not pu
7、rport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E
8、456 Terminology Relating to Quality and StatisticsE2544 Terminology for Three-Dimensional (3D) ImagingSystems2.2 ASME Standard:3ASME B89.4.19 Performance Evaluation of Laser-BasedSpherical Coordinate Measurement Systems2.3 ISO/IEC Standards:4JCGM 200:2012 International Vocabulary of MetrologyBasic a
9、nd General Concepts andAssociated Terms (VIM),3rd editionJCGM 100:2008 Evaluation of Measurement DataGuideto the Expression of Uncertainty in Measurement (GUM)IEC 60050-300:2001 International ElectrotechnicalVocabularyElectrical and Electronic Measurements andMeasuring Instruments3. Terminology3.1 D
10、efinitions from Other Standards:3.1.1 calibration, noperation that, under specifiedconditions, in a first step, establishes a relation between thequantity values with measurement uncertainties provided bymeasurement standards and corresponding indications withassociated measurement uncertainties and
11、, in a second step,uses this information to establish a relation for obtaining ameasurement result from an indication. JCGM 200:20123.1.1.1 Discussion(1) A calibration may be expressed by a statement, calibra-tion function, calibration diagram, calibration curve, or cali-bration table. In some cases
12、, it may consist of an additive ormultiplicative correction of the indication with associatedmeasurement uncertainty.1This test method is under the jurisdiction of ASTM Committee E57 on 3DImaging Systems and is the direct responsibility of Subcommittee E57.02 on TestMethods.Current edition approved
13、July 1, 2014. Published August 2014. Originallyapproved in 2013. Last previous edition approved in 2013 as E2919-13. DOI:10.1520/E2919-14.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume
14、information, refer to the standards Document Summary page onthe ASTM website.3Available from American Society of Mechanical Engineers (ASME), ASMEInternational Headquarters, Three Park Ave., New York, NY 10016-5990, http:/www.asme.org.4Available from American National Standards Institute (ANSI), 25
15、W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1(2) Calibration should not be confused with either adjust-ment of a measuring system, often mistakenly called “self-calibrat
16、ion,” or verification of calibration.(3) Often, the first step alone in 3.1.1 is perceived as beingcalibration.3.1.2 maximum permissible measurement error, maximumpermissible error, and limit of error, nextreme value ofmeasurement error, with respect to a known reference quantityvalue, permitted by
17、specifications or regulations for a givenmeasurement, measuring instrument, or measuring system.JCGM 200:20123.1.2.1 Discussion(1) Usually, the terms “maximum permissible errors” or“limits of error” are used when there are two extreme values.(2) The term “tolerance” should not be used to designate“m
18、aximum permissible error.”3.1.3 measurand, nquantity intended to be measured.JCGM 200:20123.1.3.1 Discussion(1) The specification of a measurand requires knowledge ofthe kind of quantity; description of the state of thephenomenon, body, or substance carrying the quantity, includ-ing any relevant com
19、ponent; and the chemical entities in-volved.(2) In the second edition of the VIM and IEC 60050-300,the measurand is defined as the “quantity subject to measure-ment.”(3) The measurement, including the measuring system andthe conditions under which the measurement is carried out,might change the phen
20、omenon, body, or substance such thatthe quantity being measured may differ from the measurand asdefined. In this case, adequate correction is necessary.(a) Example 1The potential difference between theterminals of a battery may decrease when using a voltmeterwith a significant internal conductance t
21、o perform the measure-ment. The open-circuit potential difference can be calculatedfrom the internal resistances of the battery and the voltmeter.(b) Example 2The length of a steel rod in equilibriumwith the ambient Celsius temperature of 23C will be differentfrom the length at the specified tempera
22、ture of 20C, which isthe measurand. In this case, a correction is necessary.(4) In chemistry, “analyte,” or the name of a substance orcompound, are terms sometimes used for “measurand.” Thisusage is erroneous because these terms do not refer toquantities.3.1.4 measurement error, error of measurement
23、, and error,nmeasured quantity value minus a reference quantity value.JCGM 200:20123.1.4.1 Discussion(1) The concept of “measurement error” can be used both:(a) When there is a single reference quantity value torefer to, which occurs if a calibration is made by means of ameasurement standard with a
24、measured quantity value havinga negligible measurement uncertainty or if a conventionalquantity value is given, in which case the measurement error isknown, and(b) If a measurand is supposed to be represented by aunique true quantity value or a set of true quantity values ofnegligible range, in whic
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME29192014STANDARDTESTMETHODFOREVALUATINGTHEPERFORMANCEOFSYSTEMSTHATMEASURESTATICSIXDEGREESOFFREEDOM406DOF41POSE

链接地址:http://www.mydoc123.com/p-532105.html