1、Designation: E2904 12Standard Practice forCharacterization and Verification of Phased Array Probes1This standard is issued under the fixed designation E2904; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision
2、. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This standard practice covers measurement proceduresfor evaluating certain characteristics of phased-array ultrasonicprobes that ar
3、e used with phased-array ultrasonic examinationinstrumentation.1.2 This standard practice describes means for obtainingperformance data that may be used to define the acoustic andelectric responses of phased-array ultrasonic probes includingcontact (with or without a wedge) and immersion linearphase
4、d-array probes used for ultrasonic nondestructive testingwith central frequencies ranging from 0.5 MHz to 10 MHz.Frequencies outside of this range may use the same methodsbut the testing equipment may vary.1.3 When ultrasonic values dependent on material are speci-fied in this document, they are bas
5、ed on carbon steel with anultrasonic wave propagation speed of 5920 m/s (650 m/s) forlongitudinal wave modes and 3255 m/s (630 m/s) for trans-verse or shear wave modes.1.4 This document describes the characterization and veri-fication procedures that are to be carried out at the end stage ofthe manu
6、facturing process of phased array probes. This docu-ment does not describe the methods or acceptance criteria usedto verify the performance of the entire phased array ultrasonicinstrument and probe.1.5 The values stated in SI units are to be regarded as thestandard. The values given in parentheses a
7、re for informationonly.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior
8、 to use.2. Referenced Documents2.1 ASTM Standards:2E1065 Guide for Evaluating Characteristics of UltrasonicSearch UnitsE1316 Terminology for Nondestructive Examinations3. Terminology3.1 Definitions:3.1.1 For definitions of terms used in this practice, seeTerminology E1316.3.1.2 Technical Specificati
9、on of the Phased Array Probes:3.1.2.1 datasheetdefined as specification. This is thedocument that defines the general geometry and expectedperformance of a specific model or part number.3.1.2.2 certificationdefined as measured performance ofan individual probe. This is the document that reports them
10、easured performance of a specific probe (specific to a serialnumber).3.1.2.3 probe typecontact or immersion.3.1.2.4 probe shape and sizeprobe form and dimensions.3.1.3 Terminology for Array Probes:3.1.3.1 active aperturepitch times the number of ele-ments.3.1.3.2 cross-couplingalso called “cross-tal
11、k.” An unde-sirable condition where array elements are activated, electri-cally or acoustically, by adjacent elements.3.1.3.3 element widthin a rectangular element, the acous-tic elements short dimension.3.1.3.4 element lengthin a rectangular element, the acous-tic elements long dimension. See passi
12、ve aperture (also calledelement elevation) and Fig. 2.3.1.3.5 element pitch (or pitch)the distance between thecenters of two adjacent array elements.1This practice/guide is under the jurisdiction of ASTM Committee E07 onNondestructive Testing and is the direct responsibility of Subcommittee E07.06 o
13、nUltrasonic Method.Current edition approved Nov. 1, 2012. Published December 2012. DOI:10.1520/E2904-12.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standard
14、s Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.1.3.6 passive aperturethe dimension of an array el-ements length.3.1.3.7 saw cutalso called “kerf,” space or gap. The spacebetween adjacent e
15、lements.3.1.3.8 virtual probea group of individual array elements,pulsed simultaneously or at phasing intervals to generate alarger acoustic aperture.4. Summary of Practice4.1 The physical, acoustic and electrical characteristicswhich can be described from the data obtained by proceduresoutlined in
16、this guide are described as follows.4.2 Physical AspectsIdentification and physical dimen-sion aspects of the probe should be noted. Details to be notedare described in 7.1.4.3 Center Frequency, Bandwidth And Time ResponseSection 7.2 describes procedures for determining centerfrequency, bandwidth an
17、d time response of the individualelements of the linear array probe.4.4 Sensitivity Range Of ElementsSection 7.3 describes aprocedure to determine variation of sensitivity from oneelement to the next based on a fixed input voltage.4.5 Probe SensitivityThe overall sensitivity performanceof all the el
18、ements in the array is assessed in the proceduredescribed in 7.4.4.6 Element CrosstalkA procedure for assessment ofdamping between elements to eliminate crosstalk is provided in7.5.FIG. 1 Schematic Showing Digitization RateE2904 1225. Significance and Use5.1 This standard practice is intended to pro
19、vide standard-ized procedures for evaluating linear phased-array ultrasonicprobes. It is not intended to define performance and acceptancecriteria, but rather to provide data from which such criteria maybe established.FIG. 2 Two-Channel Schematic Showing Measurement Technique for CrosstalkLegend:A =
20、 active aperture (number of active elements x element pitch)H = passive aperturee = element widthp = element pitchg = saw cut between elements (also called kerf or gap)FIG. 3 Schematic of Key Parameters for Linear ArraysE2904 1235.2 Implementation may require more detailed proceduralinstructions in
21、a format of the using facility.5.3 The measurement data obtained may be employed byusers of this guide to specify, describe, or provide performancecriteria for procurement and quality assurance, or serviceevaluation of the operating characteristics of linear phased-array ultrasonic probes. All or po
22、rtions of the standard practicemay be used as determined by the user.5.4 The measurements are made primarily under pulse-echoconditions. To determine the relative performance of a probeelement as either a transmitter or a receiver may requireadditional tests.5.5 While these procedures relate to many
23、 of the significantparameters, others that may be important in specific applica-tions may not be treated. These might include power handlingcapability, breakdown voltage, wear properties of contact units,radio-frequency interference, and the like.5.6 Care must be taken to ensure that comparable meas
24、ure-ments are made and that users of the standard practice followsimilar procedures. The conditions specified or selected (ifoptional) may affect the test results and lead to apparentdifferences.5.7 Interpretation of some test results, such as the shape ofthe frequency response curve, may be subject
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME29042012STANDARDPRACTICEFORCHARACTERIZATIONANDVERIFICATIONOFPHASEDARRAYPROBES 相控阵 探头 表征 验证 标准 实施

链接地址:http://www.mydoc123.com/p-532083.html